Placas de 96 pocillos Nunc™ FluoroNunc™/LumiNunc™
Placas de 96 pocillos Nunc™ FluoroNunc™/LumiNunc™
Placas de 96 pocillos Nunc™ FluoroNunc™/LumiNunc™
Placas de 96 pocillos Nunc™ FluoroNunc™/LumiNunc™
Placas de 96 pocillos Nunc™ FluoroNunc™/LumiNunc™
Thermo Scientific™

Placas de 96 pocillos Nunc™ FluoroNunc™/LumiNunc™

Use estas placas para inmunoensayos cuantitativos y cualitativos en fase sólida (por ejemplo, FLISA) y ensayos de unión.
Have Questions?
Número de catálogoColor
437796Blanco
Número de catálogo 437796
Precio (USD)
-
Color:
Blanco

Use las placas sólidas de 96 pocillos Thermo Scientific™ Nunc FluoroNunc/LumiNunc para inmunoensayos cuantitativos y cualitativos en fase sólida (por ejemplo, FLISA) y ensayos de unión. Las placas Thermo Scientific Nunc Immuno ofrecen resultados fiables lote a lote y reproducibles pocillo a pocillo, y cuentan con el respaldo de los certificados y patrones de calidad más prestigiosos del sector.

  • Placa con dimensiones SBS adaptable a equipo estándar
  • Disponibilidad de pocillos con fondo plano o en forma de C
  • Selección de superficie PolySorp™ o MaxiSorp™
  • Disponibilidad de placas negras, blancas o transparentes
  • Homogeneidad/reproducibilidad de fijación certificadas

Selección de superficie

  • PolySorp: superficie hidrófoba que une preferentemente biomoléculas con dominios hidrófobos

  • MaxiSorp: superficie hidrófila optimizada para la unión de IgG con una mayor capacidad de unión de muchas otras proteínas y biomoléculas con propiedades hidrófilas/hidrófobas (disponible con o sin un lote específico)

  • Prueba de rendimiento mediante un ensayo de unión de (% de CV de pocillo a pocillo inferior al 5 % para las placas transparentes e inferior al 10 % para las placas de color) (los productos probados incluyen un certificado)

Blanca

  • Ofrece la máxima reflexión
  • Autofluorescencia y autoluminiscencia mínimas

Negra

  • Minimiza el fondo en lecturas de fluorescencia
  • Minimiza la luz con retrodispersión
  • Minimiza la diafonía

Transparente

  • Para fluorescencia resuelta en el tiempo

Compatible con:

Compatible con tapas para placas MicroWell™, cinta de sellado y membrana transpirable

Especificaciones
Propiedad de uniónHidrófilo
Tipo de enlaceAdsorción
Certificaciones/conformidadCon certificado para la absorción de IgG; % de CV de pocillo a pocillo inferior al 10 %.
Área de cultivo2,5 cm2
Método de detecciónQuimioluminiscencia
TapaCon tapa
N.º por caja60
N.° por paquete5
Envase60 cajas
Bloqueo de placasNinguno
Tipo de productoMicroplaca
Molécula dianaAnticuerpos (glucoproteínas)
Volumen de trabajo (métrico)250 μl
matriz, red, conjunto8 x 12
ColorBlanco
FormatoEstándar
MaterialPoliestireno
N.° de pocillos96
Línea de productosNunc
Tratamiento de superficieMaxiSorp
Forma del pocilloRedondo
Unit SizeCase of 60

Preguntas frecuentes

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.

How can I reduce high background readings and non-specific binding, when performing ELISA using Nunc-Immuno MaxiSorp Plates?

Assay sensitivity depends strongly on efficient removal of non-specific reacting molecules. High background readings and coating instability can be minimized by addition of a blocking step after the first coating. The excess surface is then occupied by indifferent molecules.
We recommend washing three times after each coating step by using a solution of 0.15 M phosphate buffer (pH 7.2) with 0.2 M NaCl and 0.05% Tween 20.
For blocking, we recommend using 0.5% BSA, 1% casein or 1% gelatin in 0.15 M phosphate buffer (pH 8.2) or carbonate buffer (pH 9.6).