Thermo Scientific™

Dionex™ CR-TC Continuously Regenerated Trap Columns

Número do catálogo: 060477
Thermo Scientific™

Dionex™ CR-TC Continuously Regenerated Trap Columns

Número do catálogo: 060477

Remove ionic contaminants from eluents continuously, without the need for offline chemical regeneration. Thermo Scientific™ Dionex™ CR-TC Continuously Regenerated Trap Columns are electrolytically regenerated trap columns specifically designed for Reagent-Free™ ion chromatography (RFIC™) systems. When plumbed after the Thermo Scientific™ Dionex™ EGC Eluent Generation Cartridge, the Dionex CR-TC trap column removes all ionic contaminants from the deionized feed water, providing low drift during gradient operations.

 
Número do catálogo
060477
Tamanho da unidade
Each 1
Description
Dionex™ CR-ATC Continuously Regenerated Anion Trap Column
For Use With (Equipment)
Standard Anion Capillary RFIC Systems up to 3,000 psi
Especificações completas
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard Anion Capillary RFIC Systems up to 3,000 psi
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size55 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-ATC (Capillary) Continuously Regenerated Anion Trap Column
For Use With (Equipment)
Standard Anion Capillary RFIC Systems
Especificações completas
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC (Capillary) Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard Anion Capillary RFIC Systems
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size55 μm
FormatCapillary
Void Volume (Metric)<2 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-ATC 500 Continuously Regenerated Anion Trap Column
For Use With (Equipment)
All Anion, RFIC, and HPIC Systems that are Not Consumables Monitoring Enabled
Especificações completas
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC 500 Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)All Anion, RFIC, and HPIC Systems that are Not Consumables Monitoring Enabled
HydrophobicityLow
Particle Size55 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-CTC II Continuously Regenerated Cation Trap Column
For Use With (Equipment)
Standard RFIC Systems That Operate up to 3,000 psi
Especificações completas
Column TypeCation Trap Column
Crosslinking15 to 20% DVB
DescriptionDionex™ CR-CTC II Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard RFIC Systems That Operate up to 3,000 psi
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size17 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-CTC (Capillary) Continuously Regenerated Cation Trap Column
For Use With (Equipment)
Standard Cation Capillary RFIC Systems
Especificações completas
Column TypeCation Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-CTC (Capillary) Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard Cation Capillary RFIC Systems
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size55 μm
FormatCapillary
Void Volume (Metric)<2 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-ATC 600 Continuously Regenerated Anion Trap Column
For Use With (Equipment)
Dionex ICS-6000 and Dionex Integrion Systems
Especificações completas
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC 600 Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex ICS-6000 and Dionex Integrion Systems
HydrophobicityLow
Particle Size55 μm
Void Volume (Metric)<2 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-CTC 600 Continuously Regenerated Cation Trap Column
For Use With (Equipment)
Dionex ICS-6000 and Dionex Integrion Systems
Especificações completas
Column TypeCation Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-CTC 600 Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex ICS-6000 and Dionex Integrion Systems
HydrophobicityLow
Particle Size55 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each 1
Description
Dionex™ CR-CTC 500 Continuously Regenerated Cation Trap Column
For Use With (Equipment)
Dionex HPIC Systems that are Not Consumables Monitoring Enabled
Especificações completas
Column TypeCation Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-CTC 500 Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex HPIC Systems that are Not Consumables Monitoring Enabled
HydrophobicityLow
Particle Size50 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
Número do catálogo
Tamanho da unidade
Each
Description
Dionex™ CR-CTC III Continuously Regenerated Cation Trap Column
For Use With (Equipment)
Dionex ICS-6000 and Dionex Integrion Systems
Especificações completas
Column TypeCation Trap Column
Crosslinking15 to 20% DVB
DescriptionDionex™ CR-CTC III Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex ICS-6000 and Dionex Integrion Systems
HydrophobicityLow
Particle Size17 μm
Void Volume (Metric)<100 μL
Unit SizeEach
Mostrando 9 de 9
Número do catálogoEspecificaçõesTamanho da unidadeDescriptionFor Use With (Equipment)Preço (BRL)
060477Especificações completas
Each 1Dionex™ CR-ATC Continuously Regenerated Anion Trap ColumnStandard Anion Capillary RFIC Systems up to 3,000 psiEntre em contato ›
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard Anion Capillary RFIC Systems up to 3,000 psi
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size55 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
072078Especificações completas
Each 1Dionex™ CR-ATC (Capillary) Continuously Regenerated Anion Trap ColumnStandard Anion Capillary RFIC SystemsEntre em contato ›
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC (Capillary) Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard Anion Capillary RFIC Systems
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size55 μm
FormatCapillary
Void Volume (Metric)<2 μL
Unit SizeEach 1
075550Especificações completas
Each 1Dionex™ CR-ATC 500 Continuously Regenerated Anion Trap ColumnAll Anion, RFIC, and HPIC Systems that are Not Consumables Monitoring EnabledEntre em contato ›
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC 500 Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)All Anion, RFIC, and HPIC Systems that are Not Consumables Monitoring Enabled
HydrophobicityLow
Particle Size55 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
066262Especificações completas
Each 1Dionex™ CR-CTC II Continuously Regenerated Cation Trap ColumnStandard RFIC Systems That Operate up to 3,000 psiEntre em contato ›
Column TypeCation Trap Column
Crosslinking15 to 20% DVB
DescriptionDionex™ CR-CTC II Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard RFIC Systems That Operate up to 3,000 psi
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size17 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
072079Especificações completas
Each 1Dionex™ CR-CTC (Capillary) Continuously Regenerated Cation Trap ColumnStandard Cation Capillary RFIC SystemsEntre em contato ›
Column TypeCation Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-CTC (Capillary) Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Standard Cation Capillary RFIC Systems
HydrophobicityLow
Max. Pressure3000 psi (207 bar)
Particle Size55 μm
FormatCapillary
Void Volume (Metric)<2 μL
Unit SizeEach 1
088662Especificações completas
Each 1Dionex™ CR-ATC 600 Continuously Regenerated Anion Trap ColumnDionex ICS-6000 and Dionex Integrion SystemsEntre em contato ›
Column TypeAnion Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-ATC 600 Continuously Regenerated Anion Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex ICS-6000 and Dionex Integrion Systems
HydrophobicityLow
Particle Size55 μm
Void Volume (Metric)<2 μL
Unit SizeEach 1
088663Especificações completas
Each 1Dionex™ CR-CTC 600 Continuously Regenerated Cation Trap ColumnDionex ICS-6000 and Dionex Integrion SystemsEntre em contato ›
Column TypeCation Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-CTC 600 Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex ICS-6000 and Dionex Integrion Systems
HydrophobicityLow
Particle Size55 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
075551Especificações completas
Each 1Dionex™ CR-CTC 500 Continuously Regenerated Cation Trap ColumnDionex HPIC Systems that are Not Consumables Monitoring EnabledEntre em contato ›
Column TypeCation Trap Column
Crosslinking8% DVB
DescriptionDionex™ CR-CTC 500 Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex HPIC Systems that are Not Consumables Monitoring Enabled
HydrophobicityLow
Particle Size50 μm
Void Volume (Metric)<100 μL
Unit SizeEach 1
104-60001Especificações completas
EachDionex™ CR-CTC III Continuously Regenerated Cation Trap ColumnDionex ICS-6000 and Dionex Integrion SystemsEntre em contato ›
Column TypeCation Trap Column
Crosslinking15 to 20% DVB
DescriptionDionex™ CR-CTC III Continuously Regenerated Cation Trap Column
For Use With (Application)Removal of Ionic Contaminants from Eluents Without the Need for Off-Line Chemical Regeneration
For Use With (Equipment)Dionex ICS-6000 and Dionex Integrion Systems
HydrophobicityLow
Particle Size17 μm
Void Volume (Metric)<100 μL
Unit SizeEach
Mostrando 9 de 9
Meet Today's Demands in Ion Chromatography

Dionex CR-TC columns:

  • Increase productivity
  • Provide very low baseline drift for improved integration and increased sensitivity
  • Provide contaminant-free deionized source water and eluents

Which Dionex CR-TC column to use with which IC system:

  • Use Dionex CR-ATC and CR-CTC II columns on standard RFIC systems that operate up to 3,000psi
  • Use Dionex CR-TC 500 columns on all RFIC and high-pressure IC (HPIC) systems that operate up to 5,000psi. You can use the Dionex CR-TC 500 column in place of the Dionex CR-ATC and CR-CTC II column
  • Use capillary Dionex CR-TC columns on capillary RFIC systems; do not use capillary Dionex CR-TC columns on analytical-scale RFIC systems
  • Use the Dionex CR-TC 600 and CR-CTC columns on the Thermo Scientific™ Dionex™ Integrion™ HPIC™ and Thermo Scientific™ Dionex™ ICS-6000 HPIC Systems only

Remove Cationic Contaminants with Dionex CR-CTC III Columns

Dionex CR-CTC III Continuously Regenerated Cation Trap columns are high-pressure electrolytically regenerated trap columns designed for use with eluent generator devices and compatible with Dionex Integrion and Dionex ICS-6000 HPIC systems

The Dionex CR-CTC III offers:

  • Contaminant-free deionized source water and eluent
  • Time savings; no need to perform regeneration offline
  • Very low baseline drift for improved integration and increased sensitivity
  • Increased productivity; quality data soon after startup
  • Removal of cationic impurities from source water
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figuras

Documentos e downloads

Certificados

    Perguntas frequentes

    Citações e referências

    Search citations by name, author, journal title or abstract text