Thermo Scientific™

PXS5-925/PXS5-925-RR MicroFocus 90kV X-Ray Source

Catalog number: PXS5925RR
Thermo Scientific™

PXS5-925/PXS5-925-RR MicroFocus 90kV X-Ray Source

Catalog number: PXS5925RR
The Thermo Scientific™ PXS5-925 is a 90kV microfocus X-Ray source for use in high-resolution imaging applications. The small spot size and high magnification, combined with stable output allow superior quality 2D and 3D images.
 
Catalog Number
PXS5925RR
Unit Size
Each
Description
MicroFocus X-Ray Source 90kV
Price (USD)
Full specifications
Detector TypeX-Ray
Radiation TypeX-Ray Tube
Sensitivity250 fA/μSvh-1
TypeX-Ray Source
Cone of Illumination40° round beam
Window MaterialBeryllium
Power Consumption4 amps
DescriptionMicroFocus X-Ray Source 90kV
Diameter (English) Window0.37 in.
Diameter (Metric) Window9.4 mm
Humidity Range0 to 95%, up to 5000 feet
Max. Beam Current0.178mA at 45kV
Max. Power8w (45 to 90kV)
Operating Voltage Range20 to 90kV
Shielding TypeX-Ray leakage behind the X-Ray tube is less than 0.5mR/hour, measured one inch away with Victoreen 190.
Spot Elipticity±20% @ 8 watts, 90kV (either axis referred to average)
Spot to Window Spacing12 ± 0.5mm
Target MaterialTungsten
Temperature (Metric) Operating0°C to 32°C
Thickness (English) Window0.005 in.
Thickness (Metric) Window0.127 mm
Weight (English)8 lb.
Weight (Metric)3.6 kg
Spot Size≤ 9μ at 4 watts (45 to 90kV), ≤14μ at 8 watts (45 to 90kV)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
MicroFocus X-Ray Source 90 kV
Price (USD)
Full specifications
Detector TypeX-Ray Tube
Radiation TypeX-Ray
TypeX-Ray Source
Cone of Illumination40° round beam
Window MaterialBeryllium
Power Consumption4 amps
DescriptionMicroFocus X-Ray Source 90 kV
Diameter (English) Window0.37 in.
Diameter (Metric) Window9.4 mm
Humidity Range0 to 95%, up to 5000 feet
Max. Beam Current0.178mA at 45kV
Max. Power8w (45 to 90kV)
Operating Voltage Range20 to 90kV
Shielding TypeX-Ray leakage behind the X-Ray tube is less than 0.5mR/hour, measured one inch away with Victoreen 190.
Spot Elipticity±20% @ 8 watts, 90kV (either axis referred to average)
Spot to Window Spacing12 ± 0.5mm
Target MaterialTungsten
Temperature (Metric) Operating0°C to 32°C
Thickness (English) Window0.005 in.
Thickness (Metric) Window0.127 mm
Weight (English)8 lb.
Weight (Metric)3.6 kg
Spot Size≤ 7μ at 4 watts (45 to 90kV), ≤ 9μ at 8 watts (45 to 90kV)
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
PXS5925RRFull specifications
EachMicroFocus X-Ray Source 90kVRequest A Quote
Detector TypeX-Ray
Radiation TypeX-Ray Tube
Sensitivity250 fA/μSvh-1
TypeX-Ray Source
Cone of Illumination40° round beam
Window MaterialBeryllium
Power Consumption4 amps
DescriptionMicroFocus X-Ray Source 90kV
Diameter (English) Window0.37 in.
Diameter (Metric) Window9.4 mm
Humidity Range0 to 95%, up to 5000 feet
Max. Beam Current0.178mA at 45kV
Max. Power8w (45 to 90kV)
Operating Voltage Range20 to 90kV
Shielding TypeX-Ray leakage behind the X-Ray tube is less than 0.5mR/hour, measured one inch away with Victoreen 190.
Spot Elipticity±20% @ 8 watts, 90kV (either axis referred to average)
Spot to Window Spacing12 ± 0.5mm
Target MaterialTungsten
Temperature (Metric) Operating0°C to 32°C
Thickness (English) Window0.005 in.
Thickness (Metric) Window0.127 mm
Weight (English)8 lb.
Weight (Metric)3.6 kg
Spot Size≤ 9μ at 4 watts (45 to 90kV), ≤14μ at 8 watts (45 to 90kV)
Unit SizeEach
PXS5925Full specifications
EachMicroFocus X-Ray Source 90 kVRequest A Quote
Detector TypeX-Ray Tube
Radiation TypeX-Ray
TypeX-Ray Source
Cone of Illumination40° round beam
Window MaterialBeryllium
Power Consumption4 amps
DescriptionMicroFocus X-Ray Source 90 kV
Diameter (English) Window0.37 in.
Diameter (Metric) Window9.4 mm
Humidity Range0 to 95%, up to 5000 feet
Max. Beam Current0.178mA at 45kV
Max. Power8w (45 to 90kV)
Operating Voltage Range20 to 90kV
Shielding TypeX-Ray leakage behind the X-Ray tube is less than 0.5mR/hour, measured one inch away with Victoreen 190.
Spot Elipticity±20% @ 8 watts, 90kV (either axis referred to average)
Spot to Window Spacing12 ± 0.5mm
Target MaterialTungsten
Temperature (Metric) Operating0°C to 32°C
Thickness (English) Window0.005 in.
Thickness (Metric) Window0.127 mm
Weight (English)8 lb.
Weight (Metric)3.6 kg
Spot Size≤ 7μ at 4 watts (45 to 90kV), ≤ 9μ at 8 watts (45 to 90kV)
Unit SizeEach
Showing 2 of 2
Thermo Scientific PXS5-925 X-Ray sources offer many attractive benefits:
  • Small, round spot optimized over the range of operating voltage and power for distortion free images
  • 12mm spot-to-window spacing for high geometric magnification and high resolution
  • X-Ray tube, power supply, and control electronics in one compact package make system integration easy
  • Highly stable spot location and flux for consistent image quality in Micro-CT applications

Recommended for:

  • Manual inspection of printed circuit boards and electronic devices
  • Nondestructive test requiring high-resolution imaging of metal and plastic parts
  • Micro-CT imaging for industrial and life sciences applications
  • Rotating gantry Micro-CT systems (Thermo Scientific PXS5-925-RR)

Figures