Thermo Scientific™

GlycanPac™ AXR-1 HPLC Columns

Número do catálogo: 088135
Thermo Scientific™

GlycanPac™ AXR-1 HPLC Columns

Número do catálogo: 088135

Get industry-leading, ultra-high resolution of labeled and native glycans for structural characterization and quantification using the Thermo Scientific™ GlycanPac™ AXR-1 LC Columns. This high-performance, silica-based chromatography column achieves mixed-mode separation using a combination of charge, isomer structure, and size. Now there's a column with unique selectivity to analyze biologically important glycans. The GlycanPac AXR-1 column is available in multiple HPLC and UHPLC formats and is compatible with fluorescence or mass spectrometry (MS) detection.

 
Número do catálogo
088135
Tamanho da unidade
Each
Particle Size
1.9 μm
Diameter (Metric)
2.1 mm
Length (Metric)
250 mm
Especificações completas
Column ChemistryWAX and RP Mixed Mode
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.2 to 0.4 mL/min
Length (Metric)250 mm
Max. Pressure15000 psi (1035 bar)
Particle ShapeSpherical, high purity, porous
Particle Size1.9 μm
pH2 to 8
Pore Size175 Å
SolventsCompatible with 0 to 100% aqueous and common HPLC solvents
Surface Area220 m²/g
Temperature60°C
Stationary PhaseProprietary
Product LineGlycanPac
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeMixed Mode
PhaseReversed Phase and Ion Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Particle Size
1.9 μm
Diameter (Metric)
2.1 mm
Length (Metric)
150 mm
Especificações completas
Column ChemistryWAX and RP Mixed Mode
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.2 to 0.4 mL/min
Length (Metric)150 mm
Max. Pressure10000 psi (690 bar)
Particle ShapeSpherical, high purity, porous
Particle Size1.9 μm
pH2 to 8
Pore Size175 Å
SolventsCompatible with 0 to 100% aqueous and common HPLC solvents
Surface Area220 m²/g
Temperature60°C
Stationary PhaseProprietary
Product LineGlycanPac
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeMixed Mode
PhaseReversed Phase and Ion Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
Mostrando 2 de 2
Número do catálogoEspecificaçõesTamanho da unidadeParticle SizeDiameter (Metric)Length (Metric)Preço (BRL)
088135Especificações completas
Each1.9 μm2.1 mm250 mmEntre em contato ›
Column ChemistryWAX and RP Mixed Mode
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.2 to 0.4 mL/min
Length (Metric)250 mm
Max. Pressure15000 psi (1035 bar)
Particle ShapeSpherical, high purity, porous
Particle Size1.9 μm
pH2 to 8
Pore Size175 Å
SolventsCompatible with 0 to 100% aqueous and common HPLC solvents
Surface Area220 m²/g
Temperature60°C
Stationary PhaseProprietary
Product LineGlycanPac
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeMixed Mode
PhaseReversed Phase and Ion Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
088136Especificações completas
Each1.9 μm2.1 mm150 mmEntre em contato ›
Column ChemistryWAX and RP Mixed Mode
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.2 to 0.4 mL/min
Length (Metric)150 mm
Max. Pressure10000 psi (690 bar)
Particle ShapeSpherical, high purity, porous
Particle Size1.9 μm
pH2 to 8
Pore Size175 Å
SolventsCompatible with 0 to 100% aqueous and common HPLC solvents
Surface Area220 m²/g
Temperature60°C
Stationary PhaseProprietary
Product LineGlycanPac
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeMixed Mode
PhaseReversed Phase and Ion Exchange
TypeAnalytical Column
TechniqueBio-LC
Unit SizeEach
Mostrando 2 de 2
Exceptional Glycan Selectivity with Industry-Leading Resolution

Ultra-high resolution and selectivity of glycans are attributed to the GlycanPac AXR-1 column's innovative mixed-mode surface chemistry, which combines:

  • WAX functionality for retention of negatively charged glycans, with separation in order of increasing charge
  • Reversed-phase functionality for same-charge glycans, with separation according to isomerism and size
Reliable Column Performance

This high-purity spherical silica column is designed and tested for HPLC and UHPLC methods using either fluorescence or MS detection applications. The GlycanPac AXR-1 column uses volatile aqueous buffers (e.g., ammonium acetate or ammonium formate) and acetonitrile, presenting the eluting glycans ready for introduction into MS instruments.

Available in Multiple Formats
  • Use 1.9 μm columns for UHPLC applications and 3 μm columns for HPLC applications
  • Select from a variety of dimensions to support the resolution, throughput, or instrumental requirements required for your application
  • Protect the analytical column with GycanPac AXR-1 Guard columns
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.