DS-33 GeneScan™ Installation Standards with GeneScan™ 600 LIZ™ Size Standard v2.0
DS-33 GeneScan™ Installation Standards with GeneScan™ 600 LIZ™ Size Standard v2.0
Applied Biosystems™

DS-33 GeneScan™ Installation Standards with GeneScan™ 600 LIZ™ Size Standard v2.0

El patrón de instalación DS-33 de GeneScan™ consta de productos de PCR agrupados etiquetados con colorantes de 6-FAM™, VIC™, NED™Más información
Have Questions?
Número de catálogoCantidad
43769111 Kit
Número de catálogo 4376911
Precio (USD)
873,06
Each
Añadir al carro de la compra
Cantidad:
1 Kit
Precio (USD)
873,06
Each
Añadir al carro de la compra
El patrón de instalación DS-33 de GeneScan™ consta de productos de PCR agrupados etiquetados con colorantes de 6-FAM™, VIC™, NED™ y PET™.Para generar los productos agrupados, el ADN genómico individual 1347-02 de CEPH se ha amplificado con 8 pares de cebadores PCR fluorescentes que amplifican los loci de microsatélites seleccionados (como se indica en el prospecto del producto).El kit también contiene un tubo de patrón de tamaño 600 LIZ™ 2.0 de GeneScan™.

Para uso exclusivo en investigación.No diseñado para uso diagnóstico o terapéutico en humanos ni en animales.

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.

Especificaciones
Para utilizar con (equipo)Analizador de ADN 3730xl, analizador genético SeqStudio, analizador genético 3500, analizador de ADN 3730, analizador genético 3500xL
Etiqueta o tinteFAM, LIZ, NED, PET, VIC
Línea de productosGeneScan, LIZ
Tipo de productoPatrón de instalación
Cantidad1 Kit
Condiciones de envíoHielo seco
Tiempo de pruebaEstándar
FormatoTubo
Unit SizeEach
Contenido y almacenamiento
Cada kit contiene cuatro tubos del patrón de instalación DS-33 de GeneScan™ y un tubo del patrón de tamaño 600 LIZ™ v2.0 de GeneScan™.
Almacenar los tubos DS-33 de -25 °C a -15 °C
Almacenar el patrón de tamaño 600 LIZ v2.0 de GeneScan al descongelar entre 2 y 8 °C, proteger de la luz.

Preguntas frecuentes

What does the SeqStudio Starter Kit (PN A35000) contain?

The SeqStudio Starter Kit (PN A35000) includes:
- SeqStudio Integrated Capillary Protector (Cat. No. A31923)
- SeqStudio Cathode Buffer Container (Cat. No. A33401)
- Sequencing Standard, BigDye Terminator v3.1, for 3500/SeqStudio Flex (Cat. No. 4404312)
- DS-33 GeneScan Installation Standards with GeneScan 600 LIZ Size Standard v2.0 (Cat. No. 4376911)
- Hi-Di Formamide (Cat. No. 4401457)
- MicroAmp Optical 96-Well Reaction Plate with Barcode (Cat. No. 4306737)
- MicroAmp 96-Well Tray/Retainer Set (Cat. No. 403081)
- MicroAmp Optical 8-Tube Strip, 0.2 mL (Cat. No. 4316567)
- Nuclease-Free Water (not DEPC-Treated) (Cat. No. AM9930)
- Cathode Buffer Container Reservoir Septa for SeqStudio Genetic Analyzer (Cat. No. A35640)
- 96-well Septa for SeqStudio Genetic Analyzer (Cat. No. A35641)
- 8-strip Septa for SeqStudio Genetic Analyzer (Cat. No. A35643)
- SeqStudio Cartridge v2 (PN A41328) (if this component is ordered online the catalog number is A41331)

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

When I started my run on the Applied Biosystems 3500/3500xL Genetic Analyzer, an error occurred: "Unstable Electrophoresis current detected, check for air bubbles" but I don't see any bubbles. What else can cause this?

Some of the other causes of an Unstable Electrophoresis current detected error message are:

1.Leak on the system
2. Polymer that:
-Has expired
-Has been left on the instrument for more than the recommended time
-Is a mixture of expired polymer and non-expired polymer
3. Running Buffer that was:
-On the instrument longer than 2 weeks
-Not filled to the fill line or evaporated below the fill line
4. An arcing event that was not cleaned afterwards using the water wash wizard
5. Not performing regular maintenance on the instrument
6. Hardware issues

Inspect the system for leaks. If you do not see any leaks on the system, perform the wash the pump chamber and channels wizard using the conditioning pouch and place fresh, non-expired polymer and fresh Anode and Cathode buffer containers. If the problem persists, a service call may be required.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Do I need to replace the buffer every 14 days if the Applied Biosystems 3500/3500xL Genetic Analyzer is not in use?

If the instrument is not in use, it is not necessary to replace the buffer every 14 days. However, the buffer level needs to remain at the fill line to prevent the capillary or array from drying out. Top off the buffer volume with water if necessary. Replace the anode and cathode buffer containers prior to starting a new run.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.