PrimeFlow™ 96-well plate 10 packets
Product Image
Invitrogen™

PrimeFlow™ 96-well plate 10 packets

Estas placas PrimeFlow™ de 96 pocillos son placas de poliestireno con fondo en V validadas para su uso con elMás información
Have Questions?
Número de catálogoCantidad
44-17005-4610 Packets
Número de catálogo 44-17005-46
Precio (USD)
-
Cantidad:
10 Packets
Estas placas PrimeFlow™ de 96 pocillos son placas de poliestireno con fondo en V validadas para su uso con el ensayo de ARN PrimeFlow™.

Aplicación declarada
Citometría de flujo de ARN

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Método de detecciónColorimétrico
Envase10 paq.
Bloqueo de placasNinguno
Tipo de productoMicroplaca
Cantidad10 Packets
ColorTransparente
MaterialPoliestireno
N.° de pocillos96
Línea de productosPrimeFlow
Forma del pocilloV
Unit Size10 Packets

Preguntas frecuentes

Can the FlowRNA Assay be adapted to a 96-well protocol? Do you have a protocol for this?

Yes. We have a validated protocol for Flow RNA assay in 96-wells. Please see Appendix 7 of Cat. No. 88-18005 for the protocol.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

When running the QuantiGene FlowRNA (methanol based) assay, which fluorochromes are recommended for antibody staining?

We recommend the use of fluorochromes that are known to be methanol resistant. Avoid protein-based fluorochromes such as APC, PE, and PerCP and their respective tandems. This question is not appropriate for PrimeFlow RNA Assay.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

For the PrimeFlow RNA Assay, how would you recommend I set compensation?

We recommend using the PrimeFlow Compensation Kit included in the PrimeFlow RNA Assay (Cat. No. 88-18005-204, 88-18005-210) to set compensation for each RNA channel. Refer to Appendix 3 of the PrimeFlow RNA Assay User Manual for detailed instructions for use. The UltraComp eBeads microspheres included in the compensation kit may also be used for any experimental antibodies being used. Antibodies with the same fluorochromes as the RNA probes should not be used to set compensation for RNA probes, as the compensation values will be different.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I have a 37 degrees C tissue culture incubator in the lab. Can I use this incubator for the hybridization steps in the PrimeFlow RNA Assay protocol?

The hybridization temperature is a critical parameter of this protocol necessary to obtain positive results. The incubator to be used must be validated before use with the ViewRNA Temperature Validation Kit (Cat. No. QV0523), following the protocol in the FlowRNA user manual. Temperatures deviated outside of this range will lead to less-than-optimal hybridization.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What type of 96-well plate is compatible with the PrimeFlow RNA protocol?

We recommend polystyrene uncoated v-bottom 96-well plates with a lid (Cat. No. 44-17005-46). The u-bottom plate is also acceptable, but flat bottom plates are not recommended.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.