ProcartaPlex™ Rat Cytokine & Chemokine Panel, 22plex
ProcartaPlex™ Rat Cytokine & Chemokine Panel, 22plex
Invitrogen™

ProcartaPlex™ Rat Cytokine & Chemokine Panel, 22plex

El panel ProcartaPlex 22-Plex de citocina y quimiocina de rata permite el estudio de la función inmunitaria mediante el análisisMás información
Have Questions?
Número de catálogoCantidad
EPX220-30122-90196 pruebas
Número de catálogo EPX220-30122-901
Precio (CLP)
5.683.096
Each
Añadir al carro de la compra
Cantidad:
96 pruebas
Precio (CLP)
5.683.096
Each
Añadir al carro de la compra
El panel ProcartaPlex 22-Plex de citocina y quimiocina de rata permite el estudio de la función inmunitaria mediante el análisis de 22 proteínas diana en un solo pocillo a través de la tecnología Luminex xMAP. El panel se compone de dos subpaneles modulares que disponen de una amplia pantalla inicial para determinar los elementos diana de interés, así como estudios posteriores que analizan los subconjuntos funcionales específicos de citocinas y que pueden adquirirse por separado. Los subpaneles son totalmente combinables entre ellos o con los ensayos individuales simples correspondientes a los objetivos del panel.

Los paneles preconfigurados ProcartaPlex se han probado exhaustivamente para determinar la capacidad combinatoria, la interferencia y la reactividad cruzada de los analitos con el fin de proporcionar el mayor nivel de validación y precisión. Todos los paneles ProcartaPlex se suministran con los reactivos necesarios para realizar el ensayo.

Los paneles multiplex ProcartaPlex están disponibles en múltiples formatos en seis especies (humano, ratón, rata, primate no humano, porcino y canino). Visite nuestra página de inmunoensayos ProcartaPlex para obtener más información y consultar los productos disponibles.

Lista de objetivos [región de gránulos]:
Citocinas: G-CSF (CSF-3) [12], GM-CSF [42], IFN gamma [25], IL-1 alfa [14], IL-1 beta [19], IL-2 [20], IL-4 [21], IL-5 [27], IL-6 [18], IL-10 [15], IL-12p70 [39], IL-13 [35], IL-17A (CTLA-8) [53], TNF alfa [45]
Quimiocinas: Eotaxin (CCL11) [62], GRO alfa (CXCL1) [43], IP-10 (CXCL10) [22], MCP-1 (CCL2) [51], MCP-3 (CCL7) [48], MIP-1 alfa (CCL3) [47], MIP-2 [13], RANTES (CCL5) [44]

Acerca de los ensayos ProcartaPlex para la plataforma Luminex
Los inmunoensayos ProcartaPlex se basan en los principios de un ELISA tipo sándwich y utilizan dos anticuerpos altamente específicos que se enlazan a los diferentes epítopos de una proteína para cuantificar todas las proteínas diana simultáneamente mediante un instrumento Luminex. Para los ensayos multiplex ProcartaPlex se requieren tan solo 25 µl de plasma o suero, o 50 µl de sobrenadante del cultivo celular, y solo se necesitan cuatro horas para obtener los resultados analizados.

Las características incluyen:
• Resultados reproducibles y fiables: validados como panel según el estándar más alto del sector, incluidas las pruebas de combinación de proteínas diana y reactividad cruzada
• Más resultados por muestra: permite medir múltiples proteínas diana simultáneamente en una única muestra de 25–50 µL
• Tecnología Luminex consolidada: plataforma de multiplexing de referencia para detección y cuantificación de proteínas

Los ensayos ProcartaPlex utilizan la tecnología Luminex xMAP (método multianálito) para la detección y cuantificación simultáneas de hasta 65 proteínas diana en una única muestra de 25–50 µL de plasma, suero, sobrenadantes del cultivo celular y otros fluidos corporales.

Las microesferas de Luminex del ensayo de ProcartaPlex se tiñen internamente con proporciones precisas de fluoróforos rojos e infrarrojos para crear firmas específicas que pueden ser identificadas por los sistemas de detección Luminex xMAP (por ejemplo, Luminex 200, FLEXMAP 3D y MAGPIX). El ensayo ProcartaPlex, similar a un ELISA tipo sándwich, utiliza pares de anticuerpos emparejados para identificar la proteína de interés. En un ensayo multiplex, cada gránulo espectralmente único se etiqueta con anticuerpos específicos para una sola proteína diana, y las proteínas vinculadas se identifican con anticuerpos biotinilados y estreptavidina-R-ficoeritrina (RPE). La conjugación de anticuerpos específicos de proteínas en un gránulo distinto permite el análisis de varios elementos diana en un solo pocillo.

La diferencia más significativa entre un ensayo ProcartaPlex y uno ELISA es que el anticuerpo de captura del ensayo ProcartaPlex se conjuga en un gránulo y no se adsorbe en el pocillo de la microplaca, por lo que los reactivos del ensayo ProcartaPlex flotan en la solución. Para la detección, el instrumento Luminex 200, por ejemplo, contiene dos láseres, uno para distinguir la firma espectral de cada partícula y el segundo para cuantificar la cantidad de fluorescencia RPE, que es proporcional a la cantidad de proteína presente en la muestra. Los ensayos multiplex ProcartaPlex pueden determinar el perfil de más proteínas diana con mucha menos muestra en el mismo tiempo que se tarda en realizar un ELISA tipo sándwich tradicional.

Los paneles multiplex ProcartaPlex están disponibles en múltiples formatos en seis especies (humano, ratón, rata, primate no humano, porcino y canino). Visite thermofisher.com/procartaplex para obtener más información y consultar los productos disponibles.

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Intervalo del ensayoVer certificado de análisis
Sensibilidad del ensayoMenos del 15 %
Para utilizar con (equipo)Instrumentos Luminex™
FormatoKit multiplex
Línea de productosProcartaPlex
Tipo de muestraSobrenadantes de cultivo celular, suero y plasma, Plasma, Cell Culture Supernatants
Volumen de muestraSuero, plasma: 25 μl; CCS: 50 μl
Condiciones de envíoHielo húmedo
CombinabilityCombinable
Tipo de productoPanel
Cantidad96 pruebas
Research AreaImmunology, Cytokines, Chemokines
EspecieRata
Unit SizeEach
Contenido y almacenamiento
  • 2 viales de mezcla estándar de rata A (liofilizada)
  • 1 vial de mezcla de gránulos de captura de citocinas (50X)
  • 1 vial de mezcla de gránulos de captura de quimiocinas (1X)
  • 1 vial de mezcla de anticuerpos de detección biotinilada de citocinas (50X)
  • 1 vial de mezcla de anticuerpos de detección biotinilada de quimiocinas (50X)
  • 1 frasco de tampón de lectura (1X)
  • 1 frasco de tampón de lavado (10x)
  • 1 frasco de estreptavidina-PE (1X)
  • 1 frasco de tampón de ensayo universal (1 X)
  • 1 frasco de diluyente de anticuerpos de detección (1X)
  • Tira de 8 tubos
  • Película adhesiva
  • Placa de 96 pocillos de fondo plano, negra
  • Almacenar entre 2 °C y 8 °C

Preguntas frecuentes

What is the size of the Luminex beads you currently use?

The beads used in our Luminex instrument-compatible ProcartaPlex and QuantiGene Plex assays are 6.5 micron superparamagnetic beads.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

I am interested in performing Luminex assays using BioSource kits, and I have a Luminex xMAP system. Besides the kits and system, what other reagents and equipment will I need?

The following is a list of general lab supplies that are required for running BioSource immunoassays on the Luminex xMAP system:
1) Sonicating water bath
2) Orbital shaker
3) Vortexer
4) Repeating and/or multi-channel pipetter (not required, but recommended)
5) Calibrated adjustable precision pipettes, with disposable plastic tips
6) Glass/plastic tubes and racks for preparing reagents
7) Graduated cylinder and container for preparing wash solution
8) Aluminum foil
9) Deionized or distilled water.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Do the Luminex beads require special care in handling?

The Luminex beads should be protected from light because they are susceptible to photobleaching. We recommend protecting the beads by keeping containers covered with aluminum foil during all incubation steps, and exercising care during handling. The beads should not be frozen, subjected to excessive heat, or exposed to organic solvents.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Why would the Luminex acquisition software display "Sample Empty" messages during analysis?

(1) The user did not properly aliquot the diluted beads, such that no beads were actually added to the wells (make sure that the bead concentrates are sonicated and vortexed well, then check the pipet tip to ensure that air bubbles were not drawn up)
(2) The user missed loading diluted beads to some wells, which is likely since the small volume is clear and difficult to visualize in the clear plastic plate (we have now addressed this customer difficulty by coloring each of the Buffer Reagent Kit components)
(3) The user applied too much vacuum pressure at some point during the wash steps, or allowed the pressure to spike even once, such that the filter membrane tore in a few wells releasing the beads (make sure that the vacuum manifold pressure is kept below 5mm/in Hg, depending on their system -- a good rule of thumb is that it should take a full 3-second count to GENTLY empty the wells of 200uL)
(4) The user did not properly sonicate and vortex the beads prior to dilution, such that the percent of bead aggregation was high and the instrument was unable to find enough single beads to meet the events/bead value designated by the customer (make sure that the Bead Concentrate tube is put into the waterbath all the way to the cap, since the tube is hollow until the top third)
(5) The user lost beads by shaking the plate too aggressively or handling it improperly (make sure that the orbital shaker is set to a speed that allows for maximum vortex in the wells without spillage)
(6) The user exposed the beads to an excess of light during storage or running of the assay, such that some but not all of the beads were photobleached and therefore falling outside the acceptable range for each bead region (make sure that the plate is covered on the top/sides with foil throughout the assay, away from Windows and spotlights, and that the bead component of the kits is stored in the dark)*
(7) There was a clog in the sample needle, such that the instrument was unable to take up enough sample to meet the number of events requested per bead region (suggest that the user follow the manual instructions for dislodging a clog, which include several Back Flush steps and may require removal of the needle for sonication with probe alignment).

* Some of the older Antibody Bead Kits still have clear plastic tops instead of black ones. In cases where customers store kits in lit refrigerators, or keep them open on the lab bench, even a few hours of light exposure is enough to photobleach beads. It is important to note, in general, that higher number bead regions are more susceptible to photobleaching. In order to draw conclusions about the source of the difficulty, we would ask to see the data, specifically the Masterplex QT file, which would enable us to examine the pattern of "Sample Empty" occurrences in addition to the bead counts per well.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

What are the Luminex beads made of?

The beads are made of polystyrene.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Citations & References (3)

Citations & References
Abstract
HE4 Overexpression by Ovarian Cancer Promotes a Suppressive Tumor Immune Microenvironment and Enhanced Tumor and Macrophage PD-L1 Expression.
Authors:Rowswell-Turner RB, Singh RK, Urh A, Yano N, Kim KK, Khazan N, Pandita R, Sivagnanalingam U, Hovanesian V, James NE, Ribeiro JR, Kadambi S, Linehan DC, Moore RG
Journal:J Immunol
PubMed ID:33903172
'Ovarian cancer is a highly fatal malignancy characterized by early chemotherapy responsiveness but the eventual development of resistance. Immune targeting therapies are changing treatment paradigms for numerous cancer types but have had minimal success in ovarian cancer. Through retrospective patient sample analysis, we have determined that high human epididymis protein ... More
In-depth characterization of the neuroinflammatory reaction induced by peripheral surgery in an animal model.
Authors:Plaschke K, Schulz S, Rullof R, Weigand MA, Kopitz J
Journal:J Neural Transm (Vienna)
PubMed ID:30039507
Delirium is a common complication seen after surgery and anesthesia, in particular in older patients. Although the etiology of postoperative delirium is only incompletely understood, various lines of evidence suggest that proinflammatory signaling from the peripheral site of inflammation to central nervous system results in a decrease of cerebral acetylcholine ... More
Subcutaneous administration of a neutralizing IL-1ß antibody prolongs limb allograft survival.
Authors:Hautz T, Grahammer J, Moser D, Eberhart N, Zelger B, Zelger B, Blumer MJ, Drasche A, Wolfram D, Troppmair J, Öfner D, Schneeberger S
Journal:Am J Transplant
PubMed ID:29633557
Cytokine-expression profiles revealed IL-1ß highly upregulated in rejecting skin of limb allografts. We investigate the effect of intragraft treatment with a neutralizing IL-1ß antibody in limb transplantation. Following allogenic hind-limb transplantation, Lewis rats were either left untreated or treated with anti-lymphocyte serum + tacrolimus (baseline); baseline immunosuppression + anti-IL-1ß (1 mg/kg ... More