Thermo Scientific™

NanoDrop™ Lite Spectrophotometer

Catalog number: ND-LITE
Thermo Scientific™

NanoDrop™ Lite Spectrophotometer

Catalog number: ND-LITE
New sales of this product have been discontinued. Please see the newest model: NanoDrop Lite Plus Spectrophotometer.
 
Catalog Number
ND-LITE
Unit Size
Each
Includes
Without Printer
Price (USD)
Full specifications
Absorbance Accuracy0.03
Absorbance Range0 to 30 A
Certifications/ComplianceUL/CSA and CE
CompatibilityLocal Control Only
Detection Limits0.12 mg/mL to 45 mg/mL (BSA), 4 ng/μ
Detector TypeSilicon Photodiode
DisplayLCD
Light SourceLED
Product LineNanoDrop Lite
TypeUV-Vis Spectrophotometer
Voltage6 V
Footprint16 x 11.5 cm
For Use With (Application)Nucleic acid, protein A280
IncludesWithout Printer
Measurement Time<5 sec.
No. of Samples1
Pathlength0.5 mm
Sample Volume (Metric)1 to 2 μL
Spectral Resolution<8.0 nm
Volume (Metric)1 μL
Warranty1 year parts and labor
Wattage18 W
Wavelength Repeatability0.002 *SD of 10 individual measurements at 0.74 Abs
Weight (Metric)0.8 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Includes
Printer
Price (USD)
Full specifications
Absorbance Accuracy0.03
Absorbance Range0 to 30 A
Certifications/ComplianceUL/CSA and CE
CompatibilityLocal Control Only
Concentration1500 ng/μL (dsDNA); 45 mg/mL (BSA)
ConnectionsUSB
Depth (Metric)11.5 cm
Detection Limits0.12 mg/ml (BSA), 4 ng/μ/ (dsDNA)
Detector TypeSilicon Photodiode
DisplayLCD
Light SourceLED
Product LineNanoDrop Lite
TypeUV-Vis Spectrophotometer with Printer
Voltage6 V
Wavelength Range260 to 280 nm
Footprint16 x 11.5 cm
For Use With (Application)Nucleic Acid Quantification, DNA Quantification, RNA Quantification, Protein Quantification
IncludesPrinter
Material303 stainless steel; quartz fiber
Measurement Time<5 sec.
Min. Data Interval4 ng/μL (dsDNA); 45 mg/mL (BSA)
No. of Samples1
Pathlength0.5 mm
Resolution<8nm
Sample Volume (Metric)1 to 2 μL
Spectral Resolution8.0 nm
Volume (Metric)1 μL
Warranty1 year parts and labor
Wattage18 W
Wavelength Repeatability0.002 (10 individual measurements at 0.74 Abs)
Weight (Metric)0.8 kg
Width (Metric)16 cm
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeIncludesPrice (USD)
ND-LITEFull specifications
EachWithout PrinterContact Us ›
Absorbance Accuracy0.03
Absorbance Range0 to 30 A
Certifications/ComplianceUL/CSA and CE
CompatibilityLocal Control Only
Detection Limits0.12 mg/mL to 45 mg/mL (BSA), 4 ng/μ
Detector TypeSilicon Photodiode
DisplayLCD
Light SourceLED
Product LineNanoDrop Lite
TypeUV-Vis Spectrophotometer
Voltage6 V
Footprint16 x 11.5 cm
For Use With (Application)Nucleic acid, protein A280
IncludesWithout Printer
Measurement Time<5 sec.
No. of Samples1
Pathlength0.5 mm
Sample Volume (Metric)1 to 2 μL
Spectral Resolution<8.0 nm
Volume (Metric)1 μL
Warranty1 year parts and labor
Wattage18 W
Wavelength Repeatability0.002 *SD of 10 individual measurements at 0.74 Abs
Weight (Metric)0.8 kg
Unit SizeEach
ND-LITE-PRFull specifications
EachPrinterContact Us ›
Absorbance Accuracy0.03
Absorbance Range0 to 30 A
Certifications/ComplianceUL/CSA and CE
CompatibilityLocal Control Only
Concentration1500 ng/μL (dsDNA); 45 mg/mL (BSA)
ConnectionsUSB
Depth (Metric)11.5 cm
Detection Limits0.12 mg/ml (BSA), 4 ng/μ/ (dsDNA)
Detector TypeSilicon Photodiode
DisplayLCD
Light SourceLED
Product LineNanoDrop Lite
TypeUV-Vis Spectrophotometer with Printer
Voltage6 V
Wavelength Range260 to 280 nm
Footprint16 x 11.5 cm
For Use With (Application)Nucleic Acid Quantification, DNA Quantification, RNA Quantification, Protein Quantification
IncludesPrinter
Material303 stainless steel; quartz fiber
Measurement Time<5 sec.
Min. Data Interval4 ng/μL (dsDNA); 45 mg/mL (BSA)
No. of Samples1
Pathlength0.5 mm
Resolution<8nm
Sample Volume (Metric)1 to 2 μL
Spectral Resolution8.0 nm
Volume (Metric)1 μL
Warranty1 year parts and labor
Wattage18 W
Wavelength Repeatability0.002 (10 individual measurements at 0.74 Abs)
Weight (Metric)0.8 kg
Width (Metric)16 cm
Unit SizeEach
Showing 2 of 2
The NanoDrop Lite performs basic microvolume measurements. Its compact design, with built-in controls and software, make the NanoDrop Lite small enought to fit on any benchtop. The patented sample retention system allows sample to be pipetted directly onto the optical measurement surface. After measurement the sample is wiped off the measurement surface with a lint free lab wipe.
  • Measures nucleic acid concentration at 260nm and purity using the 260/280 ratio
  • Measures purified protein concentration at 280nm
  • Employs the unique NanoDrop microvolume sampling technology
  • Delivers the accuracy and reproducibility expected from NanoDrop instruments
  • Uses built-in controls and software–no computer required
  • Optional accessory printer for cryogenic labels available