Thermo Scientific™

Syncronis™ Silica HPLC Columns

Número do catálogo: 97005-253030
Thermo Scientific™

Syncronis™ Silica HPLC Columns

Número do catálogo: 97005-253030
Optimize the reproducibility of normal phase chromatographic separations using Thermo Scientific™ Syncronis™ Silica LC Columns. Highly pure, base-deactivated, high surface area silica media ensure robust, high-resolution separations of nonpolar and moderately polar organic compounds by normal phase chromatography. Manufactured and rigorously tested in ISO 9000 facilities, these columns are designed to meet a range of analytical needs including fast method development, quantitative analysis and quality control.
 
Número do catálogo
97005-253030
Tamanho da unidade
Each
Particle Size
5 μm
Diameter (Metric)
3 mm
Length (Metric)
250 mm
Especificações completas
Column FormatAnalytical Column
Diameter (Metric)3 mm
Length (Metric)250 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Particle Size
5 μm
Diameter (Metric)
2.1 mm
Length (Metric)
150 mm
Especificações completas
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Length (Metric)150 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Particle Size
5 μm
Diameter (Metric)
4.6 mm
Length (Metric)
150 mm
Especificações completas
Column FormatAnalytical Column
Diameter (Metric)4.6 mm
Length (Metric)150 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Particle Size
1.7 μm
Diameter (Metric)
2.1 mm
Length (Metric)
100 mm
Especificações completas
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
For Use WithHPLC
Length (Metric)100 mm
Max. Pressure18130 psi (1250 bar)
Particle Size1.7 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
Número do catálogo
Tamanho da unidade
Pack of 4
Particle Size
5 μm
Diameter (Metric)
4 mm
Length (Metric)
10 mm
Especificações completas
Column FormatGuard Cartridge, 4 Pk.
Diameter (Metric)4 mm
For Use WithUniguard Direct-Connection and Stand Alone Holder
Length (Metric)10 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialBase-Deactivated Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeGuard Cartridge
Unit SizePack of 4
Mostrando 5 de 5
Número do catálogoEspecificaçõesTamanho da unidadeParticle SizeDiameter (Metric)Length (Metric)Preço (BRL)
97005-253030Especificações completas
Each5 μm3 mm250 mmEntre em contato ›
Column FormatAnalytical Column
Diameter (Metric)3 mm
Length (Metric)250 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
97005-152130Especificações completas
Each5 μm2.1 mm150 mmEntre em contato ›
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Length (Metric)150 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
97005-154630Especificações completas
Each5 μm4.6 mm150 mmEntre em contato ›
Column FormatAnalytical Column
Diameter (Metric)4.6 mm
Length (Metric)150 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
97002-102130Especificações completas
Each1.7 μm2.1 mm100 mmEntre em contato ›
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
For Use WithHPLC
Length (Metric)100 mm
Max. Pressure18130 psi (1250 bar)
Particle Size1.7 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialSpherical, Fully Porous, Ultrapure Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeAnalytical Column
Unit SizeEach
97005-014001Especificações completas
Pack of 45 μm4 mm10 mmEntre em contato ›
Column FormatGuard Cartridge, 4 Pk.
Diameter (Metric)4 mm
For Use WithUniguard Direct-Connection and Stand Alone Holder
Length (Metric)10 mm
Max. Pressure5800 psi (400 bar)
Particle Size5 μm
pH2 to 8
Pore Size100 Å
Surface Area320 m²/g
Temperature60°C
USP TypeL3
Stationary PhaseSilica
Product LineSyncronis
Packing MaterialBase-Deactivated Silica
Column TypeNormal Phase
PhaseNormal Phase
TypeGuard Cartridge
Unit SizePack of 4
Mostrando 5 de 5
Excellent Reproducibility in Normal Phase Chromatography

 

  • Highest quality silica ensure consistent, predictable LC performance
  • Exceptional Column-to-Column Consistency
  • Manufactured, packed and tested in ISO-9000-accredited facilities
  • Every column individually tested to meet stringent retention, efficiency and peak symmetry specifications
  • Enhanced automated packing process

Available in Three Particle Sizes

  • 1.7μm for rapid ultrahigh-performance LC (UHPLC) separations
  • 3μm and 5μm for more traditional HPLC analysis
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figuras

Documentos e downloads

Certificados

    Perguntas frequentes

    Citações e referências

    Search citations by name, author, journal title or abstract text