Thermo Scientific™

RapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kits

Catalog number: A33227
Thermo Scientific™

RapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kits

Catalog number: A33227
Rapidly detect and differentiate Salmonella species, Salmonella ser. Typhimurium, and Salmonella ser. Enteritidis in a single test with Thermo Scientific™ RapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kit. Confidently test accuracy and speed up product release with results in as little as 16 to 22 hours and validated workflows for poultry and pork meats, production environment samples and primary production samples. The kits are compatible with the Applied Biosystems™ 7500 Fast Food Safety or Applied Biosystems™ Quant Studio 5 Food Safety Real-Time PCR systems.
 
Catalog Number
A33227
Unit Size
-
For Use With (Equipment)
Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher. A30304 (desktop) A30299 (laptop) Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher. A36320 (desktop) A36328 (laptop) Applied Biosystems™ SimpliAmp™ Thermal Cycler – A24811
Includes
Lysis Reagent, Lysis Tube Caps, Proteinase K, Salmonella Multiplex PCR Tubes, PCR Caps
Price (USD)
Full specifications
DescriptionRapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kit
For Use With (Equipment)Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher. A30304 (desktop) A30299 (laptop) Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher. A36320 (desktop) A36328 (laptop) Applied Biosystems™ SimpliAmp™ Thermal Cycler – A24811
IncludesLysis Reagent, Lysis Tube Caps, Proteinase K, Salmonella Multiplex PCR Tubes, PCR Caps
No. of Tests96 Tests/Kit
Product TypeTyphimurium and Enteritidis Multiplex PCR Kit
Storage RequirementsStore the unopened kit at 2° to 8°C. Store the individual components as indicated on their label.
Detection MethodFluorescence
FormLyophilized Powder
GC-Rich PCR PerformanceHigh
PCR MethodMultiplex PCR
Reaction SpeedFast
Unit Size-
Catalog Number
Unit Size
Each
For Use With (Equipment)

Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.

  • A30304 (desktop)
  • A30299 (laptop)Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher.
  • A36320 (desktop)
  • A36328 (laptop)
Includes
Dynabeads anti-Salmonella, Lysis Buffer, Wash Buffer, Elution Buffer, Proteinase K Buffer, Proteinase K, Salmonella Multiplex PCR Tubes, PCR Caps
Price (USD)
Full specifications
DescriptionRapidFinder Salmonella species, Typhimurium and Enteritidis Multiplex Flex Kit
For Use With (Equipment)

Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.

  • A30304 (desktop)
  • A30299 (laptop)Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher.
  • A36320 (desktop)
  • A36328 (laptop)
IncludesDynabeads anti-Salmonella, Lysis Buffer, Wash Buffer, Elution Buffer, Proteinase K Buffer, Proteinase K, Salmonella Multiplex PCR Tubes, PCR Caps
No. of Tests96 Tests/Kit
Product TypeTyphimurium and Enteritidis Multiplex PCR Kit
Storage RequirementsStore the unopened kit at 2° to 8°C. Store the individual components as indicated on their label
Detection MethodFluorescence
FormLyophilized Powder
GC-Rich PCR PerformanceHigh
PCR MethodMultiplex PCR
Reaction SpeedFast
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeFor Use With (Equipment)IncludesPrice (USD)
A33227Full specifications
-Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher. A30304 (desktop) A30299 (laptop) Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher. A36320 (desktop) A36328 (laptop) Applied Biosystems™ SimpliAmp™ Thermal Cycler – A24811Lysis Reagent, Lysis Tube Caps, Proteinase K, Salmonella Multiplex PCR Tubes, PCR CapsRequest A Quote
DescriptionRapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kit
For Use With (Equipment)Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher. A30304 (desktop) A30299 (laptop) Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher. A36320 (desktop) A36328 (laptop) Applied Biosystems™ SimpliAmp™ Thermal Cycler – A24811
IncludesLysis Reagent, Lysis Tube Caps, Proteinase K, Salmonella Multiplex PCR Tubes, PCR Caps
No. of Tests96 Tests/Kit
Product TypeTyphimurium and Enteritidis Multiplex PCR Kit
Storage RequirementsStore the unopened kit at 2° to 8°C. Store the individual components as indicated on their label.
Detection MethodFluorescence
FormLyophilized Powder
GC-Rich PCR PerformanceHigh
PCR MethodMultiplex PCR
Reaction SpeedFast
Unit Size-
A33227KFFull specifications
Each

Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.

  • A30304 (desktop)
  • A30299 (laptop)Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher.
  • A36320 (desktop)
  • A36328 (laptop)
Dynabeads anti-Salmonella, Lysis Buffer, Wash Buffer, Elution Buffer, Proteinase K Buffer, Proteinase K, Salmonella Multiplex PCR Tubes, PCR CapsRequest A Quote
DescriptionRapidFinder Salmonella species, Typhimurium and Enteritidis Multiplex Flex Kit
For Use With (Equipment)

Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.Applied Biosystems™ 7500 Fast Food Safety Real-Time PCR Instrument with Applied Biosystems™ RapidFinder™ Express Software v2.0 or higher.

  • A30304 (desktop)
  • A30299 (laptop)Applied Biosystems™ QuantStudio 5 (0.1 ml) Food Safety Real-Time PCR Instrument with Thermo Scientific™ RapidFinder™ Analysis Software v1.1 or higher.
  • A36320 (desktop)
  • A36328 (laptop)
IncludesDynabeads anti-Salmonella, Lysis Buffer, Wash Buffer, Elution Buffer, Proteinase K Buffer, Proteinase K, Salmonella Multiplex PCR Tubes, PCR Caps
No. of Tests96 Tests/Kit
Product TypeTyphimurium and Enteritidis Multiplex PCR Kit
Storage RequirementsStore the unopened kit at 2° to 8°C. Store the individual components as indicated on their label
Detection MethodFluorescence
FormLyophilized Powder
GC-Rich PCR PerformanceHigh
PCR MethodMultiplex PCR
Reaction SpeedFast
Unit SizeEach
Showing 2 of 2

Increase your workflow efficiency while meeting regulatory requirements to detect the most common Salmonella serovars which cause disease in humans with the RapidFinder Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kit. The real-time PCR kit enables rapid, simultaneous detection and presumptive identification of Salmonella species, Salmonella Typhimurium, and Salmonella Enteritidis in a single well, with ISO 16140-2 and AOAC-RI validated workflows on a range of matrices including raw and ready-to-eat poultry and pork meat, food production environment samples, and samples from primary production.

  • Faster decisions: earlier product release (negative results) and quicker interventions (positive results) due to simultaneous detection (three tests in one) and a reduced time-to-result compared with culture methods.
  • Cost reductions: up to 50% consumable cost savings compared with running individual PCR tests for Salmonella species, Salmonella Typhimurium, and Salmonella
  • Increased efficiency: save valuable technician time with single, non-proprietary enrichment, ready-to-use reagents, simple sample preparation, and simultaneous identification.
  • Confident results: Applied Biosystems™ TaqMan™ Real-Time PCR probes provide a high level of specificity and sensitivity for industry-relevant serovars. Internal amplification controls give added confidence.
  • Convenience: part of a range of end-to-end (enrichment to confirmation) testing solutions including all microbiology reagents and instruments, along with dedicated technical support worldwide. 

RapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex PCR Kit includes:

  • Pre-dispensed and ready-to-use reagents for cell lysis and release of DNA from bacteria present in enriched food and environmental samples.
  • Pre-dispensed lyophilized PCR pellets containing target-specific primers, probes, Internal Positive Control (IPC), and reagents for multiplex real-time PCR using the prepared lysate.

RapidFinder™ Salmonella Species, Typhimurium and Enteritidis Multiplex Flex Kit includes:

    For testing of Food and Environmental samples only.

    Figures

    Frequently asked questions (FAQs)

    Citations & References