Search Thermo Fisher Scientific
Search Thermo Fisher Scientific
Maximize high-throughput performance in proteomics and biopharma applications with the Thermo Scientific Orbitrap Exploris 480 mass spectrometer. Where next level exploration delivers quantifiable accuracy, and selectivity required to obtain richer insights. Empowering translational scientists by bringing performance and intelligence together, the switch between exploration and targeted quantitation has never been easier. Suddenly your work goes deeper and even the routine will become simple, certain and extraordinary.
Type | Orbitrap LC-MS |
Dynamic Range | >5000:1 within one spectrum |
Mass Range | 40 to 6000 m/z |
Mass Accuracy | <3 ppm RMS – with internal calibration |
Resolution | 480,000 at m/z 195 |
Scan Rates | Up to 40 Hz at resolution setting of 7500 at m/z 200 |
Analog Inputs | One (1) analog input (0-1 V), One (1) analog (0-10 V) |
Polarity Switching | One Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 60000) |
Sensitivity | MS/MS: 50 fg Reserpine on Column S/N 100:1, SIM: 50 fg Reserpine on Column S/N 150:1 |
Description | Orbitrap Exploris 480 MS with EASY-IC (internal calibration) |
Weight (Metric) | 120 kg (265 lb.) without data system, vacuum rough pumps and optional items |
Unit Size | Each |
Type | Orbitrap LC-MS |
Dynamic Range | >5000:1 within one spectrum |
Mass Range | 40 to 8000 m/z |
Mass Accuracy | <3 ppm RMS – with external calibration over 24 h and without any kind of mass recalibration |
Scan Rates | Up to 40 Hz at resolution setting of 7500 at m/z 200 |
Analog Inputs | One (1) analog input (0-1 V), One (1) analog (0-10 V) |
Polarity Switching | One Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 60000) |
Sensitivity | MS/MS: 50 fg Reserpine on Column S/N 100:1, SIM: 50 fg Reserpine on Column S/N 150:1 |
Description | Orbitrap Exploris 480 MS with BioPharma option (factory installed) |
Weight (Metric) | 120 kg (265 lb.) without data system, vacuum rough pumps and optional items |
Max. Resolution | Up to 480,000 at m/z 200 |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Mass Range | Price (USD) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
BRE725533 | Each | Orbitrap Exploris 480 MS with EASY-IC (internal calibration) | 40 to 6000 m/z | Request A Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
BRE725539 | Each | Orbitrap Exploris 480 MS with BioPharma option (factory installed) | 40 to 8000 m/z | Request A Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Maximum data certainty
Market leading resolution & mass accuracy, selectivity & spectral quality to solve the most complex challenges.
Robustness and reliability
Makes large scale studies possible and reduces everyday hassle. It just works!
Empowers more users
Transition each experimental step to the next level with intelligence-driven performance.
High resolution within a compact footprint
Because space is always a premium regardless of lab.
Orbitrap power now for isotope ratios
Open new dimensions in isotope ratio analysis with Thermo Scientific™ Orbitrap Exploris™ Isotope Solutions.
Preserve intramolecular isotopic information throughout the analysis and determine previously inaccessible isotopologues by the combination of soft electrospray ionization (ESI) and high-resolution accurate mass (HRAM) sensitivity.