Thermo Scientific™

Helix MC Plus™ Multicollector Noble Gas Mass Spectrometer

Catalog number: IQLAAEGACVFAKUMAWL
Thermo Scientific™

Helix MC Plus™ Multicollector Noble Gas Mass Spectrometer

Catalog number: IQLAAEGACVFAKUMAWL
Measure any five isotopes of neon, argon, krypton or xenon simultaneously at new levels of resolution with the Thermo Scientific™ Helix MC Plus™ multicollector noble gas mass spectrometer, the ultimate noble gas solution. Its high-resolution magnetic sector analyzer with 35 cm, 120 degree extended geometry ion optics make it the most advanced static vacuum mass spectrometer (SVMS) for the isotopic analysis of small samples of the noble gases.
 
Catalog Number
IQLAAEGACVFAKUMAWL
Unit Size
Each
Sensitivity
Helium: = 2 x 10-4 Amp/Torr @ ≤ 1.2 mA Source, 9.9 kV; Argon: = 1 x 10-3 Amp/Torr @ ≤ 1.0 mA Source, 9.9 kV
Price (USD)
Full specifications
Abundance Sensitivity<1ppm for adjacent masses sensitivity (39Ar contribution from 40Ar) at a pressure of 1 × 107mbar
TypeNoble Gas MS
Axial ResolutionFor Faraday/ion counting CFM = 750 at 10% peak valley; For Hi-Res Faraday/ion counting CFM = 1,500 at 10% peak valley
Background≤1 x 10-13 cc STP(at m/z 36Ar)
Item DescriptionHelix MC Plus Multicollector Noble Gas Mass Spectrometer
Mass RangeHe, Ne, Ar: 9.9 kV Acceleration Voltage; Kr, Xe: Lower Acceleration Voltage
Peak Side Stabilitym/z 40Ar: ≤±50ppm/30 min.
Rate of Riseat 40Ar ≤2 x 10-12 cc STP/Min of 30 Min.
SensitivityHelium: = 2 x 10-4 Amp/Torr @ ≤ 1.2 mA Source, 9.9 kV; Argon: = 1 x 10-3 Amp/Torr @ ≤ 1.0 mA Source, 9.9 kV
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeSensitivityPrice (USD)
IQLAAEGACVFAKUMAWLFull specifications
EachHelium: = 2 x 10-4 Amp/Torr @ ≤ 1.2 mA Source, 9.9 kV; Argon: = 1 x 10-3 Amp/Torr @ ≤ 1.0 mA Source, 9.9 kVRequest A Quote
Abundance Sensitivity<1ppm for adjacent masses sensitivity (39Ar contribution from 40Ar) at a pressure of 1 × 107mbar
TypeNoble Gas MS
Axial ResolutionFor Faraday/ion counting CFM = 750 at 10% peak valley; For Hi-Res Faraday/ion counting CFM = 1,500 at 10% peak valley
Background≤1 x 10-13 cc STP(at m/z 36Ar)
Item DescriptionHelix MC Plus Multicollector Noble Gas Mass Spectrometer
Mass RangeHe, Ne, Ar: 9.9 kV Acceleration Voltage; Kr, Xe: Lower Acceleration Voltage
Peak Side Stabilitym/z 40Ar: ≤±50ppm/30 min.
Rate of Riseat 40Ar ≤2 x 10-12 cc STP/Min of 30 Min.
SensitivityHelium: = 2 x 10-4 Amp/Torr @ ≤ 1.2 mA Source, 9.9 kV; Argon: = 1 x 10-3 Amp/Torr @ ≤ 1.0 mA Source, 9.9 kV
Unit SizeEach
Showing 1 of 1
Advanced Noble Gas Solution
  • Resolve many hydrocarbon interferences with the standard resolution detector (>750 @ 10% peak valley), or chose the optional high-resolution detector for even greater clarity (>1500 @ 10% peak valley)
  • Reduce analysis times and increase productivity through the simultaneous measurement of up to five isotopes; no peak jumping required
  • Gain ultra-high-resolution from the large-radius ion optics geometry combined with innovative ion optical elements
  • Improve accuracy with incredible levels of sensitivity, enabled by a new X- & Z-focused Nier-type bright source
  • Easily measure peak jumps when needed (e.g. helium isotopes)
  • Enable the measurement of a wide and dynamic range of sample concentrations via the highly advanced, combined Faraday multiplier (CFM) detector
  • Conduct the majority of analyses on long-life Faraday detectors thanks to amplifier innovations
Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.