Safety-Guard Series II System
Safety-Guard Series II System
Thermo Scientific™

Safety-Guard Series II System

Thermo Scientific™ Safety-Guard Series II of radiation detection systems offer optimized protection against illicit trafficking of nuclear materials.
Have Questions?
Número de catálogo SGSII
Precio (CLP)
-

Thermo Scientific™ Safety-Guard Series II of radiation detection systems offer optimized protection against illicit trafficking of nuclear materials. Offer significant gains in detection sensitivity for screening packages, people, or vehicles, for incident prevention and response.

Over 1400 systems installed worldwide at borders, seaports, couriers and government buildings.
  • Modular system components for maximum protection
  • Natural Background Reduction (NBR) technology
  • Large-area, premium-grade scintillation detectors
  • Protects: Courier services, Postal service, food storage/handling, facilities, transportation services
  • Optional neutron detectors enhance detection of Special Nuclear Materials (SNM)
  • Self-shielding algorithm
  • Enhanced neutron alarm
  • Sum channels
  • External modem support
  • Camera (optional)

Ordering Alerts:

Configurable system designed with our Technical Support to provide maximum protection and coverage

Recommended for:

  • Borders
  • Airports
  • Seaports
  • Government Buildings
  • Power Plants
  • Financial Institutions
  • Banks
  • Mints
  • Military Bases
  • Postal Services
  • Courier Services
  • Public Utilities
  • Embassies
Especificaciones
AlarmasGamma Gross, NBR Cs-137, NBR Co-60, low-energy channel, Neutron (option)
Memoria de datosData logging on hard drive
DescripciónControlador: Serie II
Área de la superficie de detecciónapprox. 0.5 m² per panel
Tipo de detectorPlastic Scintillation
Detectoresmax 8 modules either gamma or neutron
Tipo de pantalla17 in. TFT monitor (integrated 6.5 in. TFT optional)
Intervalo de energíalowest threshold approx. 30 keV (Gamma)
Velocidad de falsa alarma1:10000
Tiempo de medición200 msec.
Requisitos de alimentación110 to 240 VAC, 50 to 65 Hz
Tipo de radiaciónGamma
Humedad relativa10% to 90%, Non-Condensing
Sensibilidadapprox. 150000 cps/µSv/h per panel (Gamma)
Tamaño (imperial)Controller: 19.5 x 19 x 7 in.; 500G Plastic Detector: 2 x 5 x 48 in.; 1500G Plastic Detector: 2 x 5 x 48 in.; 500G Enclosure: 8 x 8 x 60 in.; 1500G Enclosure: 12 x 18 x 72 in.
Tamaño (métrico)Controller: 50 x 49.5 x 18 cm; 500G Plastic Detector: 5 x 12.5 x 122 cm; 1500G Plastic Detector: 5 x 38 x 122 cm; 500G Enclosure: 20.5 x 20.5 x 152 cm; 1500G Enclosure: 30.5 x 45.5 x 183 cm
Temperatura de funcionamiento (imperial)Panels: -13°F to +122°F, Indoor equipment: 32°F to 104°F
Temperatura de funcionamiento (métrico)Panels: -25°C to +50°C, Indoor equipment: 0°C to 40°C
Peso (imperial)500G detector: 200 lb.; 1500G Detector: 340 lb.
Volumen de detección24 L
Interfaz de usuarioWindows 7
Peso (métrico)500G detector: 90.5 kg; 1500G Detector: 154 kg
Unit SizeEach