PXS5-926 MicroFocus 90kV X-Ray Source
PXS5-926 MicroFocus 90kV X-Ray Source
Thermo Scientific™

PXS5-926 MicroFocus 90kV X-Ray Source

The Thermo Scientific™ PXS5-926 is a 90kV microfocus X-Ray source for use in high-resolution imaging applications. The small spot size and high magnification, combined with stable output allow superior quality 2D and 3D images.
Have Questions?
Número do catálogoCone of IlluminationTarget MaterialSpot Size
PXS592645° Round BeamTungsten5 μ @ 4 watts, 60 to 90kV7 μ @ 4 watts, 45 to 60kV9 μ @ 8 watts, 45 to 90kV
Número do catálogo PXS5926
Preço (BRL)
-
Cone of Illumination:
45° Round Beam
Target Material:
Tungsten
Spot Size:
5 μ @ 4 watts, 60 to 90kV7 μ @ 4 watts, 45 to 60kV9 μ @ 8 watts, 45 to 90kV
The Thermo Scientific™ PXS5-926 is a 90kV microfocus X-Ray source for use in high-resolution imaging applications. The small spot size and high magnification, combined with stable output allow superior quality 2D and 3D images.
Thermo Scientific PXS5-926 X-Ray sources offer many attractive benefits:
  • Small, round spot optimized over the range of operating voltage and power for distortion-free images
  • 5 micron spot at 4 watts for highest resolution imaging
  • 8.5mm spot-to-window spacing provides exceptional geometric magnification
  • X-Ray tube, power supply, and control electronics in one compact package make system integration easy

Recommended for:

  • Manual inspection of printed circuit boards and electronic devices
  • Nondestructive test requiring high-resolution imaging of metal and plastic parts
  • Micro-CT imaging for industrial and life sciences applications
Especificações
Control Module DetailsAnalog control and monitoring of operating conditions and status
Description90kV MicroFocus X-Ray Source
Diameter (English) Window46 in.
Diameter (Metric) WindowApproximately 11.7 mm
Humidity Range0 to 95%, up to 5000 feet
Input Power12-14 VDC, 4A
Max. Beam Current0.178mA at 45kV
Max. Power8w (45 to 90kV)
Method of CoolingCooling air must be directed at the unit to maintain the tube mounting plate temperature below 50°C (below 40°C is recommended).
Operating Voltage Range20 to 90kV
Shielding TypeX-Ray leakage behind the X-Ray tube is less than 0.5mR/hour, measured one inch away with Victoreen 190.
Spot Elipticity±10% @ 8 watts, 90kV (either axis referred to average)
Spot Size5 μ @ 4 watts, 60 to 90kV7 μ @ 4 watts, 45 to 60kV9 μ @ 8 watts, 45 to 90kV
Temperature (Metric) Operating0°C to 32°C
Thickness (English) Window0.005 in.
Thickness (Metric) Window0.127 mm
Weight (English)8 lb.
Weight (Metric)3.6 kg
Cone of Illumination45° Round Beam
Power Consumption4 amps
Target MaterialTungsten
Window MaterialBeryllium
Unit SizeEach