Thermo Scientific™

SOLAμ™ SPE Plates

Número do catálogo: 60209-001
Thermo Scientific™

SOLAμ™ SPE Plates

Número do catálogo: 60209-001
Remove variability and optimize high throughput laboratory workflows. Thermo Scientific™ SOLAμ™ Solid Phase Extraction (SPE) Plates are designed for bioanalytical and clinical research analysts who require cleaner, highly reproducible, and robust sample extraction using very low sample and solvent volumes in high throughput workflows. SOLAμ Well Plates achieve this due to the unique and award winning innovative frit-less SPE technology.
 
Número do catálogo
60209-001
Tamanho da unidade
Each
Description
HRP 2 mg/1 mL 96 well plate
Especificações completas
DescriptionHRP 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Hydrophobic Retention of Neutral Compounds with Complementary Retention of Polar Analytes. An All-Purpose Phase.
Product LineSOLAμ
SorbentHRP (Reversed Phase Polymeric)
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
SCX 2 mg/1 mL 96 well plate
Especificações completas
DescriptionSCX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Weak Basic Compounds. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Strong Cation Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
SAX 2 mg/1 mL 96 well plate
Especificações completas
DescriptionSAX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Weak Acidic Compounds. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Strong Anion Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
WCX 2 mg/1 mL 96 well plate
Especificações completas
DescriptionWCX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Strong Basic Compounds. Sorbent Charge Can be Activated or Deactivated. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Weak Cation Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
WAX 2 mg/1 mL 96 well plate
Especificações completas
DescriptionWAX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Strong Acidic Compounds. Sorbent Charge Can be Activated or Deactivated. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Weak Anion Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
Mostrando 5 de 5
Número do catálogoEspecificaçõesTamanho da unidadeDescriptionPreço (BRL)
60209-001Especificações completas
EachHRP 2 mg/1 mL 96 well plateEntre em contato ›
DescriptionHRP 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Hydrophobic Retention of Neutral Compounds with Complementary Retention of Polar Analytes. An All-Purpose Phase.
Product LineSOLAμ
SorbentHRP (Reversed Phase Polymeric)
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
60209-002Especificações completas
EachSCX 2 mg/1 mL 96 well plateEntre em contato ›
DescriptionSCX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Weak Basic Compounds. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Strong Cation Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
60209-003Especificações completas
EachSAX 2 mg/1 mL 96 well plateEntre em contato ›
DescriptionSAX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Weak Acidic Compounds. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Strong Anion Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
60209-004Especificações completas
EachWCX 2 mg/1 mL 96 well plateEntre em contato ›
DescriptionWCX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Strong Basic Compounds. Sorbent Charge Can be Activated or Deactivated. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Weak Cation Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
60209-005Especificações completas
EachWAX 2 mg/1 mL 96 well plateEntre em contato ›
DescriptionWAX 2 mg/1 mL 96 well plate
Bed Weight2 mg
For Use With (Application)Bioanalytical Applications - Strong Ion-Exchange Retention of Strong Acidic Compounds. Sorbent Charge Can be Activated or Deactivated. Complementary Reversed Phase Retention of Neutral Compounds.
Product LineSOLAμ
SorbentMixed Mode Weak Anion Exchanger, Polymeric
Type96-well SPE Plate
Volume (Metric) Well1 mL
Unit SizeEach
Mostrando 5 de 5
Ideal for Bioanalytical and Clinical Research Laboratories

Bioanalytical laboratories continue to drive to higher efficacy drugs and long acting formulations which require lower quantification limits. There is also the desire to take advantage of the replacement, refinement and reduction policy which is resulting in reduced animal model use. The growth of biopharmaceuticals also brings into consideration additional analytical issues such as solvation and non-specific binding.

Meet Demanding Sample Preparation Requirements
  • Processing of low sample volumes
  • High sensitivity due to low elution volumes
  • High reproducibility
  • Low analytical sample failures
  • Ease of use
  • High throughput processing

SOLAμ is the first micro-elution product to meet the requirements of the bioanalyst in combination with a robust, easy to use format.

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figuras

Documentos e downloads

Certificados

    Perguntas frequentes

    Citações e referências

    Search citations by name, author, journal title or abstract text