Thermo Scientific™

Sentinel PRO Environmental Mass Spectrometer

Catalog number: SENTINELPRO
Thermo Scientific™

Sentinel PRO Environmental Mass Spectrometer

Catalog number: SENTINELPRO
Ensure plant safety by enabling leak detection and correction before any toxic hazard is created with the Thermo Scientific™ Sentinel PRO Environmental Mass Spectrometer. This next-generation environmental mass spectrometer is engineered to help plants monitor fugitive emissions of toxic organic vapors, protecting workers and surrounding environment from hazardous exposure.
 
Catalog Number
SENTINELPRO
Unit Size
Each
Product Type
Sentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass Spectrometer
Price (EUR)
Full specifications
Product TypeSentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass Spectrometer
Ambient Temperature12°C to 40°C
Communication ProtocolsModbus serial RS232/422/485, Siemens 3964R, VGCP and PVGCP; optional via protocol converters: Modbus Ethernet TCP/IP and Profibus DP
Mass RangeAdjustable, 1 to 150 amu at 1000 eV ion acceleration voltage, 1 to 300 amu at 500 eV ion acceleration voltage
Analysis Time0.3 to 1.0 sec. per gas component
Analyzer TypeScanning Magnetic Sector Mass Spectrometer with Enclosed Electron Impact Dual Filament Ion Source
Area Classification OptionsGeneral Purpose; Z-purged Class 1 Div 2 (optional); ATEX Zone 1, IIC T3 (optional)
Depth (English)2.7 ft.
Depth (Metric)0.8 m
Dynamic Range10 ppb to 100 ppm or 100 ppb to 1000 ppm
Height (English)GP: 5 ft., Ex: 6 ft.
Height (Metric)GP: 1.5 m, Ex: 1.8 m
No. of Calibration Gas InletsUp to 6 (standard); optional to 24
No. of Sample Stream InletsUp to 31 or 63 (standard); optional to 126
Power115/230 V, Consumption GP: 2.0 kVA; Ex: 2.5 kVA
Precision≤±0.5 ppm over 24 hours, ≤±1 ppm at 10 ppm concentration over 1 month
Weight (English)530 lb.
Weight (Metric)240 kg
Width (English)3.3 ft.
Width (Metric)1 m
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeProduct TypePrice (EUR)
SENTINELPROFull specifications
EachSentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass SpectrometerRequest A Quote
Product TypeSentinel PRO Environmental Ambient Air Trace VOC Gas Analysis Mass Spectrometer
Ambient Temperature12°C to 40°C
Communication ProtocolsModbus serial RS232/422/485, Siemens 3964R, VGCP and PVGCP; optional via protocol converters: Modbus Ethernet TCP/IP and Profibus DP
Mass RangeAdjustable, 1 to 150 amu at 1000 eV ion acceleration voltage, 1 to 300 amu at 500 eV ion acceleration voltage
Analysis Time0.3 to 1.0 sec. per gas component
Analyzer TypeScanning Magnetic Sector Mass Spectrometer with Enclosed Electron Impact Dual Filament Ion Source
Area Classification OptionsGeneral Purpose; Z-purged Class 1 Div 2 (optional); ATEX Zone 1, IIC T3 (optional)
Depth (English)2.7 ft.
Depth (Metric)0.8 m
Dynamic Range10 ppb to 100 ppm or 100 ppb to 1000 ppm
Height (English)GP: 5 ft., Ex: 6 ft.
Height (Metric)GP: 1.5 m, Ex: 1.8 m
No. of Calibration Gas InletsUp to 6 (standard); optional to 24
No. of Sample Stream InletsUp to 31 or 63 (standard); optional to 126
Power115/230 V, Consumption GP: 2.0 kVA; Ex: 2.5 kVA
Precision≤±0.5 ppm over 24 hours, ≤±1 ppm at 10 ppm concentration over 1 month
Weight (English)530 lb.
Weight (Metric)240 kg
Width (English)3.3 ft.
Width (Metric)1 m
Unit SizeEach
Showing 1 of 1
The fast, precise and reliable Sentinel PRO environmental mass spectrometer can monitor 100 or more sample points within 15 minutes. It features species-specific detection of a number of volatile organic compounds (VOCs) in the 1ppm - 100ppm range. A rugged fault-tolerant design ensures availability exceeds 99.7% and simplified maintenance procedures make it easy to own. A single Sentinel PRO analyzer can replace an entire rack of less sensitive, discrete analyzers to improve detection capabilities and significantly reduce maintenance and ongoing operating costs.

Increased Sensitivity, Precision, Accuracy, and Mass Range:
  • Completely redesigned electronics, incorporating higher specification components
  • Capable of monitoring 100 or more sample points within 15 minutes
  • Species-specific detection of VOCs in the 1ppm - 100ppm range
  • Reliable, fault-tolerant design for availability of greater than 99.7%
  • Significantly enhanced analyzer control
  • Enhanced connectivity to DCS systems and off-line data manipulation packages
Features:
  • Offers high number of sample points that can be located close to potential leak points (i.e. valve stems, etc.)
  • Unique rapid multi-stream sampler (RMS) with 32 or 64 ports
  • Stable with 30- to 90-day automated calibration interval
  • Complete service access from the front of the system, reducing the effective footprint
  • Small footprint with no large shelter required
  • Minimal maintenance requirements
  • Thermo Scientific™ GasWorks software

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text