Specifications
- Current Range: 0.1 to 100A DC or 0.1 to 70A AC
- Basic Accuracy (DC to 1kHz):
- 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA
- 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA
- 40A to 80A +/- 12% of reading + 50mA
- 80 to 100A +/- 15% of reading
- Output Signal: 10A range: 100mV/A ∣ 100A range: 10mV/A
- Bandwidth: 1Hz to 20kHz
- Working Voltage: 600V AC rms
- Maximum Conductor Size: 11.8 mm (.46 inch) diameter
- Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V
- Nominal current range:
- Continuous current range:
- 0.1 A - 10 A AC/DC
- 1 A - 100 A AC/DC
- Maximum non-destructive current: 140 A - 2 kHz
- Lowest measurable current: 0.1 A
- Basic accuracy:
- 100 mV/A setting: 50 mA to 10 A ±3% of reading +50 mA
- 10 mV/A setting: 50 mA to 40 A ±4% of reading +50 mA
- 40 A to 80 A ±12% of reading +50 mA
- 80 to 100 A ±15% of reading
- Useable frequency: DC - 100 kHz
- Output level(s):
- 10 A range: 100 mV/A
- 100 A range: 10 mV/A
- Zero error adjustment: Yes
Safety Specifications
- CAT II, 600 V
- CAT III, 300 V
- Maximum voltage: 600 V
Mechanical and General Specifications
- Battery life: 9 V, 55 h
- Maximum conductor diameter: 11.8 mm
- Output cable length: 1.6 m
- BNC adapter: Yes