ProcartaPlex™ Human Th1/Th2 Cytokine Panel, 11plex
ProcartaPlex™ Human Th1/Th2 Cytokine Panel, 11plex
Invitrogen™

ProcartaPlex™ Human Th1/Th2 Cytokine Panel, 11plex

El panel ProcartaPlex 11-Plex de citocina Th1/Th2 humana permite el estudio de la respuesta Th1/Th2 mediante el análisis de 11Más información
Have Questions?
Número de catálogoCantidad
EPX110-10810-90196 pruebas
Número de catálogo EPX110-10810-901
Precio (CLP)
3.485.853
Each
Añadir al carro de la compra
Cantidad:
96 pruebas
Precio (CLP)
3.485.853
Each
Añadir al carro de la compra
El panel ProcartaPlex 11-Plex de citocina Th1/Th2 humana permite el estudio de la respuesta Th1/Th2 mediante el análisis de 11 proteínas diana en un solo pocillo a través de la tecnología Luminex xMAP. Este panel es un módulo del panel 1 ProcartaPlex 45-Plex de citocina/quimiocina/factor de crecimiento (n.º de ref. EPX450-12171-901). Este kit es totalmente combinable con los otros módulos o ensayos individuales simples correspondientes a los objetivos del panel de 45 plex.

Los paneles preconfigurados ProcartaPlex se han probado exhaustivamente para determinar la capacidad combinatoria, la interferencia y la reactividad cruzada de los analitos con el fin de proporcionar el mayor nivel de validación y precisión. Todos los paneles ProcartaPlex se suministran con los reactivos necesarios para realizar el ensayo.

Los paneles multiplex ProcartaPlex están disponibles en múltiples formatos en seis especies (humano, ratón, rata, primate no humano, porcino y canino). Visite nuestra página de inmunoensayos ProcartaPlex para obtener más información y consultar los productos disponibles.

Lista de objetivos [región de gránulos]: GM-CSF [44], IFN gamma [43], IL-1 beta [18], IL-2 [19], IL-4 [20], IL-5 [21], IL-6 [25], IL-12p70 [34], IL-13 [35], IL-18 [66], TNF alfa [45]

Acerca de los ensayos ProcartaPlex para la plataforma Luminex
Los inmunoensayos ProcartaPlex se basan en los principios de un ELISA tipo sándwich y utilizan dos anticuerpos altamente específicos que se enlazan a los diferentes epítopos de una proteína para cuantificar todas las proteínas diana simultáneamente mediante un instrumento Luminex. Para los ensayos multiplex ProcartaPlex se requieren tan solo 25 µl de plasma o suero, o 50 µl de sobrenadante del cultivo celular, y solo se necesitan cuatro horas para obtener los resultados analizados.

Las características incluyen:
• Resultados reproducibles y fiables: validados como panel según el estándar más alto del sector, incluidas las pruebas de combinación de proteínas diana y reactividad cruzada
• Más resultados por muestra: permite medir múltiples proteínas diana simultáneamente en una única muestra de 25–50 µL
• Tecnología Luminex consolidada: plataforma de multiplexing de referencia para detección y cuantificación de proteínas

Los ensayos ProcartaPlex utilizan la tecnología Luminex xMAP (método multianálito) para la detección y cuantificación simultáneas de hasta 65 proteínas diana en una única muestra de 25–50 µL de plasma, suero, sobrenadantes del cultivo celular y otros fluidos corporales.

Las microesferas de Luminex del ensayo de ProcartaPlex se tiñen internamente con proporciones precisas de fluoróforos rojos e infrarrojos para crear firmas específicas que pueden ser identificadas por los sistemas de detección Luminex xMAP (por ejemplo, Luminex 200, FLEXMAP 3D y MAGPIX). El ensayo ProcartaPlex, similar a un ELISA tipo sándwich, utiliza pares de anticuerpos emparejados para identificar la proteína de interés. En un ensayo multiplex, cada gránulo espectralmente único se etiqueta con anticuerpos específicos para una sola proteína diana, y las proteínas vinculadas se identifican con anticuerpos biotinilados y estreptavidina-R-ficoeritrina (RPE). La conjugación de anticuerpos específicos de proteínas en un gránulo distinto permite el análisis de varios elementos diana en un solo pocillo.

La diferencia más significativa entre un ensayo ProcartaPlex y uno ELISA es que el anticuerpo de captura del ensayo ProcartaPlex se conjuga en un gránulo y no se adsorbe en el pocillo de la microplaca, por lo que los reactivos del ensayo ProcartaPlex flotan en la solución. Para la detección, el instrumento Luminex 200, por ejemplo, contiene dos láseres, uno para distinguir la firma espectral de cada partícula y el segundo para cuantificar la cantidad de fluorescencia RPE, que es proporcional a la cantidad de proteína presente en la muestra. Los ensayos multiplex ProcartaPlex pueden determinar el perfil de más proteínas diana con mucha menos muestra en el mismo tiempo que se tarda en realizar un ELISA tipo sándwich tradicional.

Los paneles multiplex ProcartaPlex están disponibles en múltiples formatos en seis especies (humano, ratón, rata, primate no humano, porcino y canino). Visite thermofisher.com/procartaplex para obtener más información y consultar los productos disponibles.

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Intervalo del ensayoVer certificado de análisis
Sensibilidad del ensayoMenos del 15 %
Para utilizar con (equipo)Instrumentos Luminex™
FormatoKit multiplex
Línea de productosProcartaPlex
Tipo de muestraSobrenadantes de cultivo celular, suero y plasma, Plasma, Cell Culture Supernatants
Volumen de muestraSuero, plasma: 25 μl; CCS: 50 μl
Condiciones de envíoHielo húmedo
CombinabilityCombinable
Tipo de productoPanel
Cantidad96 pruebas
Research AreaImmunology, Cytokines
EspecieHumano
Unit SizeEach
Contenido y almacenamiento
  • 2 viales de mezcla estándar humana A (liofilizada)
  • 1 vial de mezcla de gránulos de captura (1X)
  • 1 vial de mezcla de anticuerpos de detección biotinilada (50X)
  • 1 frasco de tampón de lectura (1X)
  • 1 frasco de tampón de lavado (10x)
  • 1 frasco de estreptavidina-PE (1X)
  • 1 frasco de tampón de ensayo universal (1 X)
  • 1 frasco de diluyente de anticuerpos de detección (1X)
  • Tira de 8 tubos
  • Película adhesiva
  • Placa de 96 pocillos de fondo plano, negra
  • Almacenar entre 2 °C y 8 °C

Preguntas frecuentes

What is the size of the Luminex beads you currently use?

The beads used in our Luminex instrument-compatible ProcartaPlex and QuantiGene Plex assays are 6.5 micron superparamagnetic beads.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

I am interested in performing Luminex assays using BioSource kits, and I have a Luminex xMAP system. Besides the kits and system, what other reagents and equipment will I need?

The following is a list of general lab supplies that are required for running BioSource immunoassays on the Luminex xMAP system:
1) Sonicating water bath
2) Orbital shaker
3) Vortexer
4) Repeating and/or multi-channel pipetter (not required, but recommended)
5) Calibrated adjustable precision pipettes, with disposable plastic tips
6) Glass/plastic tubes and racks for preparing reagents
7) Graduated cylinder and container for preparing wash solution
8) Aluminum foil
9) Deionized or distilled water.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Do the Luminex beads require special care in handling?

The Luminex beads should be protected from light because they are susceptible to photobleaching. We recommend protecting the beads by keeping containers covered with aluminum foil during all incubation steps, and exercising care during handling. The beads should not be frozen, subjected to excessive heat, or exposed to organic solvents.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Why would the Luminex acquisition software display "Sample Empty" messages during analysis?

(1) The user did not properly aliquot the diluted beads, such that no beads were actually added to the wells (make sure that the bead concentrates are sonicated and vortexed well, then check the pipet tip to ensure that air bubbles were not drawn up)
(2) The user missed loading diluted beads to some wells, which is likely since the small volume is clear and difficult to visualize in the clear plastic plate (we have now addressed this customer difficulty by coloring each of the Buffer Reagent Kit components)
(3) The user applied too much vacuum pressure at some point during the wash steps, or allowed the pressure to spike even once, such that the filter membrane tore in a few wells releasing the beads (make sure that the vacuum manifold pressure is kept below 5mm/in Hg, depending on their system -- a good rule of thumb is that it should take a full 3-second count to GENTLY empty the wells of 200uL)
(4) The user did not properly sonicate and vortex the beads prior to dilution, such that the percent of bead aggregation was high and the instrument was unable to find enough single beads to meet the events/bead value designated by the customer (make sure that the Bead Concentrate tube is put into the waterbath all the way to the cap, since the tube is hollow until the top third)
(5) The user lost beads by shaking the plate too aggressively or handling it improperly (make sure that the orbital shaker is set to a speed that allows for maximum vortex in the wells without spillage)
(6) The user exposed the beads to an excess of light during storage or running of the assay, such that some but not all of the beads were photobleached and therefore falling outside the acceptable range for each bead region (make sure that the plate is covered on the top/sides with foil throughout the assay, away from Windows and spotlights, and that the bead component of the kits is stored in the dark)*
(7) There was a clog in the sample needle, such that the instrument was unable to take up enough sample to meet the number of events requested per bead region (suggest that the user follow the manual instructions for dislodging a clog, which include several Back Flush steps and may require removal of the needle for sonication with probe alignment).

* Some of the older Antibody Bead Kits still have clear plastic tops instead of black ones. In cases where customers store kits in lit refrigerators, or keep them open on the lab bench, even a few hours of light exposure is enough to photobleach beads. It is important to note, in general, that higher number bead regions are more susceptible to photobleaching. In order to draw conclusions about the source of the difficulty, we would ask to see the data, specifically the Masterplex QT file, which would enable us to examine the pattern of "Sample Empty" occurrences in addition to the bead counts per well.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

What are the Luminex beads made of?

The beads are made of polystyrene.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Citations & References (7)

Citations & References
Abstract
Novel three-dimensional biochip pulmonary sarcoidosis model.
Authors:Calcagno TM, Zhang C, Tian R, Ebrahimi B, Mirsaeidi M
Journal:PLoS One
PubMed ID:33539409
'Sarcoidosis is a multi-system disorder of granulomatous inflammation which most commonly affects the lungs. Its etiology and pathogenesis are not well defined in part due to the lack of reliable modeling. Here, we present the development of an in vitro three-dimensional lung-on-chip biochip designed to mimic granuloma formation. A lung ... More
Serum Cytokines Th1, Th2, and Th17 Expression Profiling in Active Lupus Nephritis-IV: From a Southern Chinese Han Population.
Authors:Sigdel KR, Duan L, Wang Y, Hu W, Wang N, Sun Q, Liu Q, Liu X, Hou X, Cheng A, Shi G, Zhang Y
Journal:Mediators Inflamm
PubMed ID:27738386
'Systemic lupus erythematosus (SLE) is a chronic autoimmune disease characterized by aberrant T cell immune response. Diffuse proliferative lupus nephritis (LN-IV) is the most common, severe, and active form of lupus nephritis. In this study, we investigated the production of Th1, Th2, and Th17 cytokines in prediction of active form ... More
Levels of interleukin (IL)-6 and IL-8 are elevated in serum and bronchoalveolar lavage fluid of haematological patients with invasive pulmonary aspergillosis.
Authors:Heldt S, Eigl S, Prattes J, Flick H, Rabensteiner J, Prüller F, Niedrist T, Neumeister P, Wölfler A, Strohmaier H, Krause R, Hoenigl M
Journal:Mycoses
PubMed ID:28877383
Aspergillus spp. have been shown to induce T-helper cell (Th) 1 and Th17 subsets resulting in elevated levels of several cytokines. The objective of this study was to analyse a bundle of cytokines in serum and bronchoalveolar lavage fluid (BALF) in patients with and without invasive pulmonary aspergillosis (IPA). This ... More
Association between Interleukin-6 Levels and Perioperative Fatigue in Gastric Adenocarcinoma Patients.
Authors:Wu JM, Yang HT, Ho TW, Shun SC, Lin MT
Journal:J Clin Med
PubMed ID:31010015
Gastric adenocarcinoma (GA), one of the most common gastrointestinal cancers worldwide, is often accompanied by cancer cachexia in the advanced stage owing to malnutrition and cancer-related symptoms. Although resection is the most effective curative procedure for GA patients, it may cause perioperative fatigue, worsening the extent of cancer cachexia. Although ... More
Stem Cells from Human Extracted Deciduous Teeth Expanded in Foetal Bovine and Human Sera Express Different Paracrine Factors After Exposure to Freshly Prepared Human Serum.
Authors:Haque N, Widera D, Abu Kasim NH
Journal:Adv Exp Med Biol
PubMed ID:30771186
The response of stem cells to paracrine factors within the host's body plays an important role in the regeneration process after transplantation. The aim of this study was to determine the viability and paracrine factor profile of stem cells from human extracted deciduous teeth (SHED) pre-cultivated in media supplemented with ... More