| STARA2120 | Full specifications | Each | Orion Star A212 conductivity/TDS/salinity/resistivity benchtop meter with stand | Star A212 conductivity meter, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate | Contact Us › |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS | Description | Orion Star A212 conductivity/TDS/salinity/resistivity benchtop meter with stand | Outputs | USB, RS232 | Includes | Star A212 conductivity meter, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate | Measurement Modes | Conductivity, TDS, Salinity, Resistivity with Temperature | Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature | Cell Constant | 0.001 to 199.9cm-1 | Calibration | Conductivity with calibration editing option and temperature | Calibration Points (Conductivity) | 5 | Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm | Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits | Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit | Temperature (Metric) Reference | 5, 10, 15, 20, 25°C | Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt | Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging | Accuracy (Salinity) | 0.5% of reading ±1 digit | Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) | Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits | Accuracy (TDS) | 0.5% of reading ±1 digit | TDS Factor Range | Linear (0.02 to 9.99) | Temperature Range (Metric) | -5°C to +105°C | Resolution (Temperature) | 0.1°C (0.1°F) | Accuracy (Temperature) | ±0.1°C | Range (Resistivity) | 2 ohm to 100.0 megohm | Temperature Selection | Manual or automatic with ATC temperature probe | Temperature Probe Calibration | 1 point temperature offset calibration | Display Type | Graphic LCD with Backlight | Backlight Option | Yes, selectable | Memory | Non-volatile memory preserves data log, calibration log and meter settings | Data Points | 2000 with date and time stamp | Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m | Data Management Details | Transfer single, range or all data points to printer or computer | Alarm Output | High/low limit alarm, calibration due alarm | Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) | Certifications/Compliance | CE, TUV 3-1, FCC Class A | IP Rating | IP54 | AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) | Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) | Weight (Metric) | 0.9 kg | Weight (English) | 2 lb. | Warranty | 3 Year Meter | Probe Type | Conductivity sensor, stirrer probe (purchase separately) | Relative Humidity Range | 5 to 85%, non-condensing | Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter | Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging | Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) | Methods | 10 per channel with password protection | Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting | Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys | Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update | Temperature (English) Operating | 41°F to 113°F (ambient) | Temperature (Metric) Operating | 5°C to 45°C (ambient) | Channels | 1 | Accuracy (Resistivity) | 0.5% of reading ±1 digit | Battery Type | 4 x AA (sold separately) | Battery Life | 800 hr. | Unit Size | Each |
|
| STARA2125 | Full specifications | Each | Orion Star A212 conductivity/TDS/salinity/resistivity benchtop meter kit with DuraProbe 4-cell conductivity sensor, solutions and stand | Star A212 conductivity meter, DuraProbe 4-cell conductivity sensor, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate | Contact Us › |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS | Description | Orion Star A212 conductivity/TDS/salinity/resistivity benchtop meter kit with DuraProbe 4-cell conductivity sensor, solutions and stand | Outputs | USB, RS232 | Includes | Star A212 conductivity meter, DuraProbe 4-cell conductivity sensor, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate | Measurement Modes | Conductivity, TDS, Salinity, Resistivity with Temperature | Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature | Cell Constant | 0.001 to 199.9cm-1 | Calibration | Conductivity with calibration editing option and temperature | Calibration Points (Conductivity) | 5 | Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm | Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits | Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit | Temperature (Metric) Reference | 5, 10, 15, 20, 25°C | Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt | Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging | Accuracy (Salinity) | 0.5% of reading ±1 digit | Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) | Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits | Accuracy (TDS) | 0.5% of reading ±1 digit | TDS Factor Range | Linear (0.02 to 9.99) | Temperature Range (Metric) | -5°C to +105°C | Resolution (Temperature) | 0.1°C (0.1°F) | Accuracy (Temperature) | ±0.1°C | Range (Resistivity) | 2 ohm to 100.0 megohm | Temperature Selection | Manual or automatic with ATC temperature probe | Temperature Probe Calibration | 1 point temperature offset calibration | Display Type | Graphic LCD with Backlight | Backlight Option | Yes, selectable | Memory | Non-volatile memory preserves data log, calibration log and meter settings | Data Points | 2000 with date and time stamp | Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m | Data Management Details | Transfer single, range or all data points to printer or computer | Alarm Output | High/low limit alarm, calibration due alarm | Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) | Certifications/Compliance | CE, TUV 3-1, FCC Class A | IP Rating | IP54 | AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) | Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) | Weight (Metric) | 0.9 kg | Weight (English) | 2 lb. | Warranty | 3 Year Meter | Probe Type | Conductivity sensor, stirrer probe (includes 013005MD Orion DuraProbe 4-cell conductivity sensor) | Relative Humidity Range | 5 to 85%, non-condensing | Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter | Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging | Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) | Methods | 10 per channel with password protection | Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting | Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys | Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update | Temperature (English) Operating | 41°F to 113°F (ambient) | Temperature (Metric) Operating | 5°C to 45°C (ambient) | Channels | 1 | Accuracy (Resistivity) | 0.5% of reading ±1 digit | Battery Type | 4 x AA (sold separately) | Battery Life | 800 hr. | Unit Size | Each |
|
| STARA2126 | Full specifications | Each | Orion Star A212 conductivity/TDS/salinity/resistivity benchtop meter kit with ultra pure water conductivity sensor, solutions and stand | Star A212 conductivity meter, ultra pure water conductivity sensor, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate | Contact Us › |
Accuracy (Conductivity) | 0.5% of reading ±1 digit > 3 μS; 0.5% of reading ±0.01 μS ≤ 3 μS | Description | Orion Star A212 conductivity/TDS/salinity/resistivity benchtop meter kit with ultra pure water conductivity sensor, solutions and stand | Outputs | USB, RS232 | Includes | Star A212 conductivity meter, ultra pure water conductivity sensor, electrode stand, universal power adapter, literature CD, printed quick start guide, computer interface cable and meter test certificate | Measurement Modes | Conductivity, TDS, Salinity, Resistivity with Temperature | Compatible Probes | 2-cell or 4-cell conductivity sensors with built-in temperature | Cell Constant | 0.001 to 199.9cm-1 | Calibration | Conductivity with calibration editing option and temperature | Calibration Points (Conductivity) | 5 | Range (Conductivity) | 0.001 μS/cm to 3000 mS/cm | Resolution (Conductivity) | 0.001 μS minimum, auto ranging up to 4 significant digits | Temperature Compensation | Linear, nLFn (non-linear ultra pure water), nLFu (non-linear ultra pure degassed water), EP (off wit | Temperature (Metric) Reference | 5, 10, 15, 20, 25°C | Range (Salinity) | 0.06 to 80.00 psu, 0.05 to 42.00 ppt | Resolution (Salinity) | 0.01 psu or 0.01 ppt minimum, auto ranging | Accuracy (Salinity) | 0.5% of reading ±1 digit | Salinity Measurement Modes | Practical salinity (psu) or natural sea water (ppt) | Resolution (TDS) | 0.001 ppm minimum, auto ranging up to 4 significant digits | Accuracy (TDS) | 0.5% of reading ±1 digit | TDS Factor Range | Linear (0.02 to 9.99) | Temperature Range (Metric) | -5°C to +105°C | Resolution (Temperature) | 0.1°C (0.1°F) | Accuracy (Temperature) | ±0.1°C | Range (Resistivity) | 2 ohm to 100.0 megohm | Temperature Selection | Manual or automatic with ATC temperature probe | Temperature Probe Calibration | 1 point temperature offset calibration | Display Type | Graphic LCD with Backlight | Backlight Option | Yes, selectable | Memory | Non-volatile memory preserves data log, calibration log and meter settings | Data Points | 2000 with date and time stamp | Log Function Type | Automatic data logging with Auto-Read and Timed measure modes; manual data logging with Continuous m | Data Management Details | Transfer single, range or all data points to printer or computer | Alarm Output | High/low limit alarm, calibration due alarm | Inputs | 8 pin MiniDIN (conductivity sensor with built-in temperature), stirrer input (stirrer probe) | Certifications/Compliance | CE, TUV 3-1, FCC Class A | IP Rating | IP54 | AC Adapter | Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003) | Dimensions (L x W x H) | 24 x 18 x 11 cm (9.5 x 7.1 x 4.3 in.) | Weight (Metric) | 0.9 kg | Weight (English) | 2 lb. | Warranty | 3 Year Meter | Probe Type | Conductivity sensor, stirrer probe (includes 013016MD Orion ultra pure water 2-cell conductivity sensor) | Relative Humidity Range | 5 to 85%, non-condensing | Model | Orion Star A212 Conductivity/TDS/Salinity/Resistivity/Temperature Benchtop Meter | Resolution (Resistivity) | 1 ohm or 0.1 megohm, auto ranging | Power Supply | Universal AC adapter (included) or 4 AA batteries (sold separately) | Methods | 10 per channel with password protection | Stability | Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting | Keypad | Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys | Languages | English, Spanish, French, Italian, German and Chinese; Portuguese and Korean available with software update | Temperature (English) Operating | 41°F to 113°F (ambient) | Temperature (Metric) Operating | 5°C to 45°C (ambient) | Channels | 1 | Accuracy (Resistivity) | 0.5% of reading ±1 digit | Battery Type | 4 x AA (sold separately) | Battery Life | 800 hr. | Unit Size | Each |
|