Thermo Scientific™

Evolution™ Smart Thermostatted Linear 8-Cell Changer Accessory

Número do catálogo: 840-219500
Thermo Scientific™

Evolution™ Smart Thermostatted Linear 8-Cell Changer Accessory

Número do catálogo: 840-219500
Precisely position up to eight samples with the Thermo Scientific™ Evolution™ Smart Thermostatted Linear 8-Cell Changer Accessory for the Thermo Scientific™ Evolution™ spectrophotometers.  Thermostatting, where required, is accomplished with a flow of water from an external temperature controlled recirculating water bath.
 
Número do catálogo
840-219500
Tamanho da unidade
Each
Description
Temperature Probe
Especificações completas
CompatibilityNot compatible with:,
Smart accessory base temperature probe connector. Choose PN 10011401 for direct connection to a Smart accessory base., VISION software
DescriptionTemperature Probe
Diameter (English)0.040 in.
TypeTemperature Probe
For Use With (Equipment)Temperature Probe Hub, PN 840-214600
Immersion Depth2 mm
IncludesSingle temperature probe equipped with stoppers for cuvettes with either a round opening for a stopper or a standard square opening for a lid
Length (English)1.5 in.
MaterialStainless steel
Thermocouple TypeType T
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
Smart Thermostatted Linear 8-cell Changer
Especificações completas
CalibrationCustom calibration sequence in INSIGHT software for the Evolution One/One Plus spectrophotometers finds the center of each cell aperture and remembers the position, going to that spot precisely each time it measures the cell.
Compatibility10mm pathlength standard volume, <10mm pathlength cells with appropriate spacer
Configuration DetailsSample position only
DescriptionSmart Thermostatted Linear 8-cell Changer
TypeSmart Thermostatted Linear 8-Cell Changer
For Use With (Equipment)Evolution One/One Plus and Evolution Pro Spectrophotometers
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
Temperature Probe Hub and Probe
External hub with sockets for up to 8 temperature probes
Especificações completas
Configuration DetailsConnect the accessory to the computer controlling the spectrophotometer with INSIGHT or the local control head on the spectrophotometer. Temperature readings from all connected probes can be displayed “live” within INSIGHT and recorded with each cell measurement reading.
ConnectionsMiniature thermocouple, 1.8 m USB cable supplied
DescriptionTemperature Probe Hub and Probe
External hub with sockets for up to 8 temperature probes
Dimensions (L x W x H)201 x 104 x 34 mm
TypeTemperature Probe Hub and Probe
For Use With (Equipment)Evolution One/One Plus spectrophotometers with INSIGHT software
IncludesProbe hub, single temperature probe (840-219500) and USB cable for connection to computer running INSIGHT
Required AccessoriesAdditional probes (840-219500) to measure cells beyond the first
Resolution±0.1°C
Temperature Precision>0,2 % ± 0,5 °C
Temperature Range (Metric)-200 to 350°C
Unit SizeEach
Mostrando 3 de 3
Número do catálogoEspecificaçõesTamanho da unidadeDescriptionPreço (BRL)
840-219500Especificações completas
EachTemperature ProbeEntre em contato ›
CompatibilityNot compatible with:,
Smart accessory base temperature probe connector. Choose PN 10011401 for direct connection to a Smart accessory base., VISION software
DescriptionTemperature Probe
Diameter (English)0.040 in.
TypeTemperature Probe
For Use With (Equipment)Temperature Probe Hub, PN 840-214600
Immersion Depth2 mm
IncludesSingle temperature probe equipped with stoppers for cuvettes with either a round opening for a stopper or a standard square opening for a lid
Length (English)1.5 in.
MaterialStainless steel
Thermocouple TypeType T
Unit SizeEach
840-219000Especificações completas
EachSmart Thermostatted Linear 8-cell ChangerEntre em contato ›
CalibrationCustom calibration sequence in INSIGHT software for the Evolution One/One Plus spectrophotometers finds the center of each cell aperture and remembers the position, going to that spot precisely each time it measures the cell.
Compatibility10mm pathlength standard volume, <10mm pathlength cells with appropriate spacer
Configuration DetailsSample position only
DescriptionSmart Thermostatted Linear 8-cell Changer
TypeSmart Thermostatted Linear 8-Cell Changer
For Use With (Equipment)Evolution One/One Plus and Evolution Pro Spectrophotometers
Unit SizeEach
840-214600Especificações completas
EachTemperature Probe Hub and Probe
External hub with sockets for up to 8 temperature probes
Entre em contato ›
Configuration DetailsConnect the accessory to the computer controlling the spectrophotometer with INSIGHT or the local control head on the spectrophotometer. Temperature readings from all connected probes can be displayed “live” within INSIGHT and recorded with each cell measurement reading.
ConnectionsMiniature thermocouple, 1.8 m USB cable supplied
DescriptionTemperature Probe Hub and Probe
External hub with sockets for up to 8 temperature probes
Dimensions (L x W x H)201 x 104 x 34 mm
TypeTemperature Probe Hub and Probe
For Use With (Equipment)Evolution One/One Plus spectrophotometers with INSIGHT software
IncludesProbe hub, single temperature probe (840-219500) and USB cable for connection to computer running INSIGHT
Required AccessoriesAdditional probes (840-219500) to measure cells beyond the first
Resolution±0.1°C
Temperature Precision>0,2 % ± 0,5 °C
Temperature Range (Metric)-200 to 350°C
Unit SizeEach
Mostrando 3 de 3

Make the most of your spectrophotometer’s capabilities:

  • Automate measurement of up to 8 samples
  • Automate measurement of standards for QA/QC measurements
  • Measure multi-cell kinetics reactions


Features:

  • Temperature range: -10° to 100°C
  • Precision cell holder mechanism securely holds up to 8 standard 10mm pathlength cells
  • Automatic recognition and alignment
  • Precision engineered cell transport system offers quiet operation and positioning accuracy
  • Easy connections for circulating liquid temperature control
  • Collection tray and drain catches any leaking samples
  • Full software control with Thermo Scientific™ INSIGHT™ software 


Configurations:

  • Use in sample position of Evolution One/One Plus or Evolution Pro only


Options:

  • Recirculator package for temperature control
  • Appropriate temperature probe(s) for temperature monitoring

 

NOTE: Microcell and semi-microcell applications with this accessory are not recommended

 

Figuras

Documentos e downloads

Certificados

    Perguntas frequentes

    Citações e referências

    Search citations by name, author, journal title or abstract text