Kit de proliferación celular CellTrace™ Yellow, para citometría de flujo
Kit de proliferación celular CellTrace™ Yellow, para citometría de flujo
Invitrogen™

Kit de proliferación celular CellTrace™ Yellow, para citometría de flujo

El kit de proliferación de células CellTrace™ Yellow se emplea para el etiquetado de células in vitro e in vivoMás información
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoCantidad
C3457320 ensayos
C34567180 ensayos
Número de catálogo C34573
Precio (EUR)
146,00
Each
Añadir al carro de la compra
Cantidad:
20 ensayos
Precio (EUR)
146,00
Each
Añadir al carro de la compra

El kit de proliferación de células CellTrace™ Yellow se emplea para el etiquetado de células in vitro e in vivo con el fin de determinar varias generaciones mediante una dilución con tintes a través de citometría de flujo. Este reactivo está diseñado específicamente para la excitación mediante un láser de 532 nm o 561 nm, y se puede multiplexar fácilmente con reactivos y anticuerpos excitados por otros láseres de uso común.

Rendimiento superior: la tinción brillante de rendimiento superior con un solo pico permite la visualización de múltiples generaciones
Estabilidad de la señal a largo plazo: se conserva bien en las células durante varios días tras la tinción
Versátil: varios colores disponibles para combinar fácilmente con anticuerpos o marcadores de la función celular
Sencillo: protocolo de tinción sólido

Tinción fluorescente superior
Un análisis correcto de proliferación mediante dilución de tinte requiere un tinte muy brillante para distinguir las células etiquetadas con fluorescencia de las autofluorescencias después de varias divisiones celulares. La intensa tinción fluorescente proporcionada por el colorante CellTrace Yellow permite visualizar seis o más generaciones de células proliferantes antes de que la señal se vea desbordada por la autofluorescencia celular intrínseca. Este kit permite obtener resultados de tinción homogéneos y consistentes con muy poca variación de fluorescencia entre las células de una población, por lo que se pueden ver distintas generaciones sin necesidad de un software de modelado complejo.

Retención de la señal a largo plazo
A diferencia de los tintes que etiquetan la membrana lipídica de las células, la tinción de CellTrace Yellow atraviesa fácilmente la membrana plasmática y se adhiere de manera covalente al interior de las células donde el colorante fluorescente estable proporciona una señal consistente, incluso después de varios días en un entorno de cultivo celular. La tinción CellTrace Yellow se adhiere covalentemente a todas las aminas libres en la superficie y el interior de las células y muestra poca citotoxicidad, con un efecto mínimo observado en la capacidad proliferativa o biología de las células.

Fácil multiplexado con otros fluoróforos
La excitación en Yellow a 546 nm y de emisión a 579 nm del colorante CellTrace Yellow lo hace ideal para multiplexar debido al solapamiento espectral limitado con otros tintes comunes (Alexa Fluor™488 y FITC) y proteínas fluorescentes verdes (GFP).

Utilice el Spectraviewer para ayudarle a planear sus experimentos.

Protocolo de tinción sencillo y sólido
El kit de proliferación de células CellTrace Yellow contiene viales prácticos de un solo uso de colorante seco que permiten realizar experimentos a pequeña escala sin necesidad preparar cantidades excesivas de colorante. Se prepara una solución madre mediante la disolución del contenido de un vial en dimetilsulfóxido (DMSO) anhidro antes del uso. Para teñir 1 ml de células en un medio sin proteínas, se suele emplear 1 µl de esta solución madre. Las células deben teñirse durante 20 minutos a temperatura ambiente mediante una agitación suave. A continuación, un breve lavado con un medio completo eliminará cualquier coorante que pudiera quedar en la solución.

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.

Especificaciones
Método de detecciónFluorescente
Tipo de coloranteCellTrace™ Yellow
FormularioSólido
FormatoTubo(s)
Cantidad20 ensayos
Tipo de reactivoCFSE y compuestos relacionados
Condiciones de envíoTemperatura ambiente
SolubilidadDMSO (dimetilsulfóxido)
Emission579
Excitation Wavelength Range532 o 561, 532
Para utilizar con (aplicación)Ensayo de proliferación
Para utilizar con (equipo)Citómetro de flujo
Línea de productosCellTrace
Tipo de productoKit de proliferación celular
Unit SizeEach
Contenido y almacenamiento
  • 1 vial de colorante amarillo CellTrace™
  • 100 µl DMSO
  • Almacenar en congelador (de -5 °C a -30 °C)

Preguntas frecuentes

I would like to label two cell populations with two different CellTrace reagents and then co-culture these cells. Will the CellTrace reagent leave the cells to stain other cells?

We have not tested the use of the CellTrace reagents for co-culture applications. In theory, this may work, but you would have to test this on your cells of interest.

Find additional tips, troubleshooting help, and resources within our Cell Tracing and Tracking Support Center.

With the CellTrace cell proliferation kits, for flow cytomtery, I am getting only one broad peak on my histogram instead of multiple peaks. What is causing this?

A single broad peak is usually caused by using too high a concentration of dye and/or too long an incubation time.

Find additional tips, troubleshooting help, and resources within our Flow Cytometry Support Center.

What cellular components do the CellTrace Proliferation dyes label?

The dyes provided in the CellTrace Proliferation kits are amine-reactive dyes that are considered general cytoplasmic stains. They may bind to various membrane proteins, organelles as well as components in the cytoplasm. They are not known to localize in any specific organelles.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

With the CellTrace Yellow Cell Proliferation Kit, for flow cytometry, I do not see a clear discrimination between generations, only a single broad peak. Why is this occurring?

A single broad peak may be observed if the dye concentration used is too high or if the dye incubation period is too long. We recommend reducing the amount of dye used and/or the incubation period.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

When would I use CellTrace Yellow Dye?

We recommend using the CellTrace Yellow Dye if you have either a 532 or 561 nm laser available on your flow cytometer and you want to use the other lasers and channels for other commonly used fluorophores.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Citations & References (6)

Citations & References
Abstract
Deriving Quantitative Cell Biological Information from Dye-Dilution Lymphocyte Proliferation Experiments.
Authors:Roy K, Shokhirev MN, Mitchell S, Hoffmann A,
Journal:Methods Mol Biol
PubMed ID:29388101
'The dye-dilution assay is a powerful tool to study lymphocyte expansion dynamics. By combining time course dye-dilution experiments with computational analysis, quantitative information about cell biological parameters, such as percentage of cells dividing, time of division, and time of death, can be produced. Here, we describe the method to generate ... More
Triple co-culture of human alveolar epithelium, endothelium and macrophages for studying the interaction of nanocarriers with the air-blood barrier.
Authors:Costa A, de Souza Carvalho-Wodarz C, Seabra V, Sarmento B, Lehr CM,
Journal:Acta Biomater
PubMed ID:31004840
'Predictive in vitro models are valuable alternatives to animal experiments for evaluating the transport of molecules and (nano)particles across biological barriers. In this work, an improved triple co-culture of air-blood barrier was set-up, being exclusively constituted by human cell lines that allowed to perform experiments at air-liquid interface. Epithelial NCI-H441 ... More
Isolation and Activation of Murine Lymphocytes.
Authors:Lim JF, Berger H, Su IH
Journal:J Vis Exp
PubMed ID:27842342
'B and T cells, with their extremely diverse antigen-receptor repertoires, have the ability to mount specific immune responses against almost any invading pathogen(1,2). Understandably, such intricate abilities are controlled by a large number of molecules involved in various cellular processes to ensure timely and spatially regulated immune responses(3). Here, we ... More
Superior properties of CellTrace Yellow™ as a division tracking dye for human and murine lymphocytes.
Authors:Tempany JC, Zhou JH, Hodgkin PD, Bryant VL,
Journal:Immunol Cell Biol
PubMed ID:29363164
The discovery of cell division tracking properties of 5-(and-6)-carboxyfluorescein diacetate succinimidyl ester (CFSE) by Lyons and Parish in 1994 led to a broad range of new methods and numerous important biological discoveries. After labeling, CFSE is attached to free amine groups and intracellular proteins in the cytoplasm and nucleus of ... More
Autoreactive, Low-Affinity T Cells Preferentially Drive Differentiation of Short-Lived Memory B Cells at the Expense of Germinal Center Maintenance.
Authors:Jain RW, Parham KA, Tesfagiorgis Y, Craig HC, Romanchik E, Kerfoot SM,
Journal:Cell Rep
PubMed ID:30566861
B cell fate decisions within a germinal center (GC) are critical to determining the outcome of the immune response to a given antigen. Here, we characterize GC kinetics and B cell fate choices in a response to the autoantigen myelin oligodendrocyte glycoprotein (MOG) and compare the response with a standard ... More