Obtain predictable, high-resolution, high efficiency separations of food sugars, namely mono-, di-, tri-, tetra- and pentasaccharides in various types of food samples. Thermo Scientific™ Dionex™ CarboPac™ PA210-Fast-4μm IC columns resolve and quantify glucose, galactose, fructose, sucrose, rhamnose, stachyose, raffinose, and verbascose in food and beverage samples in less than 20 minutes.

 
Catalog Number
088954
Unit Size
Each
Column Type
Analytical Column
Diameter (Metric)
2 mm
Length (Metric)
150 mm
Price (EUR)
Price: 1 790,00
Your price:
Full specifications
Quantity
Anion Exchange Capacity17 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)2 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Column Type
Analytical Column
Diameter (Metric)
4 mm
Length (Metric)
150 mm
Price (EUR)
Price: 1 790,00
Your price:
Full specifications
Quantity
Anion Exchange Capacity66 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)4 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Column Type
Guard Column
Diameter (Metric)
2 mm
Length (Metric)
30 mm
Price (EUR)
Price: 571,00
Your price:
Full specifications
Quantity
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)2 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Column Type
Guard Column
Diameter (Metric)
4 mm
Length (Metric)
30 mm
Price (EUR)
Price: 571,00
Online price: 485,35
Your price:
Full specifications
Quantity
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)4 mm
Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeColumn TypeDiameter (Metric)Length (Metric)Price (EUR)Quantity
088954Full specifications
EachAnalytical Column2 mm150 mm
Price: 1 790,00
Your price:
Anion Exchange Capacity17 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)2 mm
Unit SizeEach
088953Full specifications
EachAnalytical Column4 mm150 mm
Price: 1 790,00
Your price:
Anion Exchange Capacity66 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)4 mm
Unit SizeEach
088956Full specifications
EachGuard Column2 mm30 mm
Price: 571,00
Your price:
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)2 mm
Unit SizeEach
088955Full specifications
EachGuard Column4 mm30 mm
Price: 571,00
Online price: 485,35
Your price:
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)4 mm
Unit SizeEach
Showing 4 of 4
High efficiency, and predictable separation of simple sugars
  • Separation and accurate quantification of mono-, di-, tri-, tetra- and pentasaccharides
  • Food and beverage samples

Column features
  • Anion-exchange column
  • Fast analysis and short separation times
  • High efficiency
  • High resolution
  • High reproducibility

Column Formats
  • Microbore (2mm) and standard bore (4mm) formats
  • Shorter 150mm format columns provide faster separations
  • 4μm resin particles provide more efficient separations resulting in more accurate peak integration and more reliable results

Use with PAD Systems

The Dionex CarboPac PA 210-4μm anion-exchange column is used with pulsed amperometric detection (PAD) systems and permits the direct quantification of nonderivatized carbohydrates with minimal sample preparation.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text