Solución de chapado en oro, sin electrodos, contenido de metal ≈ 3,7 g/l, Thermo Scientific Chemicals
Thermo Scientific Chemicals

Solución de chapado en oro, sin electrodos, contenido de metal ≈ 3,7 g/l, Thermo Scientific Chemicals

Para recubrimiento de níquel o cobre
Have Questions?
Cambiar vistabuttonViewtableView
Cantidad:
250 mL
1 L
Número de catálogo 042307.K2
también denominado 042307-K2
Precio (EUR)
-
Cantidad:
1 L
Pedido a granel o personalizado
Especificaciones
Nombre del producto químico o materialGold plating solution
ColorDe incoloro a amarillo
Información de PUNTOSClase de peligro de transporte:8; grupo de embalaje:III; Nombre del producto expedido:LÍQUIDOS CORROSIVOS, TÓXICO, SIN ESPECIFICAR
Peligro para la salud 1H311-H314-H332-H335.
Peligro para la salud 2Declaración de GHS H
H301-H311-H331-H314
Tóxico en caso de ingestión.
Tóxico en contacto con la piel.
Tóxico en caso de inhalación.
Provoca quemaduras graves en la piel y lesiones oculares.
Ver más
For coating nickel or copper

This Thermo Scientific Chemicals brand product was originally part of the Alfa Aesar product portfolio. Some documentation and label information may refer to the legacy brand. The original Alfa Aesar product / item code or SKU reference has not changed as a part of the brand transition to Thermo Scientific Chemicals.

RUO – Research Use Only

Preguntas frecuentes

How should I prepare the surface of nickel or copper for gold plating with Gold plating solution, electroless, metal content≈3.7g/L?

Prior to plating, we recommend that you thoroughly clean the surface of the object to be plated. First, use a brush and a mild detergent to scrub the surface and then rinse thoroughly with purified water. Next, use a dilute hydrochloric (HCl) acid solution to remove any surface oxides and rinse thoroughly with purified water.

What instructions should I use for the Gold plating solution, electroless, metal content≈3.7g/L?

The gold plating solution can be kept in a glass beaker directly heated on a hot plate. The pH can drop with use, and we recommend adjusting the pH to the optimal range by adding small amounts of concentrated ammonium hydroxide.

What is the coverage of the Gold plating solution, electroless, metal content≈3.7g/L?

Assuming 50% of the gold is used, the coverage will be approximately 4096 cm2/L (635 in2/L or 2400 in2/gal) for an average thickness of 5 microinches of gold.

What is the deposition rate for the Gold plating solution, electroless, metal content≈3.7g/L?

The deposition rate for the Gold plating solution, electroless, metal content≈3.7g/L is 0.2-0.3 microinches/minute for a maximum thickness of 7-8 microinches in 30 minutes at 160°F (71°C). The thickness of gold can be increased to up to 15 microinches at a higher temperature of 175°F (80°C).

What are the operating conditions for the Gold plating solution, electroless, metal content≈3.7g/L?

The operating conditions for the Gold plating solution, electroless, metal content≈3.7 g/L are as follows:

  • pH 5.0-5.5
  • Agitation preferred
  • Time: at least 15 minutes
  • Temperature: 60-71°C (140-160°F)