Thermo Scientific™

FHT 3511 Positron Stack Monitors

Catalog number: FHT3511C
Thermo Scientific™

FHT 3511 Positron Stack Monitors

Catalog number: FHT3511C

Thermo Scientific™ FHT 3511 Positron Stack Monitor is a stack monitoring detector designed specifically for positron emitters (PET effluents) for indoor and outdoor use. A unique stack monitor using coincidence counting and large area plastic scintillation detector to ensure excellent geometrical efficiency and reduced sensitivity to ambient gamma radiation.

 
Catalog Number
FHT3511C
Unit Size
Each
Description
Effluent monitor for 20 in. D exhaust air pipe
Price (USD)
Full specifications
TypePositron Stack Monitor
Diameter (Metric) Detector Window508mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 20 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)43.3 cm
Height (Metric)110 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)38.4 in.
Width (Metric)97.5 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Effluent monitor for 16 in. D exhaust air pipe
Price (USD)
Full specifications
TypePositron Stack Monitor
Diameter (Metric) Detector Window406mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 16 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)35.4 in.
Height (Metric)90 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)30.3 in.
Width (Metric)77 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Effluent monitor for 12 in. D exhaust air pipe
Price (USD)
Full specifications
TypePositron Stack Monitor
Diameter (Metric) Detector Window305mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 12 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)35.4 in.
Height (Metric)90 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)30.3 in.
Width (Metric)77 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Effluent monitor for 24 in. D exhaust air pipe
Price (USD)
Full specifications
TypePositron Stack Monitor
Diameter (Metric) Detector Window610mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 24 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)43.3 cm
Height (Metric)110 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)38.4 in.
Width (Metric)97.5 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
FHT3511CFull specifications
EachEffluent monitor for 20 in. D exhaust air pipeRequest A Quote
TypePositron Stack Monitor
Diameter (Metric) Detector Window508mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 20 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)43.3 cm
Height (Metric)110 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)38.4 in.
Width (Metric)97.5 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
FHT3511BFull specifications
EachEffluent monitor for 16 in. D exhaust air pipeRequest A Quote
TypePositron Stack Monitor
Diameter (Metric) Detector Window406mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 16 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)35.4 in.
Height (Metric)90 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)30.3 in.
Width (Metric)77 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
FHT3511Full specifications
EachEffluent monitor for 12 in. D exhaust air pipeRequest A Quote
TypePositron Stack Monitor
Diameter (Metric) Detector Window305mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 12 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)35.4 in.
Height (Metric)90 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)30.3 in.
Width (Metric)77 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
FHT3511DFull specifications
EachEffluent monitor for 24 in. D exhaust air pipeRequest A Quote
TypePositron Stack Monitor
Diameter (Metric) Detector Window610mm
Alpha/Beta/Gamma MeasurementGamma Measurement
DescriptionEffluent monitor for 24 in. D exhaust air pipe
Detector TypePlastic Scintillation
Display TypeTFT-Display
Height (English)43.3 cm
Height (Metric)110 cm
Depth (English)39.4 in.
Depth (Metric)100 cm
Measuring Range1 to 100.000kBq/m3
Radiation TypeGamma
Sensitivity1-100.000kBq/m3
Ambient Temperature15 to 45°C
Weight (English)551 lb.
Weight (Metric)250 kg
Width (English)38.4 in.
Width (Metric)97.5 cm
ApplicationsPet-Nuclide Monitoring
IncludesFHT 8000 software operable under Windows
Voltage230V
Unit SizeEach
Showing 4 of 4
Measures 511 keV annihilation photons to determine the concentration of positrons in the duct or stack. With each radioactive decay, F-18 or other, PET-nuclides emit a positron which annihilates via the simultaneous emission of two 511keV gamma quanta under 180°.
  • Extremely low coincidence background
  • Signal-to-background ratio enhanced between 1 and 2 orders of magnitude (as compared to standard counting systems)
  • Detection limits well below 1 kBq/m3
  • Total rejection of gammas from outside the active detection volume
  • No lead shielding necessary
  • Easy calibration using a point source (i.e. Ge-68) on the outer surface of the duct
  • Large scintillation detectors are mounted outside the stack
  • Versatile Windows based software for operation and report generation
  • Graphic display of last 24 hours/6 days
  • Immediate alarm generation
  • Optional DDE exchange with monitoring program
  • Optional data export to spread sheet program
  • Optional advanced long term data storage and display program “NetView”
  • Sturdy aluminum frame
  • Stainless steel fittings
  • Corrosion free
  • Suitable for indoor and outdoor applications
  • White, UV-stabilized PVC cover panels with increased impact strength
  • Variable height with easily adjustable feet

Includes:

FHT 8000 software operable under Windows

Figures

Frequently asked questions (FAQs)