Conjugados de anexina V para la detección de apoptosis
Conjugados de anexina V para la detección de apoptosis
Invitrogen™

Conjugados de anexina V para la detección de apoptosis

Detecte las primeras etapas de la apoptosis con la anexina V independiente Alexa Fluor, APC, Pacific Blue, PE, FITC y conjugados de biotina mediante citometría de flujo.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoExcitación/emisiónLíneas láser del citómetro de flujoConjugado
A13199494/518488FITC
A13201495/519488Alexa Fluor 488
A13202578/603532, 561Alexa Fluor 568
A13203590/617532Alexa Fluor 594
A13204Biotina X
A23202346/442UVAlexa Fluor 350
A23204650/665633-637Alexa Fluor 647
A35108555/565532, 561Alexa Fluor 555
A35109679/702633-637Alexa Fluor 680
A35110650/660633-637APC (Aloficocianina)
A35111565/578488, 532, 561PE
A35122410/455405Pacific Blue
Número de catálogo A13199
Precio (CLP)
403.961
Each
Añadir al carro de la compra
Excitación/emisión:
494/518
Líneas láser del citómetro de flujo:
488
Conjugado:
FITC
Precio (CLP)
403.961
Each
Añadir al carro de la compra
Consiga una detección rápida y fiable de la apoptosis celular temprana con conjugados independientes de anexina V para la detección de apoptosis. Los conjugados de anexina V ofrecen una diferencia de hasta 100 veces en la intensidad de la señal de fluorescencia entre células apoptóticas y no apoptóticas mediante citometría de flujo.
La anexina V tiene una alta afinidad a la fosfatidilserina (PS), que se expone en el recubrimiento externo de las células que experimentan apoptosis. Debido a esta afinidad, los reactivos de anexina V etiquetados fluorescentemente se utilizan comúnmente en la investigación de la apoptosis.

Los conjugados de anexina V proporcionan métodos de detección rápidos y fiables para estudiar la externalización de la fosfatidilserina, un indicador de las etapas intermedias de la apoptosis. La diferencia en la intensidad de la fluorescencia entre las células apoptóticas y no apoptóticas teñidas con nuestros conjugados de anexina V fluorescente, medida por citometría de flujo, suele ser de aproximadamente 100 veces.

En colaboración con Nexins Research BV, proporcionamos los mejores y más brillantes conjugados de anexina V disponibles, incluidos los conjugados de anexina V Alexa Fluor 350, 488, 555, 568, 594, 647 y 680, así como los conjugados de anexina V APC, biotina-X, FITC, Pacific Blue y PE. Los conjugados de anexina V altamente fluorescente proporcionan métodos de detección rápidos y fiables para el estudio de la externalización de la fosfatidilserina, uno de los primeros indicadores de apoptosis.

El conjugado de anexina V Pacific Blue es excitable con violeta, lo que lo hace ideal para instrumentos con un láser violeta y para experimentos multicolor que incluyan colorantes verdes o rojos fluorescentes.

Los beneficios de nuestros conjugados de anexina V incluyen:
• Conjugado con los colorantes Invitrogen Alexa Fluor y eFluor para señales más brillantes
• Conjugado para todos los láseres disponibles
• Disponible como reactivos independientes o kits fáciles de usar

La tinción de anexina V para detectar células apoptóticas solo se puede realizar en células y tejidos vivos. Si las muestras se van a fijar después de la tinción, se requieren condiciones específicas para lograr la retención transitoria de la señal. Estas incluyen el uso de un método de fijación a base de aldehídos sin alcohol, el uso de tampones que contengan Ca2+ y evitar los tensioactivos/detergentes. Para su comodidad, también ofrecemos un tampón concentrado de unión a anexina que facilita la unión de la anexina V a la fosfatidilserina en ensayos de apoptosis.

For Research Use Only. Not for use in diagnostic procedures.
Especificaciones
ColorVerde
DescripciónAnexina V, conjugado FITC (sustituye a AnnexinV01, AnnexinV013, PHN1010, PHN1008)
Excitación/emisión494/518
Líneas láser del citómetro de flujo488
Para utilizar con (equipo)Citómetro de flujo
Contenido del kitContiene un vial de anexina V, conjugado FITC .
N.º de reacciones100
Tipo de productoConjugado de anexina V
Cantidad500 μL
Condiciones de envíoHielo húmedo
ConjugadoFITC
Unit SizeEach
Contenido y almacenamiento
Almacenar en el refrigerador (2 °C a 8 °C) y proteger de la luz.

Preguntas frecuentes

I want to study apoptosis using an Annexin V conjugate, but with adherent cells via microscopy instead of flow cytometry. Can this be done?

It has been done, but we don‘t recommend it. Both healthy cells and apoptotic cells possess phosphatidylserine on the cell surface, which can be detected with Annexin V, but apoptotic cells have significantly more of it. You can easily tell the difference between these two populations with flow cytometry, because flow cytometers are more sensitive and have a higher throughput. But with a microscope, you cannot always tell the difference, especially for adherent cells. Instead, for microscopy, we recommend a different technique, such as detecting caspases with CellEvent Caspase Detection Reagents.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I trypsinized my adherent cells and labeled with annexin V, and now my flow data is showing a high percentage of apoptotic cells even for control, untreated cells. What is the problem?

Trypsinization or mechanical scraping of cells temporarily disrupts the plasma membrane, allowing annexin V to bind phosphatidylserine on the cytoplasmic surface of the cell membrane and thus leading to false positive staining. Allow the cells to recover for about 30 minutes in optimal cell culture conditions and medium after trypsinizing/scraping so that they can recover their membrane integrity before staining. For lightly adherent cell lines, such as HeLa and NIH 3T3, another option is to use non-enzyme treatments like Gibco Cell Dissociation Buffer (Cat. No. 13151014).

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Can I detect annexin V staining in an imaging assay?

Annexin V staining is not typically used in imaging experiments; it is a better reagent for flow cytometry analysis. All cells will stain to some extent, so it can be difficult to distinguish a relatively bright annexin V-stained cell from a dimmer non-apoptotic cell. Caspase activation, detected using our CellEvent Caspase 3/7 or Image-iT LIVE Caspase detection kits, is a better method for detecting apoptosis in an imaging assay.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

When should I stain adherent cells with annexin V for flow cytometric analysis? Before or after I trypsinize them?

Trypsinize first and then allow the cells to recover about 30 minutes in optimal cell culture conditions and medium before staining with annexin V conjugates. Trypsinization or mechanical scraping of cells temporarily disrupts the plasma membrane, allowing for annexin V to bind phosphatidylserine on the cytoplasmic surface of the cell membrane and thus leading to false positive staining. For lightly adherent cell lines such as HeLa and NIH 3T3, you could use a less harsh (non-enzymatic) dissociation product like Gibco Cell Dissociation Buffer (Cat. No. 13151014).

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Can I fix my cells after annexin V staining?

Yes, this is possible. We have established protocols for annexin V staining combined with intracellular staining of lymphocytes that can be found here. The most important step is to leave some binding buffer in the suspension when fixation is started. Compared to staining of live cells, the intensity of the annexin V signal may be somewhat reduced.

Citations & References (296)

Citations & References
Abstract
The p42/p44 MAP kinase pathway prevents apoptosis induced by anchorage and serum removal.
Authors:Le Gall M,Chambard JC,Breittmayer JP,Grall D,Pouysségur J,Van Obberghen-Schilling E
Journal:Molecular biology of the cell
PubMed ID:10712523
Anchorage removal like growth factor removal induces apoptosis. In the present study we have characterized signaling pathways that can prevent this cell death using a highly growth factor– and anchorage-dependent line of lung fibroblasts (CCL39). After anchorage removal from exponentially growing cells, annexin V-FITC labeling can be detected after 8 ... More
Authors:
Journal:
PubMed ID:18258751
Authors:
Journal:
PubMed ID:10891486
Strategies for phenotyping apoptotic peripheral human lymphocytes comparing ISNT, annexin-V and 7-AAD cytofluorometric staining methods.
Authors:Lecoeur H,Ledru E,Prévost MC,Gougeon ML
Journal:Journal of immunological methods
PubMed ID:9461328
The present article compares the reliability of four previously described cytofluorometric methods of apoptosis quantification for phenotyping apoptotic human lymphocytes. Each of these assays detects distinct cellular alterations of the apoptotic process. Alteration in plasma membrane integrity can be evaluated following 7-AAD incorporation and the translocation of phosphatidylserine from the ... More
Analysis of ethanol effects on corneal epithelium.
Authors:Oh JY, Yu JM, Ko JH,
Journal:Invest Ophthalmol Vis Sci
PubMed ID:23674759
Ethanol is widely used in ocular surface surgeries and for the treatment of corneal diseases. However, ethanol is a toxic agent that is related to the development of a number of alcohol-related diseases. Despite the common use of ethanol for therapeutic purposes in ophthalmology, effects of ethanol on the ocular ... More