5626, 5628 Secondary Standard PRTs
Fluke™

5626, 5628 Secondary Standard PRTs

Fluke Calibration's high-temp secondary standards fill the gap between affordable, but temperature-limited secondary PRTs (platinum resistance thermometers) and more expensive, highly accurate SPRTs (standard platinum resistance thermometers).
Have Questions?
Change viewbuttonViewtableView
Catalog NumberConnector TypesLength (English) ProbeType
5628-15-D5-pin DIN15 in.25.5 Ohm Resistance
5628-12-JBanana Plug12 in.25.5 Ohm Resistance
5628-12-LMini Spade Lugs12 in.25.5 Ohm Resistance
5628-12-MMini Banana Plug12 in.25.5 Ohm Resistance
5628-12-PINFO-CON (1523/1524 models)12 in.25.5 Ohm Resistance
Catalog number 5628-15-D
Price (USD)
-
Connector Types:
5-pin DIN
Length (English) Probe:
15 in.
Type:
25.5 Ohm Resistance

If you're using block calibrators, furnaces, or temperature points above normal PRT (platinum resistance thermometer) temperatures (420 °C), then these two PRTs are for you. The Fluke 5626 is nominally 100 Ω and the 5628 (formerly Hart Scientific) is nominally 25.5 Ω. Both instruments have a temperature range of –200 °C to 661 °C. They make great working or check standards for calibration work up to the aluminum point.

Fluke 5626 Secondary Standard PRTs, 100 OHM 1/4 Diameter X 20 inch

High-temperature secondary standards

• Range to 661°C
• Meets all ITS-90 requirements for resistance ratios
• Rtp drift < 20 mK after 500 hours at 661°C
• Calibrated accuracy of ± 0.006 °C at 0 °C

Fluke Calibration's high-temp secondary standards fill the gap between affordable, but temperature-limited secondary PRTs (platinum resistance thermometers) and more expensive, highly accurate SPRTs (standard platinum resistance thermometers).

Description
If you're using block calibrators, furnaces, or temperature points above normal PRT (platinum resistance thermometer) temperatures (420 °C), then these two PRTs are for you. The Fluke 5626 is nominally 100 Ω and the 5628 (formerly Hart Scientific) is nominally 25.5 Ω. Both instruments have a temperature range of –200 °C to 661 °C. They make great working or check standards for calibration work up to the aluminum point.

Using a regular PRT at temperatures above 500 °C exposes the platinum to contamination. If the PRT is used as a reference or calibration standard, contamination is a major problem. SPRTs (standard platinum resistance thermometers), which are more expensive and delicate, can handle the higher temperatures, but with greater risk to the instrument due to shock, contamination, or mishandling. The 5626 and 5628 are designed to reduce the contamination risk through the use of internal protection while not impairing performance.

In addition to the right measurement performance and durability, a PRT for secondary applications should be priced affordably. Fluke Calibration’s new PRTs are inexpensive and come with an accredited calibration. The calibration comes complete with ITS-90 constants and a resistance-versus-temperature table.

Check the temperature range, check the stability, check the price! Who else gives you this much quality, performance, and value for your money? No one!

Specifications
Temperature Range: –200 °C to 661 °C
Handle Temp: 0 °C to 80 °C
RTPW: 100 Ω (± 1 Ω)
Resistance Ratio W(Ga) W(302.9146K) ≥ 1.11807 α ≥ 0.003925
Calibrated Accuracy† (k=2):
± 0.006 °C at –200 °C
± 0.006 °C at 0 °C
± 0.015 °C at 420 °C
± 0.022 °C at 661 °C
Stability: ± 0.003 °C
Long-Term Drift (k=2): < 0.006 °C/100 hours at 661 °C
Immersion: At least 12.7 cm (5 in) recommended
Sheath: Inconel™ 600
Lead Wires: 4-wire Super-Flex PVC, 22 AGW
Size: 6.35 mm dia. x 305 mm, 381 mm, or 508 mm (0.25 x 12, 15, or 20 in) standard, custom lengths available
Calibration: Accredited calibrations from Fluke Calibration
†Includes calibration and 100 hr drift
Warranty: 1 year (limited)

Model: 5626-20-S (spade lugs)
High-temp PRT, 100 Ω, 508 mm (20 in)
Includes case (17025 accredited calibration included. Traceable to NIST standards.)

Specifications
Length (English) Probe15 in.
Temperature (Metric) Range-200°C to +661°C
Connector Types5-pin DIN
Temperature (Metric) Operating0°C to 80°C (Handle)
Type25.5 Ohm Resistance
Unit SizeEach