Catalog Number
912A0888
Unit Size
Each
Description
Evolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Price (BRL)
Full specifications
Baseline Flatness±0.0010 A, 200 to 800 nm, 1.0 nm SBW, smoothing
Certifications/ComplianceISO 9001:2008
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel, 800 x 480 pixels, 17.8 cm (7 in. diagonal)
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in.)
Spectral BandwidthVariable: 1.0 nm, 2.0 nm
Wavelength Range190 to 1100 nm
Drift<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup
Electrical Requirements100/240 V, 50/60 Hz selected automatically, 150 W maximum
For Use With (Application)Spectroscopy Elemental Isotope Analysis
KeypadSealed membrane
Lamp Life7 years typical
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002 A
ProcessorMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1 to 6000 nm/min. (Variable)
Warranty3 Years
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Weight (Metric)14.4 kg
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (BRL)
912A0888Full specifications
EachEvolution 260 Bio Spectrophotometer plus Tablet Control Module - InternationalContact Us ›
Baseline Flatness±0.0010 A, 200 to 800 nm, 1.0 nm SBW, smoothing
Certifications/ComplianceISO 9001:2008
DescriptionEvolution 260 Bio Spectrophotometer plus Tablet Control Module - International
Detector TypeDual Silicon Photodiodes
DisplayTouchscreen LCD panel, 800 x 480 pixels, 17.8 cm (7 in. diagonal)
Dimensions (L x W x H)62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in.)
Spectral BandwidthVariable: 1.0 nm, 2.0 nm
Wavelength Range190 to 1100 nm
Drift<0.0005 A/hr., 500 nm, 1.0 nm SBW, 1 hr. warmup
Electrical Requirements100/240 V, 50/60 Hz selected automatically, 150 W maximum
For Use With (Application)Spectroscopy Elemental Isotope Analysis
KeypadSealed membrane
Lamp Life7 years typical
Noise0A: <0.00015A
1A: <0.00025A
2A: <0.00080A
260nm, 1.0nm SBW, RMS
Optical DesignDouble Beam with sample and reference cuvette positions; Application Focused Beam Geometry; Czerny-Turner Monochromator
Pharmacopoeia Compliance Testing(Guaranteed Performance Specifications)
Resolution (toluene in Hexane): ≥1.8A
Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A
Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, KI
Wavelength Accuracy: ±0.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range
Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line
Photometric Display-0.3 - 4.0A
Photometric Range>3.5A
Photometric Repeatability±0.0002 A
ProcessorMicrosoft Windows™ XP embedded
INSIGHT 2 Software is also compatible with Windows 7 and Windows 8.1 Professional Editions and can be installed on a computer attached to the instrument
Scan Ordinate ModesAbsorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R), log (Abs), Abs*Factor, Intensity
Scan Speed<1 to 6000 nm/min. (Variable)
Warranty3 Years
Wavelength Accuracy±0.5 nm (541.9, 546.1 nm mercury lines), ±0.8 nm (full range 190 to 1100 nm)
Wavelength Data Interval10, 5, 2, 1.0, 0.5, 0.2, 0.1 nm
Weight (Metric)14.4 kg
Unit SizeEach