Thermo Scientific™

Savant™ Universal SpeedVac™ Vacuum System

Catalog number: UVS400SPD-230
Thermo Scientific™

Savant™ Universal SpeedVac™ Vacuum System

Catalog number: UVS400SPD-230

Safely handle and recover solvents with the Thermo Scientific™ Savant™ Universal SpeedVac™ Vacuum System, equipped with an easy to use, wide-mouth glass condensation flask. This single integrated unit combines an oil-free vacuum source and refrigerated vapor trap, and can be connected to any of the concentrators to provide a complete SpeedVac system.

 
Catalog Number
UVS400SPD-230
Unit Size
Each
For Use With (Equipment)
SPD121P, SPD131DDA and SC250EXP
Voltage
230 V
Price (USD)
Full specifications
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400SPD; For use with SPD121P, SPD131DDA and SC250EXP; -55°C; 230V/50 Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
For Use With (Equipment)
SPD111V and SC210A
Voltage
115 V
Price (USD)
Full specifications
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400; For use with SPD111V and SC210A; -55°C; 115V/60Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD111V and SC210A
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
For Use With (Equipment)
SPD111V and SC210A
Voltage
230 V
Price (USD)
Full specifications
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400; For use with SPD111V and SC210A; -55°C; 230V/50 Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD111V and SC210A
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
For Use With (Equipment)
SPD121P, SPD131DDA and SC250EXP
Voltage
115 V
Price (USD)
Full specifications
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400SPD; For use with SPD121P, SPD131DDA and SC250EXP; -55°C; 115V/60Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
For Use With (Equipment)
SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP
Voltage
115 V
Price (USD)
Full specifications
DescriptionUniversal vacuum system for drug discovery; UVS800DDA; For use with SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP; -50°C; 115V/60Hz
TypeVacuum System
For Use With (Application)Drug Discovery
For Use With (Equipment)SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-50°C
Volume (Metric)4 L
Shipping Weight (English)126 lb.
Shipping Weight (Metric)57 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
For Use With (Equipment)
SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP
Voltage
230 V
Price (USD)
Full specifications
DescriptionUniversal vacuum system for drug discovery; UVS800DDA; For use with SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP; -50°C; 230V/50Hz
TypeVacuum System
For Use With (Application)Drug Discovery
For Use With (Equipment)SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-50°C
Volume (Metric)4 L
Shipping Weight (English)126 lb.
Shipping Weight (Metric)57 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Showing 6 of 6
Catalog NumberSpecificationsUnit SizeFor Use With (Equipment)VoltagePrice (USD)
UVS400SPD-230Full specifications
EachSPD121P, SPD131DDA and SC250EXP230 VRequest A Quote
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400SPD; For use with SPD121P, SPD131DDA and SC250EXP; -55°C; 230V/50 Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
UVS400-115Full specifications
EachSPD111V and SC210A115 VRequest A Quote
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400; For use with SPD111V and SC210A; -55°C; 115V/60Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD111V and SC210A
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
UVS400A-230Full specifications
EachSPD111V and SC210A230 VRequest A Quote
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400; For use with SPD111V and SC210A; -55°C; 230V/50 Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD111V and SC210A
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
UVS400SPD-115Full specifications
EachSPD121P, SPD131DDA and SC250EXP115 VRequest A Quote
DescriptionUniversal vacuum system with refrigerated vapor trap; UVS400SPD; For use with SPD121P, SPD131DDA and SC250EXP; -55°C; 115V/60Hz
TypeVacuum System with Refrigerated Vapor Trap
For Use With (Equipment)SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-55°C
Volume (Metric)4 L
Shipping Weight (English)113 lb.
Shipping Weight (Metric)51 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
UVS800DDA-115Full specifications
EachSPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP115 VRequest A Quote
DescriptionUniversal vacuum system for drug discovery; UVS800DDA; For use with SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP; -50°C; 115V/60Hz
TypeVacuum System
For Use With (Application)Drug Discovery
For Use With (Equipment)SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-50°C
Volume (Metric)4 L
Shipping Weight (English)126 lb.
Shipping Weight (Metric)57 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
UVS800DDA-230Full specifications
EachSPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP230 VRequest A Quote
DescriptionUniversal vacuum system for drug discovery; UVS800DDA; For use with SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP; -50°C; 230V/50Hz
TypeVacuum System
For Use With (Application)Drug Discovery
For Use With (Equipment)SPD111V, SC210A, SPD121P, SPD131DDA and SC250EXP
Shipping Height (English)18 in.
Shipping Height (Metric)450 mm
Shipping Length (English)24 in.
Shipping Length (Metric)600 mm
Shipping Width (English)14 in.
Shipping Width (Metric)250 mm
Temperature (Metric) Range-50°C
Volume (Metric)4 L
Shipping Weight (English)126 lb.
Shipping Weight (Metric)57 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Showing 6 of 6

Savant UVS400:

  • Low maintenance, oil-free and corrosion resistant system
  • Wide mouth glass condensation flask with self-sealing cover
  • Small footprint
  • Single stage refrigeration system
  • Efficient operation with all SpeedVac concentrators, gel dryers and other vacuum-dependent equipment
  • Optional post trap (model no. ANT100) may be added to neutralize ammonia or acid
  • Chemical trap (model no. DTK120R) may be added to absorb volatile radioactivity and residual vapor
  • Max. vacuum <10 torr (13.3mbar)
  • Oil-free ETFE diaphragm pump
  • 36 liters/minute displacement on 60Hz; 30 liters/minute on 50Hz models

Savant US800DDA:

All the standard features as well as:

  • 3-stage high efficiency oil free pump
  • Max. Vacuum <0.6 torr
  • 36 liters/minute on 60Hz; 20 liters/minute on 50Hz models
  • PTFE tubing and vapor path
  • Post trap ANT100 included
  • Order ANS121/4 ammonia neutralizing solution separately
  • VaporNet™ solvent recovery enhancement

Requires:

Thermo Scientific™ CryoCool™ heat transfer fluid (model no. SCC1) must be ordered for use with all refrigerated cold traps, and the universal vacuum source. Please order separately.