Kit de CD3 humano Dynabeads™ FlowComp™
Kit de CD3 humano Dynabeads™ FlowComp™
Invitrogen™

Kit de CD3 humano Dynabeads™ FlowComp™

Dynabeads™ FlowComp™ Human CD3 contiene microesferas magnéticas que proporcionan una herramienta robusta y versátil para aislar positivamente las células TMás información
Have Questions?
Número de catálogoCantidad
11365D1 Kit
Número de catálogo 11365D
Precio (USD)
2.381,40
Each
Añadir al carro de la compra
Cantidad:
1 Kit
Precio (USD)
2.381,40
Each
Añadir al carro de la compra
Dynabeads™ FlowComp™ Human CD3 contiene microesferas magnéticas que proporcionan una herramienta robusta y versátil para aislar positivamente las células T CD3+ puras de sangre completa, médula ósea, capa leucocítica, células mononucleares (MNC) o digestiones de tejidos. Las células se pueden liberar de las partículas mediante el tampón de liberación FlowComp™.
• Aislamiento rápido de células T CD3+ de cualquier muestra: no se requieren columnas
• Células T CD3+ puras y sin partículas para cualquier aplicación posterior

Excelente rendimiento, pureza y viabilidad de células recuperadas
El anticuerpo CD3 humano Dynabeads™ FlowComp™ contiene microesferas uniformes superparamagnéticas (de 2,8 µm de diámetro) que permiten el aislamiento sencillo de las células CD3+ humanas directamente de cualquier muestra a través de un proceso de tres pasos. En primer lugar, el anticuerpo CD3 humano FlowComp™ se mezcla con la muestra en un tubo donde se une a las células diana durante una incubación corta. Luego, las células CD3+ T que han ligado los anticuerpos específicos son capturadas por los Dynabeads™ FlowComp™ y separadas de las células no unidas usando un imán. Por último, las células diana se liberan de las partículas mediante la adición del tampón de liberación FlowComp™. Este método de aislamiento rápido y suave no requiere el uso de columnas y ayuda a garantizar la alta pureza, recuperación y viabilidad de las células CD3+. Las células se pueden utilizar en cualquier aplicación posterior.

Seleccione la mejor opción de nuestra gama de productos de aislamiento de células T humanas.

Para uso exclusivo en investigación. No se ha diseñado para uso diagnóstico o terapéutico en animales o humanos.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Tipo de célulaCélulas T (CD3)
Tipo de producto finalCélulas
FormatoGráfico de
Tecnología de aislamientoAislamiento positivo
N.° de celdas80 ml de sangre completa o 2 x 10^9 de PBMC
Línea de productosDYNAL, Dynabeads, FlowComp
Grado de pureza o calidadCalidad para investigación, 99 %
Cantidad1 Kit
Tipo de muestraMNC, sangre
Condiciones de envíoTemperatura ambiente
Especies dianaHumano
Diámetro (métrico)2,8 μm
Tipo de productoKit de CD3 humano
Unit SizeEach
Contenido y almacenamiento
El kit contiene 1 ml de mezcla de anticuerpos, 3 ml de FlowComp™ Dynabeads™ y 40 ml de tampón de liberación FlowComp™.
Almacenar a: 2-8° C

Preguntas frecuentes

My Dynabeads magnetic beads are not pelleting well with the magnet. Do you have any suggestions for me?

Please review the following possibilities for why your Dynabeads magnetic beads are not pelleting:

- The solution is too viscous.
- The beads have formed aggregates because of protein-protein interaction.

Try these suggestions: - Increase separation time (leave tub on magnet for 2-5 minutes)
- Add DNase I to the lysate (~0.01 mg/mL)
- Increase the Tween 20 concentration to ~0.05% of the binding and/or washing buffer.
- Add up to 20 mM beta-merecaptoethanol to the binding and/or wash buffers.

Find additional tips, troubleshooting help, and resources within our Dynabeads Nucleic Acid Purification Support Center.

I have a long double-stranded DNA fragment I would like to isolate. What product do you recommend?

For biotin-labeled DNA that is less than 1 kb, we recommend you use Dynabeads M270 Streptavidin (Cat. No. 65305) and MyOne C1 magnetic beads (Cat. No. 65001). We recommend our Dynabeads KilobaseBINDER Kit (Cat. No. 60101), which is designed to immobilize long (>1 kb) double-stranded DNA molecules. The KilobaseBINDER reagent consists of M-280 Streptavidin-coupled Dynabeads magnetic beads along with a patented immobilization activator in the binding solution to bind to long, biotinylated DNA molecules for isolation. Please see the following link (https://www.thermofisher.com/us/en/home/life-science/dna-rna-purification-analysis/napamisc/capture-of-biotinylated-targets/immobilisation-of-long-biotinylated-dna-fragments.html) for more information in regards to long biotinylated DNA fragment isolation.

Find additional tips, troubleshooting help, and resources within our Dynabeads Nucleic Acid Purification Support Center.

Can I use Dynabeads magnetic beads to isolate single-stranded DNA templates?

Yes, Dynabeads magnetic beads can be used to isolate single-stranded DNA. Streptavidin Dynabeads magnetic beads can be used to target biotinylated DNA fragments, followed by denaturation of the double-stranded DNA and removal of the non-biotinylated strand. The streptavidin-coupled Dynabeads magnetic beads will not inhibit any enzymatic activity. This enables further handling and manipulation of the bead-bound DNA directly on the solid phase. Please see the following link (https://www.thermofisher.com/us/en/home/life-science/dna-rna-purification-analysis/napamisc/capture-of-biotinylated-targets/preparing-single-stranded-dna-templates.html) for more information in regards to single-stranded DNA capture.

Find additional tips, troubleshooting help, and resources within our Dynabeads Nucleic Acid Purification Support Center.

What is the magnetic susceptibility for Dynabeads magnetic beads?

Magnetic susceptibility is a measure of how quickly the beads will migrate to the magnet. This will depend on the iron content and the character of the iron oxide. The magnetic susceptibility given for the Dynabeads magnetic beads is the mass susceptibility, given either as cgs units/g or m^3/kg (the latter being an SI unit). For ferri- and ferromagnetic substances, the magnetic mass susceptibility is dependent upon the magnetic field strength (H), as the magnetization of such substances is not a linear function of H but approaches a saturation value with increasing field. For that reason, the magnetic mass susceptibility of the Dynabeads magnetic beads is determined by a standardized procedure under fixed conditions. The magnetic mass susceptibility given in our catalog is thus the SI unit. Conversion from Gaussian (cgs, emu) units into SI units for magnetic mass susceptibility is achieved by multiplying the Gaussian factor (emu/g or cgs/g) by 4 pi x 10^-3. The resulting unit is also called the rationalized magnetic mass susceptibility, which should be distinguished from the (SI) dimensionless magnetic susceptibility unit. In general, magnetic mass susceptibility is a measure of the force (Fz) influencing an object positioned in a nonhomogenous magnetic field. The magnetic mass susceptibility of the Dynabeads magnetic beads is measured by weighing a sample, and then subjecting the sample to a magnetic field of known strength. The weight (F1) is then measured, and compared to the weight of the sample when the magnetic field is turned off (F0). The susceptibility is then calculated as K x 10^-3 = [(F1-F0) x m x 0.335 x 10^6], where K is the mass susceptibility of the sample of mass m. The susceptibility is then converted to SI units.

Find additional tips, troubleshooting help, and resources within our Dynabeads Nucleic Acid Purification Support Center.

How can I determine coupling efficiency of Dynabeads magnetic beads?

There are different methods to check binding of ligands to the beads, including optical density (OD) measurement, fluorescent labeling, and radioactive labeling.

For OD measurement, you would measure the OD of the ligand before immobilization to the beads and compare it with the ligand concentration that is left in the supernatant after coating. This gives a crude measurement of how much protein has bound to the beads.

Protocol:

1.Set spectrophotometer to the right wavelength. As a blank, use the Coupling Buffer.
2.Measure the absorbance of the Pre-Coupling Solution. A further dilution may be necessary to read the absorbance, depending upon the amount of ligand added.
3.Measure the absorbance of the Post-Coupling Solution. A dilution may be necessary to read the absorbance.
4.Calculate the coupling efficiency, expressed as the % protein uptake, as follows. [(Pre-Coupling Solution x D) - (Post-Coupling Solution x D)] x 100/(Pre-Coupling Solution x D) where D = dilution factor.

For fluorescent labeling, we suggest negatively quantifying the amount of ligand bound by measuring ligand remaining in the coupling supernatant (compared to the original sample), rather than directly measuring the ligands on the beads. Add labeled ligand to the beads, and measure how much ligand is left in the supernatant (not bound to the beads). By comparing this with the total amount added in the first place, you can then calculate how much of the ligand that has been bound to the beads. Keep in mind that the Dynabeads magnetic beads are also autofluorescent, which is why direct measuring of fluorescence of the bead-bound ligands is not recommended, but rather this indirect approach. The label could be, for example, FITC/PE. Some researchers perform a direct approach with success (using a flow cytometer).

Radioactive labeling is the most sensitive method of the three, but it is also the most difficult one. It involves radioactively labeling a portion of the ligand. We use radiolabeled I-125 in tracer amounts and mix it with "cold" ligands in a known ratio before coupling. The absolute quantities for the ligand on the beads should be obtained by measuring the beads in a scintillation (gamma) counter and comparing the cpm with a standard.

Protocol:

1.Take out an appropriate amount of beads and wash the beads in 1 mL of binding buffer.
2.Pipette out desired amount of human IgG in a separate tube.
3.Mix the human IgG with I-125-labeled human IgG (30,000 - 100,000 cpm).
4.Dilute the mixture of human IgG and I-125-labeled human IgG to 100 mL in binding buffer.
5.Incubate for 30 minutes at room temperature and measure the cpm in a scintillation counter.
6.Wash the beads (with coating) four times, and measure cpm again.
The % binding is calculated by using the equation : (cpm after washing/cpm before washing)x100%.

Find additional tips, troubleshooting help, and resources within our Dynabeads Nucleic Acid Purification Support Center.