Megaplex™ Primer Pools, Human Pools Set v3.0 está disponible con un solo número de pieza que contiene Megaplex™ RT PrimersMás información
Have Questions?
Número de catálogo
Cantidad
4444750
50 reacciones
Número de catálogo 4444750
Precio (USD)
1.807,44
Each
Añadir al carro de la compra
Cantidad:
50 reacciones
Precio (USD)
1.807,44
Each
Añadir al carro de la compra
Megaplex™ Primer Pools, Human Pools Set v3.0 está disponible con un solo número de pieza que contiene Megaplex™ RT Primers Human Pool A v2.1, Megaplex™ RT Primers Human Pool B v3.0, Megaplex™ PreAmp Primers, Human Pool A v2.1 y Megaplex™ PreAmp Primers, Human Pool B v3.0.Megaplex™ primer Pools, Human Pools Set v3.0 contiene cebadores de RT para 754 microRNA únicos y 4 controles.Para su uso cuando la sensibilidad del ensayo es de la máxima importancia, los cebadores Megaplex™ PreAmp mejoran significativamente la capacidad de detectar microARN de baja expresión, lo que permite generar un perfil de expresión completo utilizando mucha menos muestra, tan solo 1 ng del ARN total de entrada.Megaplex™ primer Pools, Human Pools Set v3.0 está diseñado para usarse con la matriz TaqMan® Human MicroRNA Card Set v3.0, aunque también puede usarse para preparar el ADNc para análisis en tiempo real utilizando los ensayos individuales de microARN de TaqMan®.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Características ecológicasEmbalaje sostenible
N.º de reacciones50 reacciones
CebadorCebadores RT, cebadores PreAmp
Línea de productosMegaplex
Tipo de productoGrupo de primers
Cantidad50 reacciones
EspecieHumano
Suficiente para50 reacciones
Para utilizar con (aplicación)Análisis de miARN
GC-Rich PCR PerformanceBajo
Método de PCRqPCR
Unit SizeEach
Contenido y almacenamiento
Almacenar a -20°C
Preguntas frecuentes
Can Ct's greater than a cut-off be considered valid results?
Yes they can. However, it is important to recognize the true linearity and detection limits of your assay: Ct values above the cut-off can indicate non-specific amplification, unless your NTC is a true- no-target control, and you have run a statistically significant number of replicates. Any results with Ct above the recommended cut-off need to be validated with individual assays on plates.
What is a good Ct cut-off for the TaqMan MicroRNA Array Cards and TaqMan Advanced miRNA Array Cards? In other words, beyond what Ct should I not trust the data?
The typical Ct cut-off on TaqMan Array Cards is 32, which is equivalent to Ct 35 on a plate (10 µl reaction). Previous studies show that if you use pre-amplification, a Ct cut-off of 29 or 30 can be used to reduce numbers of false positives (see Technical Note Optimized protocols for human or rodent microRNA profiling with precious samples). To ensure that you have selected a correct cut-off, you should run replicates of the same sample and use Ct cut-off before you see an increase in the Standard Deviation.
Why are the Ct values for my endogenous controls are highly variable across the sample set?
Highly variable values for endogenous controls is most likely due to biological variation. Use an alternative endogenous control such as a non-variable miRNA.
Why is the Ct value for the No Template Control (NTC) <35 for some assays?
Please review the following possible causes and solutions:
- There are non-specific interactions between primers. For NTC information on a specific assay, refer to the Megaplex Assay Performance File.
- The cDNA template is contaminated. Please follow established PCR good laboratory practices.
- The preamplification product was not diluted properly before real-time PCR. Follow the recommendations in the protocol. Please see "Dilute the preamplification reaction" on page 18.
Why did I not detect any miRNA?
It is possible that the threshold is set too high to detect miRNA in samples with low expression. Identify an appropriate NOAMP flag threshold if the relative threshold algorithm (Crt) is used. Alternatively, identify an appropriate threshold if Ct is used.