Tampón de lavado de inmunotransferencia (Western blot) Restore™ PLUS
Tampón de lavado de inmunotransferencia (Western blot) Restore™ PLUS
Thermo Scientific™

Tampón de lavado de inmunotransferencia (Western blot) Restore™ PLUS

Thermo Scientific Restore PLUS Western Blot Stripping Buffer es una fórmula avanzada para la extracción de anticuerpos primarios y secundariosMás información
Have Questions?
Número de catálogoCantidad
46430500 ml
Número de catálogo 46430
Precio (USD)
322,38
Each
Añadir al carro de la compra
Cantidad:
500 ml
Pedido a granel o personalizado
Precio (USD)
322,38
Each
Añadir al carro de la compra
Thermo Scientific Restore PLUS Western Blot Stripping Buffer es una fórmula avanzada para la extracción de anticuerpos primarios y secundarios unidos de membranas de manera que se les pueda volver a aplicar sondas y detectar con sustratos quimioluminiscentes.

Características de Restore PLUS Western Blot Stripping Buffer:

Sencillo de utilizar y listo para su uso: no es necesaria ninguna dilución; sin olores desagradables; almacenamiento a temperatura ambiente
Compatible: utilícelo en membranas de nitrocelulosa y fluoruro de polivinilideno (PVDF), tanto si sigue húmedo como si ya está seco; funciona con casi cualquier tampón bloqueante, conjugado de enzimas y sustrato quimioluminiscente
Rentable: ahorre tiempo y muestras valiosos; lave blots de manera eficaz la primera vez
Resistente pero suave:las proteínas transferidas siguen siendo viables; lave el mismo blot hasta cinco veces
Flexible: lave y vuelva a aplicar sondas para optimizar las concentraciones de anticuerpos o para detectar un antígeno nuevo con diferentes anticuerpos

El tampón Restore PLUS es una formulación alternativa del tampón de lavado de inmunotransferencia Thermo Scientific Restore original. El tampón de lavado Restore PLUS se ha diseñado para su uso con anticuerpos que resultan difíciles de extraer de las inmunotransferencias y que requieren mayores tiempos de incubación y temperaturas de incubación superiores a 22 °C con formulaciones más suaves. Los anticuerpos de alta afinidad se pueden extraer con rapidez y eficacia de las inmunotransferencias a temperatura ambiente sin eliminar las proteínas transferidas, por lo que permite volver a aplicar varias sondas al objetivo.

Resumen del protocolo:
• Lave el blot para eliminar el sustrato quimioluminiscente
• Incube el blot en el tampón de lavado de inmunotransferencia (Western Blot) Restore de 5 a 15 minutos a temperatura ambiente
(o incube a 37 °C para anticuerpos de alta afinidad)
• Extraiga el blot y lave en el tampón de lavado
• Bloquee la membrana
• Compruebe si la extracción de anticuerpos es suficiente
• Realice el siguiente experimento de inmunoblot

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.

Especificaciones
Método de detecciónQuimioluminiscente
Para utilizar con (aplicación)Western Blot
FormularioLíquido
Membrane CompatibilityNitrocelulosa, PVDF
Línea de productosRestore
Tipo de productoTampón de separación de inmunotransferencia Western Blot
Cantidad500 ml
Unit SizeEach
Contenido y almacenamiento
Tras la recepción, guarde el producto a temperatura ambiente. Producto enviado a temperatura ambiente.

Preguntas frecuentes

How many times can I strip my blot using Restore or Restore Plus Western Blot Stripping Buffers ?

The stability of the attached (transferred and bound) protein will determine the number of times the membrane can be successfully re-probed after stripping. The protein may withstand stripping as many as four times or as few as one time.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

What is the proper wash buffer to use after stripping with Restore or Restore Plus Western Blot Stripping buffers?

Wash the membrane with the same buffer as was used between antibody probing steps during the Western blotting procedure.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Can I strip membranes with Restore or Restore Plus Western Blot Stripping Buffer and reprobe for subsequent detection with fluorescent probes?

No. Although the fluorescent antibodies, like other antibodies, can be stripped with Restore Buffers, stripped membranes typically produce unacceptable background for subsequent fluorescent detection methods. We recommend Restore Fluorescent Western Blot Stripping Buffer, Cat. No. 62299 (20 mL) and Cat. No. 62300 (100 mL).

Note: Restore Fluorescent Western Blot Stripping Buffer is for use with low-fluorescence PVDF membrane (Cat. No. 22860) only.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Will Restore and Restore Plus Western Blot Stripping Buffers remove biotin-bound avidin, streptavidin or NeutrAvidin Protein conjugates?

No. Restore and Restore Plus Buffers are not stringent enough to break the avidin-biotin interaction. A buffer capable of breaking this interaction would likely also damage the target protein, making it undetectable. However it may be possible to strip the complexed biotinylated primary antibody and streptavidin-HRP secondary antibody from the target protein on the membrane. Please also see Tech Tip: Strip and Reprobe Western Blots (https://assets.thermofisher.com/TFS-Assets/BID/Technical-Notes/strip-reprobe-western-blots-tech-tip.pdf).

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

Will the Restore and Restore Plus Western Blot Stripping Buffers remove precipitating substrates?

No. The antibodies are removed but the substrate leaves a permanent precipitate on the membrane that cannot be removed. Restore and Restore Plus Buffers are designed for procedures using chemiluminescent substrates. Please note that this is not compatible with fluorescence supstrates as it will result in increased background. For fluorescent substrates please use our Restore Fluorescent Western Blot Stripping Buffer. Please also see Tech Tip: Strip and Reprobe Western Blots (https://assets.thermofisher.com/TFS-Assets/BID/Technical-Notes/strip-reprobe-western-blots-tech-tip.pdf).

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.