| 60180-805 | Full specifications | Each | Triple Filter - Moisture, Oxygen, Hydrocarbons | For gas: Inert carrier, He, H2, N2, AR | 6 g H2O, 1 L O2, 12 g HCs (as n-butane) | Contact Us › |
For Use With (Equipment) | Inert Carrier, He, H2, N2, AR | Volume (Metric) | 6 g H2O, 1 L O2, 12 g HCs (as n-butane) | Description | For gas: Inert carrier, He, H2, N2, AR | For Use With (Application) | GC/LC | Type | Triple Filter - Moisture, Oxygen, Hydrocarbons | Unit Size | Each |
|
| 60180-801 | Full specifications | Each | Moisture Filter | For gas: Inert carrier, He, H2, N2, AR, Air | 21 g H2O | Contact Us › |
For Use With (Equipment) | Inert Carrier, He, H2, N2, AR, Air | Volume (Metric) | 21 g H2O | Description | For gas: Inert carrier, He, H2, N2, AR, Air | For Use With (Application) | GC/LC | Type | Moisture Filter | Unit Size | Each |
|
| 60180-802 | Full specifications | Each | Oxygen Filter | For gas: Inert carrier, He, H2, N2, AR | 3 L O2 | Contact Us › |
For Use With (Equipment) | Inert Carrier, He, H2, N2, AR | Volume (Metric) | 3 L O2 | Description | For gas: Inert carrier, He, H2, N2, AR | For Use With (Application) | GC/LC | Type | Oxygen Filter | Unit Size | Each |
|
| 60180-803 | Full specifications | Each | Hydrocarbon Filter | For gas: Inert carrier, He, H2, N2, AR, Air | 36 g (as n-butane) | Contact Us › |
For Use With (Equipment) | Inert Carrier, He, H2, N2, AR, Air | Volume (Metric) | 36 g (as n-butane) | Description | For gas: Inert carrier, He, H2, N2, AR, Air | For Use With (Application) | GC/LC | Type | Hydrocarbon Filter | Unit Size | Each |
|
| 60180-804 | Full specifications | Each | Combi Filter - Moisture, Oxygen | For gas: Inert carrier, He, H2, N2, AR | 10 g H2O, 1.5 L O2 | Contact Us › |
For Use With (Equipment) | Inert Carrier, He, H2, N2, AR | Volume (Metric) | 10 g H2O, 1.5 L O2 | Description | For gas: Inert carrier, He, H2, N2, AR | For Use With (Application) | GC/LC | Type | Combi Filter - Moisture, Oxygen | Unit Size | Each |
|
| 60180-806 | Full specifications | Each | Triple Filter - Moisture, Oxygen, Hydrocarbons - He Preconditioned for GC/MS | For gas: He | 6 g H2O, 1 L O2, 12 g HCs (as n-butane) | Contact Us › |
For Use With (Equipment) | He | Volume (Metric) | 6 g H2O, 1 L O2, 12 g HCs (as n-butane) | Description | For gas: He | For Use With (Application) | GC/LC | Type | Triple Filter - Moisture, Oxygen, Hydrocarbons - He Preconditioned for GC/MS | Unit Size | Each |
|
| 60180-808 | Full specifications | Each | Indicating Triple Filter - Moisture, Oxygen, Hydrocarbons - He Preconditioned for GC/MS | For gas: He | 0.1 g H2O, 100 mL O2, 0.07 g HCs (as n-butane) | Contact Us › |
For Use With (Equipment) | He | Volume (Metric) | 0.1 g H2O, 100 mL O2, 0.07 g HCs (as n-butane) | Description | For gas: He | For Use With (Application) | GC/LC | Indicator Change | Moisture: Yellow to Clear; Oxygen: Green to Gray | Type | Indicating Triple Filter - Moisture, Oxygen, Hydrocarbons - He Preconditioned for GC/MS | Unit Size | Each |
|
| 60180-843 | Full specifications | Each | Combi Filter - Moisture, Hydrocarbons | For gas: Inert carrier, He, H2, N2, AR, Air | 10 g H2O, 18 g HCs (as n-butane) | Contact Us › |
For Use With (Equipment) | Inert Carrier, He, H2, N2, AR, Air | Volume (Metric) | 10 g H2O, 18 g HCs (as n-butane) | Description | For gas: Inert carrier, He, H2, N2, AR, Air | For Use With (Application) | GC/LC | Type | Combi Filter - Moisture, Hydrocarbons | Unit Size | Each |
|