Use the Orion Star T910 pH titrator for dedicated acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN). Titration techniques include equivalence point titrations and preset pH endpoint titrations for versatile sample analysis. Pair the titrator option with any of our premium ROSS pH electrodes or select one of our preconfigured titrator and electrode kits for a bundled discount.
Catalog Number
START9101
Unit Size
Each
Description
Orion Star T910 pH titrator standard ROSS kit
Includes
8102BNUWP ROSS Ultra pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Price (USD)
Price: 3,761.00
Your Price:
Availability
***
Full specifications
Quantity
Accuracy (mV)
±0.2 mV
Accuracy (pH)
±0.002pH
Accuracy (Temperature)
±0.2 °C
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
pH and temperature
Calibration Points (pH)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T910 pH titrator standard ROSS kit
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Type
Acid/base titrator
Equivalence Points
1 to 2
For Use With (Application)
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Includes
8102BNUWP ROSS Ultra pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T910
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe
Range (mV)
-2000.0 to +2000.0 mV
Range (pH)
-2 to 20
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (mV)
0.1 mV
Resolution (pH)
0.001, 0.01, 0.1 (user selectable)
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Price (USD)
Price: 3,449.00
Your Price:
Availability
***
Full specifications
Quantity
Accuracy (mV)
±0.2 mV
Accuracy (pH)
±0.002pH
Accuracy (Temperature)
±0.2 °C
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
pH and temperature
Calibration Points (pH)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T910 pH titrator without electrode
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Type
Acid/base titrator
Equivalence Points
1 to 2
For Use With (Application)
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Includes
20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T910
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe
Range (mV)
-2000.0 to +2000.0 mV
Range (pH)
-2 to 20
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (mV)
0.1 mV
Resolution (pH)
0.001, 0.01, 0.1 (user selectable)
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
8172BNWP ROSS Sure-Flow pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Price (USD)
Price: 3,795.00
Your Price:
Availability
***
Full specifications
Quantity
Accuracy (mV)
±0.2 mV
Accuracy (pH)
±0.002pH
Accuracy (Temperature)
±0.2 °C
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
pH and temperature
Calibration Points (pH)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T910 pH titrator ROSS Sure-Flow kit
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Type
Acid/base titrator
Equivalence Points
1 to 2
For Use With (Application)
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Includes
8172BNWP ROSS Sure-Flow pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T910
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe
Range (mV)
-2000.0 to +2000.0 mV
Range (pH)
-2 to 20
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (mV)
0.1 mV
Resolution (pH)
0.001, 0.01, 0.1 (user selectable)
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
Titration Process Control
Routine, quick, careful or user defined
Titration Setup Wizard
Yes, using Start a New Titration workflow
Titration Technique
Equivalence point or preset endpoint
Titration Types
Direct or back titration
Updateable Firmware
Yes, using USB flash drive
Warranty
1 year replacement warranty
Dimensions (L x W x H)
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm
Electrical Requirements
100-240V, 50/60 Hz
Unit Size
Each
Showing 3 of 3
Catalog Number
Specifications
Unit Size
Description
Includes
Price (USD)
Availability
Quantity
START9101
Full specifications
Each
Orion Star T910 pH titrator standard ROSS kit
8102BNUWP ROSS Ultra pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Price: 3,761.00
Your Price:
***
Accuracy (mV)
±0.2 mV
Accuracy (pH)
±0.002pH
Accuracy (Temperature)
±0.2 °C
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
pH and temperature
Calibration Points (pH)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T910 pH titrator standard ROSS kit
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Type
Acid/base titrator
Equivalence Points
1 to 2
For Use With (Application)
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Includes
8102BNUWP ROSS Ultra pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T910
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe
Range (mV)
-2000.0 to +2000.0 mV
Range (pH)
-2 to 20
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (mV)
0.1 mV
Resolution (pH)
0.001, 0.01, 0.1 (user selectable)
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Price: 3,449.00
Your Price:
***
Accuracy (mV)
±0.2 mV
Accuracy (pH)
±0.002pH
Accuracy (Temperature)
±0.2 °C
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
pH and temperature
Calibration Points (pH)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T910 pH titrator without electrode
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Type
Acid/base titrator
Equivalence Points
1 to 2
For Use With (Application)
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Includes
20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T910
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe
Range (mV)
-2000.0 to +2000.0 mV
Range (pH)
-2 to 20
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (mV)
0.1 mV
Resolution (pH)
0.001, 0.01, 0.1 (user selectable)
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
8172BNWP ROSS Sure-Flow pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Price: 3,795.00
Your Price:
***
Accuracy (mV)
±0.2 mV
Accuracy (pH)
±0.002pH
Accuracy (Temperature)
±0.2 °C
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
pH and temperature
Calibration Points (pH)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T910 pH titrator ROSS Sure-Flow kit
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Type
Acid/base titrator
Equivalence Points
1 to 2
For Use With (Application)
Acid-base titrations including titratable acidity of juices and wines, acidity of food products, alkalinity of waters, acidity and alkalinity of consumer products, total acid number (TAN) and total base number (TBN)
Includes
8172BNWP ROSS Sure-Flow pH electrode, 927007MD ATC probe, 20 mL burette, stirrer probe, dispenser probe, standard tubing kit, 1 L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T910
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
pH electrode, reference half-cell electrode, ATC temperature probe, stirrer probe
Range (mV)
-2000.0 to +2000.0 mV
Range (pH)
-2 to 20
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (mV)
0.1 mV
Resolution (pH)
0.001, 0.01, 0.1 (user selectable)
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
Titration Process Control
Routine, quick, careful or user defined
Titration Setup Wizard
Yes, using Start a New Titration workflow
Titration Technique
Equivalence point or preset endpoint
Titration Types
Direct or back titration
Updateable Firmware
Yes, using USB flash drive
Warranty
1 year replacement warranty
Dimensions (L x W x H)
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm
Electrical Requirements
100-240V, 50/60 Hz
Unit Size
Each
Showing 3 of 3
Accurate, reproducible results: Automating the titration workflow enables analysis to be run using the same setup parameters and calculations every time
Faster setup time: Setup and save electrode, titrant and titration parameters once using methods
Improved lab throughput: Start the titration and let the instrument run unattended
Reduced cost and downtime: Easily replace titrator parts to minimize maintenance downtime while long lasting electrodes reduce the cost of ownership
Securely document test results: View results live, in the summary table and within the 100 point data log
Applications database: Tested and validated preprogrammed methods can be loaded onto your titrator
Standard ROSS kit with 8102BNUWP ROSS Ultra pH electrode and 927007MD stainless steel ATC temperature probe is ideal for most standard pH titrations and especially preset endpoint titrations that include temperature
ROSS Sure-Flow kit with 8172BNWP ROSS Sure-Flow pH electrode is designed for challenging samples that can clog standard pH electrodes or that require a fast-flowing sleeve-type junction