Megaplex™ Primer Pools, Rodent Pools Set v3.0
Product Image
Applied Biosystems™

Megaplex™ Primer Pools, Rodent Pools Set v3.0

Los grupos de cebadores Megaplex™ v3.0 está disponible con un solo número de pieza que contiene los cebadores Megaplex™ RTMás información
Have Questions?
Número de catálogoCantidad
444476650 reacciones
Número de catálogo 4444766
Precio (CLP)
1.613.453
Each
Añadir al carro de la compra
Cantidad:
50 reacciones
Precio (CLP)
1.613.453
Each
Añadir al carro de la compra
Los grupos de cebadores Megaplex™ v3.0 está disponible con un solo número de pieza que contiene los cebadores Megaplex™ RT y los cebadores Megaplex™ PreAmp, conjuntos de grupos de roedores.Cebadores Megaplex™ RT, grupo de roedores que contiene de forma colectiva cebadores RT para 641 y 373 microARN únicos para ratón y rata, respectivamente, además de controles específicos de 4 especies.Para su uso cuando la sensibilidad del ensayo es de la máxima importancia, los cebadores Megaplex™ PreAmp mejoran significativamente la capacidad de detectar microARN de baja expresión, lo que permite generar un perfil de expresión completo utilizando mucha menos muestra, tan solo 1 ng del ARN total de entrada.Los grupos de cebadores Megaplex™ están diseñados para usarse con el conjunto de matrices de microARN de roedores v3.0 TaqMan®, sin embargo, también puede usarse para preparar el ADNc para análisis en tiempo real utilizando los ensayos individuales de microARN TaqMan®.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
N.º de reacciones50 reacciones
CebadorCebadores RT, cebadores PreAmp
Línea de productosMegaplex, TaqMan
Tipo de productoGrupo de primers
Cantidad50 reacciones
EspecieRata, ratón
Suficiente para50 reacciones
Para utilizar con (aplicación)Análisis de miARN
GC-Rich PCR PerformanceBajo
Método de PCRqPCR
Unit SizeEach
Contenido y almacenamiento
Almacenar a -20°C

Preguntas frecuentes

Can Ct's greater than a cut-off be considered valid results?

Yes they can. However, it is important to recognize the true linearity and detection limits of your assay: Ct values above the cut-off can indicate non-specific amplification, unless your NTC is a true- no-target control, and you have run a statistically significant number of replicates. Any results with Ct above the recommended cut-off need to be validated with individual assays on plates.

What is a good Ct cut-off for the TaqMan MicroRNA Array Cards and TaqMan Advanced miRNA Array Cards? In other words, beyond what Ct should I not trust the data?

The typical Ct cut-off on TaqMan Array Cards is 32, which is equivalent to Ct 35 on a plate (10 µl reaction). Previous studies show that if you use pre-amplification, a Ct cut-off of 29 or 30 can be used to reduce numbers of false positives (see Technical Note Optimized protocols for human or rodent microRNA profiling with precious samples). To ensure that you have selected a correct cut-off, you should run replicates of the same sample and use Ct cut-off before you see an increase in the Standard Deviation.

Why is water condensing on the reaction wells of the optical side of my TaqMan Array Card?

Most likely the card was not at room temperature before being removed from the packaging. Remove condensation on the reaction wells by lightly blowing room temperature pressurized nitrogen or using an air blower on the wells.
IMPORTANT: Ensure that all water condensation is removed. The optical side of the card must be free of water condensation

Why does the negative control well show amplification when doing microRNA analysis using Megaplex Primer Pools and TaqMan Array Cards?

Most likely the reagents or the cDNA template are contaminated. Please follow established PCR laboratory best practices.

Why do I have poor reproducibility across technical replicates when doing microRNA analysis using Megaplex Primer Pools and TaqMan Array Cards?

Most likely the reagents were not adequately mixed. Ensure that all samples and reagents are mixed well.