CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column
CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column
Thermo Scientific™

CaptureSelect™ CH1-XL RoboColumn™ Pre-packed Column

Thermo Scientific™ CaptureSelect™ RoboColumn™ small chromatography columns are used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoCapacidad (métrico)
5943462200200 μL
5943462600600 μl
Número de catálogo 5943462200
Precio (USD)
-
Capacidad (métrico):
200 μL

CaptureSelect RoboColumn™ small chromatography columns are used for fully automated and parallel chromatographic separations on robotic liquid handling workstations.

CaptureSelect CH1-XL Affinity Matrix recognizes the CH1 domain of human IgG antibodies, thereby enabling purification of all Fab fragments, independent of the light-chain type (kappa or lambda) and without binding of over-expressed light chain and light-chain dimers. In addition, it can be used for the purification of human IgGs from all four subclasses (1, 2, 3, and 4).

Features of this affinity matrix include:

  • Platform approach for purification of high quality and correctly assembled human Fab fragments
  • No co-purification of over-expressed free light chains due to selectivity for the CH1 domain
  • Elution possible at pH 4.0–4.5 with 50 mM acetate buffer
  • Caustic cleaning with up to 50 mM NaOH
  • Excellent scalability
  • No cross-binding to bovine IgG, therefore presence of fetal bovine serum is not a problem
  • Non-animal-derived

Free of animal components

CaptureSelect products contain affinity ligands based on recombinant single-domain antibody fragments (VHH) created by a proprietary technology. The VHH affinity ligand is a 12 to 15 kDa fragment comprising the three complementarity-determining regions (CDRs) that form the antigen-binding domain, efficiently produced in the yeast Saccharomyces cerevisiae by a production process free of any animal components (Animal Origin-Free).

Characteristics

  • Column size: 200 μL and 600 μL, 1 strip, 8 columns (8-row)
  • Column dimension: 200 μL: 5 x 10 mm
  • Column dimension: 600 μL: 5 x 30 mm
  • Matrix: agarose based, epoxide-activated
  • Average particle size: 65 ± 10 μm
  • Ligand: CaptureSelect CH1-XL affinity ligand
  • Ligand coupling: epoxide coupling
  • Binding capacity: >15 mg/mL human Fab fragment depending on flow rate, column height, contact time. For humanized Fabs, lower capacities may be observed.
  • Elution conditions: 100 mM glycine buffer, pH 3.0; 50 mM acetate buffer, pH 4.0–4.5
  • Formulation buffer: 20% (v/v) ethanol
  • Operating pressure: 2 bar (maximum)
  • Flow rate: 16–150 cm/h

RoboColumn is a trademark of Repligen.

For Research Use Only. Not for use in diagnostic procedures.
Especificaciones
Capacidad de unión>15 mg/mL human Fab fragment
Tipo de columnaRoboColumn
Diámetro (métrico)5 mm
Caudal16 to 150 cm/hr.
Para utilizar con (aplicación)Chromatography
Formato8-well Strips
Longitud (métrico)10 mm
Tipo de ligandoCH1-XL affinity ligand
MatrizAgarose-based, epoxide-activated
Presión máx. de funcionamiento2 bar
Cantidad200 μL
Condiciones de envíoRoom temperature, or on wet ice
Fase estacionariaCH1-XL affinity ligand on agarose bead
Capacidad (métrico)200 μL
Tamaño de partículas65 ±10 μm
Línea de productosCaptureSelect
TipoColumn
Unit SizeEach
Contenido y almacenamiento
Store in refrigerator (2°C to 8°C)