Thermo Scientific™

Placas no estériles transparentes de 96 pocillos con fondo redondo para inmunoanálisis, MaxiSorp

Realice ensayos colorimétricos con resultados fiables y reproducibles mediante estas placas transparentes de 96 pocillos no estériles de fondo redondo y para inmunoensayos, que se ofrecen con una selección de superficies para una unión óptima.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoTratamiento de superficie
449824MaxiSorp
3555TS
también denominado 3555
Immulon 1 B
3655TS
también denominado 3655
Immulon 2 HB
475434PolySorp
Número de catálogo 449824
Precio (CLP)
-
Tratamiento de superficie:
MaxiSorp

Realice ensayos colorimétricos con resultados fiables y reproducibles con las placas Thermo Scientific™ de 96 pocillos no estériles de fondo redondo para inmunoensayos, que se ofrecen con una selección de superficies para una unión óptima. Ofrece placas transparentes Thermo Scientific™ Nunc™, Immulon™ y Microtiter™ ideales para inmunoensayos de fase sólida cuantitativos y cualitativos.

Placas sólidas de 96 pocillos:

  • Poliestireno transparente
  • Varias opciones de superficie para conseguir una unión óptima
  • Filas y columnas etiquetadas alfanuméricamente

Superficies:

  • Thermo Scientific PolySorp e Immulon 1B para la adsorción de moléculas hidrófobas.
  • Thermo Scientific Immulon 2HB es ligeramente hidrófilo y se une a una gran variedad de biomoléculas.
  • Thermo Scientific MaxiSorp es hidrófilo e ideal para ensayos de tipo sándwich de anticuerpos.

Información para pedidos:

Tenga en cuenta que la disponibilidad puede variar según el país.

Especificaciones
Propiedad de uniónHidrófilo
Método de detecciónColorimétrico
N.º por caja60
N.° por paquete5
Envase60 cajas
Bloqueo de placasNinguno
Tipo de productoMicroplaca
Molécula dianaAnticuerpos (glucoproteínas)
Volumen de trabajo (métrico)250 μl
matriz, red, conjunto8 x 12
Código de barrasSin código de barras
ColorTransparente
FormatoEstándar
MaterialPoliestireno
N.° de pocillos96
EsterilidadNo estéril
Tratamiento de superficieMaxiSorp
Volumen del pocillo (métrico)300 μl
Forma del pocilloRedondo
Unit SizeCase of 60

Preguntas frecuentes

For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.