Thermo Scientific™

TruNarc™ Handheld Narcotics Analyzer

Catalog number: TRUNARC
Thermo Scientific™

TruNarc™ Handheld Narcotics Analyzer

Catalog number: TRUNARC
The global drug problem is increasing, with trafficking of methamphetamines, heroin, and emerging threats like fentanyl, and carfentanil, impacting communities worldwide. Law enforcement officials need to quickly identify suspected narcotics in the field to help keep drugs, and drug dealers, off the streets. Now with the expanded v1.9 library, the Thermo Scientific™ TruNarc™ Handheld Narcotics Analyzer enables officers, customs, border control, and other personnel to scan more than 498 suspected controlled substances in a single, definitive test.
 
Catalog Number
TRUNARC
Unit Size
Each
Libraries
Controlled substances, cutting agents, and precursors including: heroin, synthetic drugs on leaf materials or blotter paper
Language Configurations
English, Arabic, Chinese, Czech, Dutch, French, Japanese, Polish, Russian, Spanish
Data Export Formats
CSV, Excel™ spreadsheet, SPC file, PDF, SCN, SCZ
Price (USD)
Full specifications
DescriptionTruNarc Handheld Narcotics Analyzer
Weight (English)1.25 lb.
Weight (Metric)0.570kg
Height (English)2 in.
Height (Metric)5.1cm
Length (English)6.4 in.
Length (Metric)16.26cm
Width (English)4.1 in.
Width (Metric)10.41cm
LibrariesControlled substances, cutting agents, and precursors including: heroin, synthetic drugs on leaf materials or blotter paper
Data Export FormatsCSV, Excel™ spreadsheet, SPC file, PDF, SCN, SCZ
ConfigurationUnlimited or Pay-Per-Scan
Battery TypeRechargeable internal 3.7V battery pack (10 hrs.); DC wall adapter, 5V DC, 1.5A; optional car charger
Temperature (English) Operating14° to +122°F
Temperature (Metric) Operating-10° to +50°C
Power Consumption1.5A
Voltage3.7V
Item DescriptionTruNarc Handheld Narcotics Analyzer
Language ConfigurationsEnglish, Arabic, Chinese, Czech, Dutch, French, Japanese, Polish, Russian, Spanish
Computer AdministrationTruNarc Admin software connected via microUSB to USB
Dimensions (L x W x H)6.4 x 4.1 x 2 in. (16.26 x 10.41 x 5.1cm)
Product TypeHandheld Raman Spectrometer
IncludesReachback Support: Spectral analysis by staff chemists available
Validation: Third party test results available on request
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeLibrariesLanguage ConfigurationsData Export FormatsPrice (USD)
TRUNARCFull specifications
EachControlled substances, cutting agents, and precursors including: heroin, synthetic drugs on leaf materials or blotter paperEnglish, Arabic, Chinese, Czech, Dutch, French, Japanese, Polish, Russian, SpanishCSV, Excel™ spreadsheet, SPC file, PDF, SCN, SCZRequest A Quote
DescriptionTruNarc Handheld Narcotics Analyzer
Weight (English)1.25 lb.
Weight (Metric)0.570kg
Height (English)2 in.
Height (Metric)5.1cm
Length (English)6.4 in.
Length (Metric)16.26cm
Width (English)4.1 in.
Width (Metric)10.41cm
LibrariesControlled substances, cutting agents, and precursors including: heroin, synthetic drugs on leaf materials or blotter paper
Data Export FormatsCSV, Excel™ spreadsheet, SPC file, PDF, SCN, SCZ
ConfigurationUnlimited or Pay-Per-Scan
Battery TypeRechargeable internal 3.7V battery pack (10 hrs.); DC wall adapter, 5V DC, 1.5A; optional car charger
Temperature (English) Operating14° to +122°F
Temperature (Metric) Operating-10° to +50°C
Power Consumption1.5A
Voltage3.7V
Item DescriptionTruNarc Handheld Narcotics Analyzer
Language ConfigurationsEnglish, Arabic, Chinese, Czech, Dutch, French, Japanese, Polish, Russian, Spanish
Computer AdministrationTruNarc Admin software connected via microUSB to USB
Dimensions (L x W x H)6.4 x 4.1 x 2 in. (16.26 x 10.41 x 5.1cm)
Product TypeHandheld Raman Spectrometer
IncludesReachback Support: Spectral analysis by staff chemists available
Validation: Third party test results available on request
Unit SizeEach
Showing 1 of 1

With the TruNarc Handheld Narcotics Analyzer, the accuracy and reliability of a narcotics and drug test lab are available anywhere you go. With this handheld drug detector, narcotics, stimulants, depressants, hallucinogens and analgesics are easily identified using lab-proven Raman spectroscopy.

Single Test, Multiple Narcotics

Identifies more than 300 of the highest priority illicit and abused  narcotics in a single drug test, saving time and money.

Easy to Use

A single drug test for multiple controlled substances provides clear, definitive results for presumptive identification with no user interpretation.

Broad Analysis Capability

Analyze key drugs of abuse as well as common cutting agents, precursors and emerging threats such as fentanyl, numerous fentanyl compounds including carfentanil, common street fentanyl analogs, pharmaceutical variants (Alfentanil and Sufentanil), as well as 2 fentanyl precursors, NPP and ANPP. 

Non-destructive, Non-contact Sampling

Scan directly through plastic or glass for most drug test samples to minimize contamination, reduce exposure and preserve evidence.

Automated Data Storage and Report Generation

TruNarc Admin captures all scan and self check results to help support prosecution.

Reachback Support

Spectral analysis by staff chemists available.

 

Figures

Frequently asked questions (FAQs)