Baseline Flatness±0.0010 A, 200 to 800 nm, 1.0 nm SBW, smoothing
Certifications/ComplianceISO 9001:2008
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel, 800 x 480 pixels, 17.8 cm (7 in. diagonal)
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in.)
Spectral BandwidthVariable: 1.0 nm, 2.0 nm
Wavelength Range190 to 1100 nm
Drift<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup
Electrical Requirements100/240 V, 50/60 Hz selected automatically, 150 W maximum
For Use With (Application)Spectroscopy Elemental Isotope Analysis
KeypadSealed membrane
Lamp Life7 years typical
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002 A
ProcessorMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1 to 6000 nm/min. (Variable)
Warranty3 Years
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Weight (Metric)14.4 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Price (USD)
Full specifications
Baseline Flatness±0.0010 A, 200 to 800 nm, 1.0 nm SBW, smoothing
Certifications/ComplianceISO 9001:2008
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel, 800 x 480 pixels, 17.8 cm (7 in. diagonal)
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in.)
Product LineEvolution 260 Bio
Spectral BandwidthVariable: 1.0 nm, 2.0 nm
TypeSpectrophotometer plus Tablet Control Module - US, CAN, JP
Wavelength Range190 to 1100 nm
Drift<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup
Electrical Requirements100/240 V, 50/60 Hz selected automatically, 150 W maximum
KeypadSealed membrane
Lamp Life7 years typical
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignAFBG microcell optimized, AFBG fiber optic optimized, AFBG materials optimized
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002 A
ProcessorMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1 to 6000 nm/min. (Variable)
Warranty3 Years
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Weight (Metric)14.4 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer with Tablet & 1 year Extended Warranty
Price (USD)
Full specifications
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 1 year Extended Warranty
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer with Tablet & 2 year Extended Warranty
Price (USD)
Full specifications
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 2 year Extended Warranty
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer with Tablet & 3 year Extended Warranty
Price (USD)
Full specifications
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 3 year Extended Warranty
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer with 1 year Extended Warranty
Price (USD)
Full specifications
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with 1 year Extended Warranty
Product LineEvolution 260 Bio
TypeUV-Vis Spectrophotometer
Warranty1 Year Extended Warranty
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer with 2 year Extended Warranty
Price (USD)
Full specifications
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with 2 year Extended Warranty
Product LineEvolution 260 Bio
TypeUV-Vis Spectrophotometer
Warranty2 Year Extended Warranty
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Evolution 260 Bio UV-Vis Spectrophotometer with 3 year Extended Warranty
Price (USD)
Full specifications
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with 3 year Extended Warranty
Product LineEvolution 260 Bio
TypeUV-Vis Spectrophotometer
Warranty3 Year Extended Warranty
Unit SizeEach
Showing 8 of 8
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
912A0888Full specifications
EachEvolution 260 Bio Spectrophotometer plus Tablet Control Module - InternationalContact Us ›
Baseline Flatness±0.0010 A, 200 to 800 nm, 1.0 nm SBW, smoothing
Certifications/ComplianceISO 9001:2008
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel, 800 x 480 pixels, 17.8 cm (7 in. diagonal)
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in.)
Spectral BandwidthVariable: 1.0 nm, 2.0 nm
Wavelength Range190 to 1100 nm
Drift<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup
Electrical Requirements100/240 V, 50/60 Hz selected automatically, 150 W maximum
For Use With (Application)Spectroscopy Elemental Isotope Analysis
KeypadSealed membrane
Lamp Life7 years typical
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002 A
ProcessorMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1 to 6000 nm/min. (Variable)
Warranty3 Years
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Weight (Metric)14.4 kg
Unit SizeEach
912A0885Full specifications
EachEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JPContact Us ›
Baseline Flatness±0.0010 A, 200 to 800 nm, 1.0 nm SBW, smoothing
Certifications/ComplianceISO 9001:2008
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - US CAN JP
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel, 800 x 480 pixels, 17.8 cm (7 in. diagonal)
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in.)
Product LineEvolution 260 Bio
Spectral BandwidthVariable: 1.0 nm, 2.0 nm
TypeSpectrophotometer plus Tablet Control Module - US, CAN, JP
Wavelength Range190 to 1100 nm
Drift<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup
Electrical Requirements100/240 V, 50/60 Hz selected automatically, 150 W maximum
KeypadSealed membrane
Lamp Life7 years typical
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignAFBG microcell optimized, AFBG fiber optic optimized, AFBG materials optimized
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002 A
ProcessorMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1 to 6000 nm/min. (Variable)
Warranty3 Years
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Weight (Metric)14.4 kg
Unit SizeEach
912A0885-1YFull specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 1 year Extended WarrantyContact Us ›
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 1 year Extended Warranty
Unit SizeEach
912A0885-2YFull specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 2 year Extended WarrantyContact Us ›
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 2 year Extended Warranty
Unit SizeEach
912A0885-3YFull specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 3 year Extended WarrantyContact Us ›
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with Tablet & 3 year Extended Warranty
Unit SizeEach
840-211000-1YFull specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer with 1 year Extended WarrantyContact Us ›
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with 1 year Extended Warranty
Product LineEvolution 260 Bio
TypeUV-Vis Spectrophotometer
Warranty1 Year Extended Warranty
Unit SizeEach
840-211000-2YFull specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer with 2 year Extended WarrantyContact Us ›
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with 2 year Extended Warranty
Product LineEvolution 260 Bio
TypeUV-Vis Spectrophotometer
Warranty2 Year Extended Warranty
Unit SizeEach
840-211000-3YFull specifications
EachEvolution 260 Bio UV-Vis Spectrophotometer with 3 year Extended WarrantyContact Us ›
DescriptionEvolution 260 Bio UV-Vis Spectrophotometer with 3 year Extended Warranty
Product LineEvolution 260 Bio
TypeUV-Vis Spectrophotometer
Warranty3 Year Extended Warranty
Unit SizeEach
Showing 8 of 8

New sales of this model have been discontinued. Please see the newest models: the Evolution Pro Spectrophotometers.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text