Thermo Scientific™

LTQ XL™ Linear Ion Trap Mass Spectrometer

Catalog number: IQLAAEGAAVFACZMAIK
Thermo Scientific™

LTQ XL™ Linear Ion Trap Mass Spectrometer

Catalog number: IQLAAEGAAVFACZMAIK

Obtain high sensitivity full scan MS along with in-depth MSn (CRM) capabilities with the Thermo Scientific™ LTQ XL™ linear ion trap mass spectrometer. A single quadrupole offers Selected Ion Monitoring. A triple quadrupole adds Selected Reaction Monitoring. A linear ion trap goes further by enabling Consecutive Reaction Monitoring where a selected ion is fragmented into a product ion and the resulting product ion further fragmented in additional consecutive steps. Each additional fragmentation step makes compound identification more certain and facilitates structural characterization.

 
Catalog Number
IQLAAEGAAVFACZMAIK
Unit Size
Each
Description
LTQ XL Linear Ion Trap Mass Spectrometer
Price (EUR)
Full specifications
Mass Range15 to 200 m/z, 50 to 2000 m/z, 200 to 4000 m/z
Resolution0.15 FWHM, 0.3 FWHM, 0.45 FWHM, 0.7 FWHM, 3 FWHM
Scan RatesMSn for n = 1 through 10
Polarity Switching<100 msec between positive and negative MS Scan Power
SensitivityHeated Electrospray Ionization (HESI) - A Loop Injection of 2 μL of a 125 fg/μL Solution of Reserpine (250 Femtograms Total Sample). Will Produce a Minimum Signal-to-Noise Ratio of 100:1)
Amperage15 A
Hertz50/60 Hz
Voltage230 V
DescriptionLTQ XL Linear Ion Trap Mass Spectrometer
Weight (Metric)120 kg
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (EUR)
IQLAAEGAAVFACZMAIKFull specifications
EachLTQ XL Linear Ion Trap Mass SpectrometerRequest A Quote
Mass Range15 to 200 m/z, 50 to 2000 m/z, 200 to 4000 m/z
Resolution0.15 FWHM, 0.3 FWHM, 0.45 FWHM, 0.7 FWHM, 3 FWHM
Scan RatesMSn for n = 1 through 10
Polarity Switching<100 msec between positive and negative MS Scan Power
SensitivityHeated Electrospray Ionization (HESI) - A Loop Injection of 2 μL of a 125 fg/μL Solution of Reserpine (250 Femtograms Total Sample). Will Produce a Minimum Signal-to-Noise Ratio of 100:1)
Amperage15 A
Hertz50/60 Hz
Voltage230 V
DescriptionLTQ XL Linear Ion Trap Mass Spectrometer
Weight (Metric)120 kg
Unit SizeEach
Showing 1 of 1

The LTQ XL ion trap MS extends the legendary MSn performance of the LTQ ion trap, incorporating more techniques to generate structural information through innovations in Thermo Scientific ion trap technology.

  • Unparalleled sensitivity and unmatched MSn spectral quality
  • Pulsed Q dissociation (PQD) for generating more fragments and extending the low mass range
  • High-resolution isolation (HRI) enables isolation of isobaric mass peaks for cleaner MSn spectra
  • Ultra-fast polarity switching for high sensitivity analysis of unknowns
  • Automated data-dependent neutral loss for PTM and biotransformation analyses
  • Excellent charge state determinations with Ultra ZoomScan™

The LTQ XL supplies outstanding sensitivity and abundant structural information for:

  • Protein identification and quantitative differential expression analysis
  • Biomarker studies and PTM identification
  • Metabolite identification and quantification
  • Tissue imaging
  • High-speed LC methods
For Research Use Only. Not for use in diagnostic procedures.