Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Easily transport and install the real-time, ambient Thermo Scientific™ ADR1500 Area Dust Monitor for continuous monitoring.
Flow Rate | 1.0 to 3.5 L/min. |
Temperature (English) Operating | 14°F to 122°F |
Temperature (Metric) Operating | 10°C to 50°C |
2-sigma Values | ±0.5% of reading or ±0.0015mg/m3, whichever is larger, for 10-second averaging time |
Accuracy | ±5% of reading ±precision) traceable to SAE Fine test dust |
Aerodynamic Particle Cut-Point Range | 1.0 to 10 μm, with optional cyclone accessories |
Alarm Averaging Time | Real-time (1 to 60 seconds) or STEL (15 minutes) |
Alarms | Load impedance >100kw , Alarm ON = short to ground, Alarm OFF = open |
Certifications/Compliance | UKCA |
Concentration Measurement Range | 0.001 to 400mg/m³ (auto-ranging) |
Data Logging Averaging Periods | 1 second to 1hour |
Depth (English) | 17 in. |
Depth (Metric) | 215 mm |
Description | Area Dust Monitor |
Frequency | 50/60 Hz |
Height (English) | 21 in. |
Height (Metric) | 431 mm |
Optional Cyclones | GK 2.05 (Red) primarily for PM4 through PM10, SCC 1.062 (blue) primarily for PM1 through PM4 |
Particle Size Range | 0.1 to 10µm |
Precision | ±2%, for 1-second averaging time |
Real-time Analog Signal | 0 to 2V and 4 to 20mA, with selectable full scale ranges between 0.1 and 400mg/m3; 0-0.1, 0-0.4, 0-1.0, 0-4.0, 0-10, 0-40, 0-100 and 0-400, mg/m3 |
Real-time Digital Signal | Concentration, flow, temperature, relative humidity, barometric pressure, time, date |
Repeatability | ±0.005mg/m3, for 1-second averaging time |
Resolution | 0.1μg/m3 |
RH correction | ±0.2% or reading or ±0.0005mg/m3, whichever is larger, for 60-second averaging time |
Run Summary | Site number, average and max. concentrations, time/date of maximum, number of logged points, start time/date, elapsed time (run duration), averaging (logging) period, calibration factor and tag number |
Scattering Coefficient Range | 1.1 x 10-6 to 0.6m-1 (approximately) @ l = 880nm |
Serial Interface | High speed, USB/RS-232 (reserved for wireless applications), 19,200 baud |
Voltage | 100/240 VAC, 12/24 VDC for solar or auxiliary battery options |
Weight (English) | 28.5 lb. |
Weight (Metric) | 12.9 kg |
Width (English) | 17 in. |
Width (Metric) | 431 mm |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
ADR1500 | Each | Area Dust Monitor | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The Thermo Scientific Model ADR1500 Dust Monitor utilizes the highly sensitive light-scattering photometer (nephelometer) technology as used in the Thermo Scientific™ pDR series. The intensity of the light scattered by airborne particles passing through the sensing chamber is linearly proportional to their concentration. This optical configuration produces optimal response to particles, providing continuous measurements of the concentrations of airborne particles for total particulate and cut-points ranging from PM10 down to PM1.
The ADR1500 incorporates a temperature and relative humidity (RH) sensor coupled with an internal heater to mitigate the positive bias with elevated ambient RH. Additionally, the flow control is truly volumetric and is maintained through digital feedback of the onboard barometric pressure sensor, temperature sensor and calibrated differential pressure across a precision orifice. The principles of true volumetric flow, as incorporated by the ADR1500, result in an accurate sample volume and precise particle cut-point.
Key Features:
Additional Information:
Recommended for: