Thermo Scientific™ TLD-100 Thermoluminescent Dosimetry Material consists of Lithium Fluoride (Li natural) LiF:Mg, Ti. Suitable for health and medical physics dosimetry applications.

 
Número do catálogo
SNO10111
Tamanho da unidade
Each
Description
TLD-100 Microcube (1 x 1 x 1 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 Microcube (1 x 1 x 1 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)1 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)1 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)1 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 rod (Diameter: 1 x 6 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 rod (Diameter: 1 x 6 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)6 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter1 mm
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 chip (3.2 x 3.2 x 0.15 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (3.2 x 3.2 x 0.15 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.15 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 chip (3.2 x 3.2 x 0.38 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (3.2 x 3.2 x 0.38 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.38 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 chip (3.2 x 3.2 x 0.89 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (3.2 x 3.2 x 0.89 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.89 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 disk (Diameter: 3.6 x 0.25 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 3.6 x 0.25 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.25 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter3.6 mm
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 disk (Diameter: 3.6 x 0.38 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 3.6 x 0.38 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.38 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter3.6 mm
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 disk (Diameter: 4.5 x 0.6 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 4.5 x 0.6 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.6 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter4.5 mm
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 disk (Diameter: 4.5 x 0.89 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 4.5 x 0.89 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.89 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter4.5 mm
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
TLD-100 chip (Pelletized, 3.2 x 3.2 x 0.89 mm)
Especificações completas
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (Pelletized, 3.2 x 3.2 x 0.89 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.89 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
Mostrando 10 de 16Mostrar mais
Número do catálogoEspecificaçõesTamanho da unidadeDescriptionPreço (BRL)
SNO10111Especificações completas
EachTLD-100 Microcube (1 x 1 x 1 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 Microcube (1 x 1 x 1 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)1 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)1 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)1 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
SNO10106Especificações completas
EachTLD-100 rod (Diameter: 1 x 6 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 rod (Diameter: 1 x 6 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)6 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter1 mm
Unit SizeEach
SNO18806Especificações completas
EachTLD-100 chip (3.2 x 3.2 x 0.15 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (3.2 x 3.2 x 0.15 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.15 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
SNO18815Especificações completas
EachTLD-100 chip (3.2 x 3.2 x 0.38 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (3.2 x 3.2 x 0.38 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.38 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
SNO18835Especificações completas
EachTLD-100 chip (3.2 x 3.2 x 0.89 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (3.2 x 3.2 x 0.89 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.89 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
SNP13610Especificações completas
EachTLD-100 disk (Diameter: 3.6 x 0.25 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 3.6 x 0.25 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.25 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter3.6 mm
Unit SizeEach
SNP13615Especificações completas
EachTLD-100 disk (Diameter: 3.6 x 0.38 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 3.6 x 0.38 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.38 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter3.6 mm
Unit SizeEach
SNP14524Especificações completas
EachTLD-100 disk (Diameter: 4.5 x 0.6 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 4.5 x 0.6 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.6 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter4.5 mm
Unit SizeEach
SNP14535Especificações completas
EachTLD-100 disk (Diameter: 4.5 x 0.89 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 disk (Diameter: 4.5 x 0.89 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.89 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Product TypeThermoluminescent Dosimetry Material
Measurement Ranges10 pGy to 10 Gy
Diameter4.5 mm
Unit SizeEach
SNP18835Especificações completas
EachTLD-100 chip (Pelletized, 3.2 x 3.2 x 0.89 mm)Entre em contato ›
Accuracy±15 (±2 sigma) %
DescriptionTLD-100 chip (Pelletized, 3.2 x 3.2 x 0.89 mm)
Emission Spectra3500 to 6000 Å (4000 maximum)
Energy Response1.25 keV/6°Co
Height (Metric)0.89 mm
MaterialLithium Fluoride (Li natural) LiF:Mg. Ti
Sensitivity1.0 at 60Co relative to LiF
Width (Metric)3.2 mm
Product TypeThermoluminescent Dosimetry Material
Length (Metric)3.2 mm
Measurement Ranges10 pGy to 10 Gy
Unit SizeEach
Mostrando 10 de 16Mostrar mais
Single element dosimeters and assemblies are widely used in many installations and processed using Harshaw TLD Systems. These systems include a range of readers and irradiators with compatible software to implement calibration, radiation evaluation and management, dose algorithms, health physics record keeping, finder database, glow curve analysis and chain of custody monitoring.
  • Nearly tissue-equivalent
  • ± 15% sample-to-sample uniformity
  • Repeatability to within 2% or better

Note:

Handling - Vacuum tweezers should always be used. (Avoid mechanical tweezers or fingers). Small scratches, loss of mass or foreign deposits affect light emission).

Annealing - For annealing temperatures up to 400°C, the containers should be made from high temperature stainless steel or oxidized aluminum, preferably thin to assist rapid cooling following annealing. (Do not use non-oxidized aluminum). The use of a dedicated annealing oven reduces the risk of contamination by foreign material. Place the annealing containers on open oven racks with air space all round to avoid inconsistent heat gradients. (Do not stack containers or allow them to touch the oven walls).

Figuras