Thermo Scientific™

Vanquish™ Split Samplers

Número do catálogo: VC-A13-A-02
Thermo Scientific™

Vanquish™ Split Samplers

Número do catálogo: VC-A13-A-02

Combine excellent injection precision with huge sample capacity with Thermo Scientific™ Vanquish™ Split Samplers. These samplers employ high-throughput performance to deliver the highest possible confidence in peak identification and quantitation. They provide unsurpassed sample dosing precision and are optimized for ruggedness and uptime, even under system pressures of up to 1500 bar (22,000 psi) and challenging eluent conditions. Now you can record UHPLC data over several days unattended, without running out of samples.


View HPLC/UHPLC resources

 
Número do catálogo
VC-A13-A-02
Tamanho da unidade
Each
Description
Vanquish™ Split Sampler C
Biocompatible Version
No
Especificações completas
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 3 μL (caffeine in water); Typically <0.5% area RSD for 1 μL (caffeine in water)
Injection TypeSplit Loop
Biocompatible VersionNo
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
DescriptionVanquish™ Split Sampler C
Carryover<0.002% with caffeine
Temperature RangeSample compartment: not available
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
Vanquish Split Sampler HT
Biocompatible Version
Yes
Especificações completas
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 1 μL (caffeine in water); Typically <0.5% area RSD for 0.5 μL (caffeine in water)
Injection Volume Range0.01 to 25 μL, min. step 0.01 μL; Optional: 0.01 to 100 μL
Injection TypeSplit Loop
Biocompatible VersionYes
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
DescriptionVanquish Split Sampler HT
Carryover<0.002% with caffeine
Temperature RangeSample compartment: 4°C to 40°C
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
Vanquish™ Split Sampler CT
Biocompatible Version
No
Especificações completas
TypeSplit Sampler CT
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 3 μL (caffeine in water); Typically <0.5% area RSD for 1 μL (caffeine in water)
Injection TypeSplit Loop
Sample Capacity216 Samples
Max. Pressure1500 bar
Biocompatible VersionNo
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
DescriptionVanquish™ Split Sampler CT
Carryover<0.002% with caffeine
Temperature RangeSample compartment: 4°C to 40°C
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
Número do catálogo
Tamanho da unidade
Each
Description
Vanquish Split Sampler FT
Biocompatible Version
Yes
Especificações completas
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 1 μL (caffeine in water); Typically <0.5% area RSD for 0.5 μL (caffeine in water)
Injection Volume Range0.01 to 25 μL, min. step 0.01 μL; Optional: 0.01 to 100 μL
Injection TypeSplit Loop
Biocompatible VersionYes
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
DescriptionVanquish Split Sampler FT
Carryover<0.002% with caffeine
Temperature RangeSample compartment: 4°C to 40°C
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
Mostrando 4 de 4
Número do catálogoEspecificaçõesTamanho da unidadeDescriptionBiocompatible VersionPreço (BRL)
VC-A13-A-02Especificações completas
EachVanquish™ Split Sampler CNoRequisite uma Cotação
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 3 μL (caffeine in water); Typically <0.5% area RSD for 1 μL (caffeine in water)
Injection TypeSplit Loop
Biocompatible VersionNo
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
DescriptionVanquish™ Split Sampler C
Carryover<0.002% with caffeine
Temperature RangeSample compartment: not available
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
VH-A10-A-02Especificações completas
EachVanquish Split Sampler HTYesRequisite uma Cotação
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 1 μL (caffeine in water); Typically <0.5% area RSD for 0.5 μL (caffeine in water)
Injection Volume Range0.01 to 25 μL, min. step 0.01 μL; Optional: 0.01 to 100 μL
Injection TypeSplit Loop
Biocompatible VersionYes
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
DescriptionVanquish Split Sampler HT
Carryover<0.002% with caffeine
Temperature RangeSample compartment: 4°C to 40°C
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
VC-A12-A-02Especificações completas
EachVanquish™ Split Sampler CTNoRequisite uma Cotação
TypeSplit Sampler CT
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 3 μL (caffeine in water); Typically <0.5% area RSD for 1 μL (caffeine in water)
Injection TypeSplit Loop
Sample Capacity216 Samples
Max. Pressure1500 bar
Biocompatible VersionNo
PC ConnectionUSB 2.0; 3-port HUB to connect additional Vanquish modules
DescriptionVanquish™ Split Sampler CT
Carryover<0.002% with caffeine
Temperature RangeSample compartment: 4°C to 40°C
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
VF-A10-A-02Especificações completas
EachVanquish Split Sampler FTYesRequisite uma Cotação
Injection Cycle TimeDown to 8 sec. depending on separation conditions
Injection Volume Precision<0.25% area RSD for 1 μL (caffeine in water); Typically <0.5% area RSD for 0.5 μL (caffeine in water)
Injection Volume Range0.01 to 25 μL, min. step 0.01 μL; Optional: 0.01 to 100 μL
Injection TypeSplit Loop
Biocompatible VersionYes
PC ConnectionUSB 2.0; 3-port-HUB to connect further Vanquish modules
DescriptionVanquish Split Sampler FT
Carryover<0.002% with caffeine
Temperature RangeSample compartment: 4°C to 40°C
Dimensions (L x W x H)290 mm x 420 mm x 620 mm (11.4 in. x 16.5 in. x 24.4 in.)
Unit SizeEach
Mostrando 4 de 4
Maximum injection precision, huge sample capacity, high-throughput performance
  • SmartInject technology for unrivaled retention time precision and extended column lifetime up to max. 1500bar (22,000psi)
  • Out-of-the-box vial capacity of 216 samples
  • Increase sample capacity to 23 well plates (up to 8832 samples) by adding the optional Thermo Scientific™ Vanquish™ Charger module
  • By default, all thermostatted Vanquish Samplers utilize air stream cooling to maintain sample integrity
  • Automated sample configuration using barcode reading
  • Transfer of methods is incredibly easy
  • Unlimited application flexibility with customizable gradient delay volume
Ordering Information

Sample capacity: Any four of the following (SBS footprint)

  • 54 x 12 mm OD vials (≤1.5 mL)
  • 96 x 6, 7 and 8 mm OD vials (≤1.2 mL)
  • 16 x 15 mm OD vials (≤4 mL)
  • 9 x 22.5 mm OD vials (≤10 mL)
  • Well plates (96 and 384, deep and shallow)
+ capacity of 12 x 22.5 mm OD vials (≤10 mL) in the carousel

Figuras

Documentos e downloads

Certificados

    Perguntas frequentes

    Citações e referências

    Search citations by name, author, journal title or abstract text