Hydrogen Sulfide - Sulfur Dioxide Analyzer Model 450
Hydrogen Sulfide - Sulfur Dioxide Analyzer Model 450
Thermo Scientific™

Hydrogen Sulfide - Sulfur Dioxide Analyzer Model 450

Measure hydrogen sulfide (H2S) and sulfur dioxide (SO2) in ambient air.
Have Questions?
Número do catálogoDetectable Analytes
450IHydrogen Sulfide, Sulfur Dioxide
Número do catálogo 450I
Preço (BRL)
-
Detectable Analytes:
Hydrogen Sulfide, Sulfur Dioxide

Measure the levels of H2S and SO2 in ambient air with the Thermo Scientific™ Hydrogen Sulfide - Sulfur Dioxide Analyzer Model 450. This analyzer features pulsed fluorescence technology, and performs simultaneous measurement readings to provide reliable data capture on a constant basis.

Discover the iQ to work smarter with our next generation 450iQ Hydrogen Sulfide and Sulfur Dioxide Analyzer.

Key Features:

  • Pulsed excitation and intensity stabilization
  • Reflective bandpass filters
  • Temperature stabilization reaction chamber
  • Stable, long-life UV source
  • Superior zero stability

iSeries Advantage:

  • Ethernet connectivity for efficient remote access
  • Enhanced user interface with one button programming and large display screen
  • Flash memory for increased data storage and user downloadable software
  • Enhanced electronics design optimizes product commonality
  • Improved layout for easier accessibility to components
Especificações
Certifications/ComplianceETL, CSA, UL, CE, UKCA
Depth (English)23 in.
Depth (Metric)584 mm
DescriptionModel 450i Hydrogen Sulfide - Sulfur Dioxide Analyzer
Detection LimitManual Mode SO2 or Combine Sulfur: 2.0 ppb (10 second averaging time); 1.0 ppb (60 second averaging time); 0.5 ppb (300 second averaging time); Automatic Mode SO2 or H2S: 6.0 ppb (10 second averaging time); 2.0 ppb (60 second averaging time); 1.5 ppb (300 seconds)
Height (English)8.62 in.
Height (Metric)219 mm
Measurement RangePreset: 0 to 0.05, 0.1, 0.2, 0.5, 1, 2, 5, and 10 ppm; 0 to 0.2; Extended: 0 to 0.5, 1, 2, 5, 10, 20, 50 and 100 ppm; 0-2, 5, 10, 20, 50, 100, 200, and 250 mg/m3; Custom: 0 to 0.05 to 100 ppm; 0 to 0.2 to 250 mg/m3
Mounting OptionsBench, EIA, retrofit
OutputsSelectable Voltage, RS232/RS485, TCP/IP, 10 Status Relays, and Power Fail Indication (standard); 0 to 20 or 4 to 20mA Isolated Current Outout (optional)
Precision1% of reading or 1 ppb (whichever is greater)
Span Drift±1% full scale
Temperature (English) Operating68°F to 86°F
Voltage100/115/220/240 V
Weight (English)48 lb.
Weight (Metric)21.8 kg
Width (English)16.75 in.
Width (Metric)425 mm
Zero Drift<1ppb
Detectable AnalytesHydrogen Sulfide, Sulfur Dioxide
Inputs16 Digital Inputs (Standard), 8 0 to 10 VDC Analog Inputs (Optional)
Linearity±1% full scale <100 ppm
Response Time80 sec. (10 sec. average time); 110 sec. (60 sec. average time); 320 sec. (300 sec. average time)
Temperature (Metric) Operating20°C to 30°C
Zero NoiseManual Mode SO2 or Combine Sulfur: 1.0 ppb (10 sec. averaging time); 0.5 ppb (60 sec. averaging time); 0.25 ppb (300 sec. averaging time); Automatic Mode SO2 or H2S: 3.0 ppb (10 sec. averaging time); 1.5 ppb (60 sec. averaging time); 0.75 ppb (300 sec. averaging time)
Unit SizeEach