Thermo Scientific™

ImmunoCAP™ Miscellaneous Food Allergens

Número de catálogo: 14506510
Thermo Scientific™

ImmunoCAP™ Miscellaneous Food Allergens

Número de catálogo: 14506510
Quantify specific IgE antibodies with ImmunoCAP™ Miscellaneous Food Allergens, essential tools to aid in the diagnosis of allergic conditions. IgE antibodies appear in human serum and plasma as a result of sensitization to a specific allergen. Measurement of circulating IgE antibodies provides an objective assessment of sensitization to an allergen. In general, low IgE antibody levels indicate a low probability of allergic disease, whereas high antibody levels to an allergen show a higher correlation with an allergic disease.
 
Número de catálogo
14506510
Formato
Each
Nombre común
Coffee
Código
Rf221
Cantidad
10 Tests
Precio (ARS)
Especificaciones completas
Scientific NameCoffea spp.
Estado normativoASR
Code TypeMiscellaneous Food
Nombre comúnCoffee
Cantidad10 Tests
CódigoRf221
Unit SizeEach
Número de catálogo
Formato
Each
Nombre común
Cacao
Código
f93
Cantidad
10 Tests
Precio (ARS)
Especificaciones completas
Scientific NameTheobroma cacao
Estado normativoFDA Cleared
Code TypeMiscellaneous Food
Nombre comúnCacao
Cantidad10 Tests
Códigof93
Unit SizeEach
Número de catálogo
Formato
Each
Nombre común
Honey
Código
Rf247
Cantidad
10 Tests
Precio (ARS)
Especificaciones completas
Estado normativoASR
Code TypeMiscellaneous Food
Nombre comúnHoney
Cantidad10 Tests
CódigoRf247
Unit SizeEach
Número de catálogo
Formato
Each
Nombre común
Mushroom (champignon)
Código
Rf212
Cantidad
10 Tests
Precio (ARS)
Especificaciones completas
Scientific NameAgaricus hortensis
Estado normativoASR
Code TypeMiscellaneous Food
Nombre comúnMushroom (champignon)
Cantidad10 Tests
CódigoRf212
Unit SizeEach
Mostrando 4 de 4
Número de catálogoEspecificacionesFormatoNombre comúnCódigoCantidadPrecio (ARS)
14506510Especificaciones completas
EachCoffeeRf22110 TestsContáctenos ›
Scientific NameCoffea spp.
Estado normativoASR
Code TypeMiscellaneous Food
Nombre comúnCoffee
Cantidad10 Tests
CódigoRf221
Unit SizeEach
14433501Especificaciones completas
EachCacaof9310 TestsContáctenos ›
Scientific NameTheobroma cacao
Estado normativoFDA Cleared
Code TypeMiscellaneous Food
Nombre comúnCacao
Cantidad10 Tests
Códigof93
Unit SizeEach
14507810Especificaciones completas
EachHoneyRf24710 TestsContáctenos ›
Estado normativoASR
Code TypeMiscellaneous Food
Nombre comúnHoney
Cantidad10 Tests
CódigoRf247
Unit SizeEach
14508610Especificaciones completas
EachMushroom (champignon)Rf21210 TestsContáctenos ›
Scientific NameAgaricus hortensis
Estado normativoASR
Code TypeMiscellaneous Food
Nombre comúnMushroom (champignon)
Cantidad10 Tests
CódigoRf212
Unit SizeEach
Mostrando 4 de 4
ImmunoCAP Specific IgE offers the laboratory:
  • Truly quantitative measuring range from 0.1 to 100 kUA/L
  • Intra-assay CV (%) comparable to routine clinical chemistry immunoassays
  • Excellent consistency over time, and between countries, systems, labs and persons
Expected test values
ImmunoCAP Specific IgE detects IgE antibodies in the range 0.1 to 100 kUA /l, where A represents allergen-specific antibodies. The result is reported quantitatively. In clinical practice, 0.35 kUA /l has commonly been used as a cut-off. A large number of studies have been performed to evaluate the clinical performance of ImmunoCAP Specific IgE tests in allergy diagnosis. Clinical performance is expressed as sensitivity, ranging from 84 to 95%, and specificity, ranging from 85 to 94%. Sensitivity and specificity were reported from multi-center studies including several hundred patients tested for a range of different allergens.
  • Specimen collection and preparation
  • Use serum and plasma (EDTA or heparin) samples from venous or capillary blood
  • Collect blood samples using standard procedures
  • Keep specimens at room temperature (RT) for shipping purposes only
  • Store at 2–8°C up to one week, otherwise store at –20°C
  • Avoid repeated freezing and thawing

Note: Blood samples for testing ImmunoCAP drugs and venom should be collected during or close to the event, preferably not later than 6 months after exposure. If the test result is negative and an IgE-mediated reaction is still strongly suspected, it is advisable to draw a new sample and repeat the test at 5 to 6 weeks.

The presence of specific IgE antibodies is useful to identify the allergens that elicit symptoms and signs of allergy in patients with respiratory allergic diseases including asthma, food allergy, and anaphylactic sensitivity.

Knowing IgE antibody levels provides guidance to clinicians to:
  • Identify offending allergens
  • Tailor advice to individual patients
  • Indicate development of tolerance (food allergy, specific immunotherapy)
  • Inform optimized individual medical treatment plans
  • Refer to specialists appropriately
  • Evaluate whether or not specific immunotherapy is an option

Specific IgE testing also aids in the identification of patients at risk of:
  • The allergy march – a progression of skin symptoms to respiratory symptoms
  • Severe symptoms including asthma exacerbations – a progression of mild symptoms to severe symptoms
  • Progression of recurrent symptoms to persistent symptoms

As in all diagnostic testing, a definitive clinical diagnosis should be made by the clinician after evaluation of all clinical and laboratory findings.

Figuras

Documentos y descargas

Certificados

    Preguntas frecuentes

    Citas y referencias

    Search citations by name, author, journal title or abstract text