Nuclear facilities need accurate, reliable, sustained early warning of radiation leaks. The Thermo Scientific™ FHT 6020 Area Monitor Display and Alarms offers maximum reliability for permanent operation within nuclear facilities or environmental networks with up to 16 measurement channels that can process and display data from Thermo Scientific intelligent dose rate probes, FH 40 G series probes as well as analog or digital input. All channels can be operated simultaneously, along with audible and visible alarms, to measure and assess the level of gamma and neutron radiation.

 
Catalog Number
HSA32400US
Unit Size
Each
Description
Stand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUT
Price (CLP)
Full specifications
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUT
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
US alarm unit set (Comprising FHT 6025N)
Price (CLP)
Full specifications
DescriptionUS alarm unit set (Comprising FHT 6025N)
Height (English)16.3 in.
Height (Metric)415 mm
Depth (English)3 in.
Depth (Metric)7.6 cm
Weight (English)3.1 lb.
Weight (Metric)1.4 kg
Width (English)5.1 in.
Width (Metric)130 mm
HousingAluminum
IncludesConnection cable to FHT 6020
Storage Temperature (English)-4°F to +158°F
Storage Temperature (Metric)-20°C to +70°C
Product TypeRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Network unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cable
Price (CLP)
Full specifications
DescriptionNetwork unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cable
Weight (English)2.8 lb.
Weight (Metric)1.3 kg
HousingAluminum
Storage Temperature (English)-4°F to +158°F
Storage Temperature (Metric)-20°C to +70°C
Product TypeRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cable
Price (CLP)
Full specifications
DescriptionVehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cable
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Stand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Price (CLP)
Full specifications
DescriptionStand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Network unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Price (CLP)
Full specifications
DescriptionNetwork unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Stand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Price (CLP)
Full specifications
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Vehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cable
Price (CLP)
Full specifications
DescriptionVehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cable
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Network unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Price (CLP)
Full specifications
DescriptionNetwork unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Product TypeRadiation Detection Alarm
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Stand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filter
Price (CLP)
Full specifications
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filter
Product TypeRadiation Detection Alarm
Unit SizeEach
Showing 10 of 17Show more
Catalog NumberSpecificationsUnit SizeDescriptionPrice (CLP)
HSA32400USFull specifications
EachStand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUTContact Us ›
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; No analog IN/OUT
Product TypeRadiation Detection Alarm
Unit SizeEach
4255909Full specifications
EachUS alarm unit set (Comprising FHT 6025N)Contact Us ›
DescriptionUS alarm unit set (Comprising FHT 6025N)
Height (English)16.3 in.
Height (Metric)415 mm
Depth (English)3 in.
Depth (Metric)7.6 cm
Weight (English)3.1 lb.
Weight (Metric)1.4 kg
Width (English)5.1 in.
Width (Metric)130 mm
HousingAluminum
IncludesConnection cable to FHT 6020
Storage Temperature (English)-4°F to +158°F
Storage Temperature (Metric)-20°C to +70°C
Product TypeRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
HSD-3-2-4-0-0Full specifications
EachNetwork unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cableContact Us ›
DescriptionNetwork unit; Powered by FHT 6025N alarm unit; 2 ports for FH40G probes; RS232 PC port; No analog IN/OUT; No connection cable
Weight (English)2.8 lb.
Weight (Metric)1.3 kg
HousingAluminum
Storage Temperature (English)-4°F to +158°F
Storage Temperature (Metric)-20°C to +70°C
Product TypeRadiation Detection Alarm
Operating Limit Temperature Range (English)32°F to 12°F
Operating Limit Temperature Range (Metric)0°C to 50°C
Unit SizeEach
HSD32423Full specifications
EachVehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cableContact Us ›
DescriptionVehicle unit; No ports for FH40G probes; RS485 PC port; 2/2 analog IN/OUT; Open cable
Product TypeRadiation Detection Alarm
Unit SizeEach
HSA34423USFull specifications
EachStand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapterContact Us ›
DescriptionStand alone unit; RS485 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Product TypeRadiation Detection Alarm
Unit SizeEach
HSA04400USFull specifications
EachNetwork unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cableContact Us ›
DescriptionNetwork unit; AC adapter; No ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Product TypeRadiation Detection Alarm
Unit SizeEach
HSA32423USFull specifications
EachStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapterContact Us ›
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; integrated AC power adapter
Product TypeRadiation Detection Alarm
Unit SizeEach
HSF32400Full specifications
EachVehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cableContact Us ›
DescriptionVehicle unit; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Open cable
Product TypeRadiation Detection Alarm
Unit SizeEach
HSA34400USFull specifications
EachNetwork unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cableContact Us ›
DescriptionNetwork unit; AC adapter; 2 ports for FH40G probes; RS485 PC port; No analog IN/OUT; Mains cable
Product TypeRadiation Detection Alarm
Unit SizeEach
HSF32423Full specifications
EachStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filterContact Us ›
DescriptionStand alone unit; RS232 PC port; 2 ports for FH40G; 2/2 analog IN/OUT; connection for external DC incl. DC filter
Product TypeRadiation Detection Alarm
Unit SizeEach
Showing 10 of 17Show more

The FHT 6020 Area Monitor Display is an industry-proven configurable area monitor capable of stand-alone or network operation.

Measurement Channels

  • Total number of measurement channels: 16
  • Maximum number of FH40G probe channels: 2
  • Maximum number of analog input channels: 2
  • Maximum number of digital input channels: 4

Measurement History

  • Ring buffer storage for > 1000 data entries
  • Measurement memory for probes of the FH40G range

PC/Network Interface (selectable at order)

  • Connection to a local PC or communication adapters (e.a serial to TCP/IP) via RS-232 interface
  • Incorporation in measuring networks via RS 485 interface

Power Supply Options (selectable at order)

  • External DC supply (typ. 24V)
  • International wide range AC
  • Car supply via special DC filter (9V)

Output Channels

  • Maximum number of analog output channels: 2
  • Maximum number of digital output channels: 5

Firmware

  • Equipped with a flash EEPROM storing the firmware, allowing updates
  • Customer-specific programs possible on request

Software

  • Easily and conveniently configured with a PC via serial interface, and through the configuration program FHT 6020.exe.
  • Networking of multiple units and further measurement equipment via Thermo Scientific™ NETVIEW or Thermo Scientific ™VIEWPOINT Software Packages

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text