KingFisher™ Flex 24 Deep Well heating block
KingFisher™ Flex 24 Deep Well heating block
Thermo Scientific™

KingFisher™ Flex 24 Deep Well heating block

El termobloque de 24 pocillos profundos KingFisher™ Flex es compatible con la placa de 24 pocillos profundos KingFisher™ Flex cuandoMás información
Have Questions?
Número de catálogo 24075440
Precio (USD)
-
El termobloque de 24 pocillos profundos KingFisher™ Flex es compatible con la placa de 24 pocillos profundos KingFisher™ Flex cuando se utiliza en el procesador de partículas magnéticas KingFisher™ Flex con un cabezal de 24 pocillos profundos.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
FormatoBloque de calentamiento de 24 pocillos profundos
Capacidad24 muestras
Para utilizar con (equipo)KingFisher™ Flex
Línea de productosKingFisher™
Condiciones de envíoTemperatura ambiente
Unit SizeEach

Preguntas frecuentes

Can the KingFisher Flex heating blocks be purchased separately?

Yes, here are the catalog numbers for standalone heating blocks:

- Cat. No. 24075420: KingFisher Flex 96 KF Heating Block
- Cat. No. 24075430: KingFisher Flex 96 Deep-Well Heating Block
- Cat. No. 24075440: KingFisher Flex 24 Deep-Well Heating Block

Does the KingFisher Flex Magnetic Particle Processor with 24 Deep-Well Head come with a heating block?

Yes, it comes with the KingFisher Flex 24 Deep-Well Heating Block.

I see that the KingFisher 24 Deep Well Head has a processing volume of 5 mL. Does that mean that I can process up to 5 mL of my sample?

No, the processing volume refers to the maximum volume that can be held in the 24 Deep Well plates. This incorporates the volume of binding buffers and beads, so when scaling up reaction volumes, it is important to make sure that the total volume does not exceed 5 mL.

My KingFisher Flex run was stopped due to an error message. Can I start the protocol from where it stopped?

No, once a protocol was stopped, it will restart from the beginning. The extraction procedure can either be finished manually by using a magnetic stand, or a modified version of the original KingFisher Flex script would have to be created that starts off at the point where the run was stopped.

I have a 12-plate protocol but there are only 8 slots on the KingFisher Flex instrument turntable. What should I do with the remaining 4 plates?

Set up the protocol on the BindIt software. After the first 8 plates are done, the instrument will pause and instruct you to switch out the plates.