Thermo Scientific™

Orion™ pHR Process ROSS™ Electrode

Catalog number: SBPHR-3
Thermo Scientific™

Orion™ pHR Process ROSS™ Electrode

Catalog number: SBPHR-3

Save time and money while achieving fast, accurate measurements in a variety of samples with the Thermo Scientific™ Orion™ pHR Process ROSS™ Electrode. With minimal maintenance and a longer lifetime, this product offers superior performance, reliability and longevity for a variety of applications, including pure water. The double junction design with replaceable salt bridge lengthens electrode life providing better value. When performance starts to degrade, simply remove and replace the old salt bridge and electrolyte to rejuvinate response.

 
Catalog Number
SBPHR-3
Unit Size
Each
Description
pHR Salt Bridge, Quantity: 3
Price (USD)
Availability
-
Full specifications
Quantity
-
DescriptionpHR Salt Bridge, Quantity: 3
TypeSalt Bridge
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
pHR Reference Fill Solution Bridge
Price (USD)
Availability
-
Full specifications
Quantity
-
DescriptionpHR Reference Fill Solution Bridge
TypeFill Solution Bridge
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
pHR Salt Bridge, Quantity: 1
Price (USD)
Availability
-
Full specifications
Quantity
-
DescriptionpHR Salt Bridge, Quantity: 1
TypeSalt Bridge
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
pHR Reference Fill Solution Bridge, without pre-amplifier; 15 ft. cable
Price (USD)
Availability
-
Full specifications
Quantity
-
DescriptionpHR Reference Fill Solution Bridge, without pre-amplifier; 15 ft. cable
TypeFill Solution Bridge
Includeswithout pre-amplifier; 15 ft. cable
Length (English) Cable15 ft.
Length (Metric) Cable4.57 m
Max. Flow Rate10 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
Catalog Number
Unit Size
Each
Description
pHR Reference Fill Solution Bridge, with pre-amplifier; 10 ft. cable
Price (USD)
Price: 938.00
Your price:
Availability
-
Full specifications
Quantity
ContainsPre-amplifier
DescriptionpHR Reference Fill Solution Bridge, with pre-amplifier; 10 ft. cable
TypeFill Solution Bridge with Pre-amplifier
Includeswith pre-amplifier; 10 ft. cable
Length (English) Cable10 ft.
Length (Metric) Cable4.57 m
Max. Flow Rate3.05 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
For Use With (Equipment)pHR process ROSS electrode
Unit SizeEach
Catalog Number
Unit Size
Each
Description
pHR Reference Fill Solution Bridge, with pre-amplifier; 20 ft. cable
Price (USD)
Price: 1,050.00
Your price:
Availability
-
Full specifications
Quantity
ContainsPre-amplifier
DescriptionpHR Reference Fill Solution Bridge, with pre-amplifier; 20 ft. cable
TypeFill Solution Bridge with Pre-amplifier
Includeswith pre-amplifier; 20 ft. cable
Length (English) Cable20 ft.
Length (Metric) Cable6.1 m
Max. Flow Rate3.05 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
For Use With (Equipment)pHR process ROSS electrode
Unit SizeEach
Catalog Number
Unit Size
Each
Description
pHR Reference Fill Solution Bridge, with pre-amplifier; 30 ft. cable
Price (USD)
Price: 1,130.00
Your price:
Availability
-
Full specifications
Quantity
ContainsPre-amplifier
DescriptionpHR Reference Fill Solution Bridge, with pre-amplifier; 30 ft. cable
TypeFill Solution Bridge with Pre-amplifier
Includeswith pre-amplifier; 30 ft. cable
Length (English) Cable30 ft.
Length (Metric) Cable6.1 m
Max. Flow Rate9.1 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
Showing 7 of 7
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)AvailabilityQuantity
SBPHR-3Full specifications
EachpHR Salt Bridge, Quantity: 3Request A Quote--
DescriptionpHR Salt Bridge, Quantity: 3
TypeSalt Bridge
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
RCPHR-60Full specifications
EachpHR Reference Fill Solution BridgeRequest A Quote--
DescriptionpHR Reference Fill Solution Bridge
TypeFill Solution Bridge
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
SBPHR-1Full specifications
EachpHR Salt Bridge, Quantity: 1Request A Quote--
DescriptionpHR Salt Bridge, Quantity: 1
TypeSalt Bridge
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
SH36A9E115Full specifications
EachpHR Reference Fill Solution Bridge, without pre-amplifier; 15 ft. cableRequest A Quote--
DescriptionpHR Reference Fill Solution Bridge, without pre-amplifier; 15 ft. cable
TypeFill Solution Bridge
Includeswithout pre-amplifier; 15 ft. cable
Length (English) Cable15 ft.
Length (Metric) Cable4.57 m
Max. Flow Rate10 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
SH36A9E210Full specifications
EachpHR Reference Fill Solution Bridge, with pre-amplifier; 10 ft. cable
Price: 938.00
Your price:
-
ContainsPre-amplifier
DescriptionpHR Reference Fill Solution Bridge, with pre-amplifier; 10 ft. cable
TypeFill Solution Bridge with Pre-amplifier
Includeswith pre-amplifier; 10 ft. cable
Length (English) Cable10 ft.
Length (Metric) Cable4.57 m
Max. Flow Rate3.05 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
For Use With (Equipment)pHR process ROSS electrode
Unit SizeEach
SH36A9E220Full specifications
EachpHR Reference Fill Solution Bridge, with pre-amplifier; 20 ft. cable
Price: 1,050.00
Your price:
-
ContainsPre-amplifier
DescriptionpHR Reference Fill Solution Bridge, with pre-amplifier; 20 ft. cable
TypeFill Solution Bridge with Pre-amplifier
Includeswith pre-amplifier; 20 ft. cable
Length (English) Cable20 ft.
Length (Metric) Cable6.1 m
Max. Flow Rate3.05 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
For Use With (Equipment)pHR process ROSS electrode
Unit SizeEach
SH36A9E230Full specifications
EachpHR Reference Fill Solution Bridge, with pre-amplifier; 30 ft. cable
Price: 1,130.00
Your price:
-
ContainsPre-amplifier
DescriptionpHR Reference Fill Solution Bridge, with pre-amplifier; 30 ft. cable
TypeFill Solution Bridge with Pre-amplifier
Includeswith pre-amplifier; 30 ft. cable
Length (English) Cable30 ft.
Length (Metric) Cable6.1 m
Max. Flow Rate9.1 ft./sec.
Max. Transmission Distance3000 ft. (914m)
Offset0±25mV
pH Range0 to 14
pH Measurement Response30 seconds for 95% of change for a ±3 pH change
pH Measurement Repeatability±0.075
Pressure Range0 to 100psig
Slope92 to 102%
Temperature (Metric) Range0°C to 95°C
Temperature Repeatability±0.5°C
Temperature Response<3 minutes for 90% change for a 10°C temperature change
Certifications/ComplianceCertificate of Analysis (COA), Certificate of Conformance (COC)
Unit SizeEach
Showing 7 of 7

The ROSS™ reference system provides a drift-free measurement system with accurate results. 

Features:

  • Room for 1 in. NPT mounting
  • Replaceable salt bridge that extends sensor life
  • PT1000 temperature element
  • Customizable cable lengths of 10′ to 30′ (kits are available for customization)

Benefits:

  • Accurate, reproducible results
  • Double junction design to prevent contamination
  • Unparalleled pH response to extreme temperature changes

Recommended for:

  • Wastewater Treatment
  • Pharmaceutical
  • Process Water
  • Industrial Water
  • Drinking Water
  • Power Effluent
  • Food Processing
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text