FluoSpheres™ Polystyrene Microspheres, 15 μm, crimson fluorescent (625/645), for blood flow determination
FluoSpheres™ Polystyrene Microspheres, 15 μm, crimson fluorescent (625/645), for blood flow determination
Invitrogen™

FluoSpheres™ Polystyrene Microspheres, 15 μm, crimson fluorescent (625/645), for blood flow determination

Las microesferas (también llamadas gránulos o partículas de látex) son partículas esféricas en el rango de tamaño coloidal que seMás información
Have Questions?
Número de catálogoCantidad
F8839
también denominado F-8839
10 mL
Número de catálogo F8839
también denominado F-8839
Precio (CLP)
-
Cantidad:
10 mL
Las microesferas (también llamadas gránulos o partículas de látex) son partículas esféricas en el rango de tamaño coloidal que se forman a partir de un polímero amorfo como el poliestireno. Nuestros gránulos Molecular Probes™ FluoShperes™ se fabrican utilizando poliestireno ultralimpio de alta calidad y se cargan con una variedad de nuestros colorantes patentados para crear gránulos intensamente fluorescentes que suelen mostrar poca o ninguna fotodecoloración, incluso cuando se excitan con una iluminación intensa necesaria para la microscopia de fluorescencia.

Las microesferas FluoSpheres™ en el rango de tamaño de 10–15 µm se diseñaron en concreto para estudios regionales de flujo de sangre en tejidos y órganos. Para estos tipos de estudios, normalmente se inyectan las microesferas en los lugares deseados del sistema circulatorio y finalmente se alojan en los capilares, de donde se pueden extraer y se puede cuantificar la fluorescencia. El uso de microesferas fluorescentes elimina los riesgos de radiación y los obstáculos de eliminación asociados con las microesferas etiquetadas radioactivamente. Se pueden discriminar múltiples (hasta siete o más con buena corrección espectral) microesferas FluoSpheres™ en circulación simultánea. Las microesferas que han sido perfundidas o inyectadas en tejidos y órganos conservan su fluorescencia después de un corte histológico en serie. Nuestras microesferas FluoSpheres™ para la determinación del flujo sanguíneo, que están disponibles en once colores fluorescentes distinguibles, también son compatibles con sistemas analizadores de flujo sanguíneo que realizan extracción y análisis automatizados.

Especificaciones de la microesfera FluoSpheres™:

Etiqueta (Ex/Em): Fluorescente carmesí (625/645)
Diámetro nominal del gránulo: 15 µm

Opciones para las microesferas fluorescentes para FluoSpheres™
Además de microesferas para estudios de flujo sanguíneo, examine nuestra oferta completa de productos de microesferas fluorescentes. Entre esos productos encontrará gránulos con las siguientes variaciones:
• Diez colores fluorescentes
• Diez diámetros nominales de gránulos: 0,02 µm, 0,04 µm, 0,1 µm, 0,2 µm, 0,5 µm, 1,0 µm, 2,0 µm, 4,0 µm, 10,0 µm y 15,0 µm
• Cuatro modificaciones superficiales para el acoplamiento de proteínas: carboxilato, sulfato, aldehído-sulfato, amina
• Microesferas que además están preacopladas con estreptavidina, NeutrAvidin, biotina, europio y platino

Opciones de microesferas sin teñir
También ofrecemos cientos de opciones de microesferas sin surfactantes UltraClean™ para aplicaciones de investigación y comerciales.

Le prepararemos un producto de microesferas personalizado
Preparamos pedidos a medida a petición del cliente. Por ejemplo, los gránulos de FluoSpheres™ pueden prepararse con intensidades inferiores a las de nuestra selección regular, una característica adecuada en algunas aplicaciones multicolores. Nuestro servicio de conjugación personalizada es eficiente y confidencial, y garantizamos la calidad de nuestro trabajo. Contamos con la certificación ISO 9001:2000.

Solo para uso en investigación. No apto para uso diagnóstico o terapéutico en animales o humanos.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Concentración1,0 x 106 gránulos⁄ml
Línea de productosFLUOSPHERES
Cantidad10 mL
Condiciones de envíoTemperatura ambiente
ColorCarmesí
Diámetro (métrico)15 μm
MaterialPoliestireno
Tipo de productoMicroesfera
Unit SizeEach
Contenido y almacenamiento
Almacenar en el refrigerador (2–8 °C) y proteger de la luz.

Preguntas frecuentes

I want to use fluorescent microspheres for blood tracing studies. What functional group should be on the surface?

We offer FluoSpheres fluorescent microspheres for tracer studies that are 1, 10 and 15 µm in diameter, with various wavelengths. If those sizes or available colors are not optimal for your application, then we recommend carboxylate-modified microspheres, which are available in a wide range of sizes and colors.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I want to use fluorescent microspheres for blood tracing studies. What functional group should be on the surface of the beads?

We offer FluoSpheres fluorescent microspheres that are available in 10 and 15 µm diameters, with various wavelengths, for tracer studies. If those sizes or available colors are not optimal for your system, then we recommend the carboxylate-modified microspheres, which are available in a wide range of sizes and colors.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What is the warranty for FluoSpheres microspheres?

The warranty period for FluoSpheres microspheres is 1-year from the date of shipment.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

After washing and centrifugation, there was only a very small pellet left of my microsphere beads and the solution was transparent. Why is this?

Centrifugation is not an effective way to collect smaller microspheres; many particles remain in the solution even if you can visualize a small pellet. For beads less than 1 µm in diameter, we recommend washing by either:

Cross-flow filtration, as these particles have a very high compression modulus and can withstand high g-forces without risk of harm or dialysis with a 500 kDa MWCO
Note: Microspheres greater than 1 µm in diameter can be centrifuged at 1,300 rpm.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I've had my microspheres for over a year, and I'm wondering if they're still good to use. What are some good ways to check their functionality?

Bacterial contamination is the most common cause of microspheres becoming unusable. Many of our particles are supplied with a low level of sodium azide to prevent bacterial contamination, but sometimes this can still occur. Bacterial contamination is best assessed by plating on appropriate growth medium and checking the plates after 72 hr.

Find additional tips, troubleshooting help, and resources within ourMicrospheres Support Center.

Citations & References (4)

Citations & References
Abstract
Fractal nature of regional ventilation distribution.
Authors:Altemeier WA, McKinney S, Glenny RW
Journal:J Appl Physiol
PubMed ID:10797111
'High-resolution measurements of pulmonary perfusion reveal substantial spatial heterogeneity that is fractally distributed. This observation led to the hypothesis that the vascular tree is the principal determinant of regional blood flow. Recent studies using aerosol deposition show similar ventilation heterogeneity that is closely correlated with perfusion. We hypothesize that ventilation ... More
Validation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
Authors:Glenny RW, Bernard S, Brinkley M
Journal:J Appl Physiol
PubMed ID:8335595
'Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 microns diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ... More
Development of a fluorescent microsphere technique for rapid histological determination of cerebral blood flow.
Authors:Eucker SA, Hoffman BD, Natesh R, Ralston J, Armstead WM, Margulies SS,
Journal:Brain Res
PubMed ID:20193669
'The purpose of this study was to develop a more efficient fluorescent microsphere method to facilitate the rapid use of the histological technique and to enable its use in large tissue regions. Using fluorescent plate/slide imaging technology and automated detection and analysis software, we were able to rapidly image, detect, ... More
Fluorescent microspheres to measure organ perfusion: validation of a simplified sample processing technique.
Authors:Van Oosterhout MF, Willigers HM, Reneman RS, Prinzen FW
Journal:Am J Physiol
PubMed ID:7653638
A disadvantage of nonradioactive microsphere techniques is that the processing of samples is time-consuming and complex. We developed and validated a simplified processing method for the fluorescent microsphere (FM) technique. In seven anesthetized dogs with coronary artery stenosis up to six different FM and five different radioactivity labeled microspheres (RM) ... More