Thermo Scientific™

Pierce™ MS-Compatible Magnetic IP Kits

Catalog number: 90408
Thermo Scientific™

Pierce™ MS-Compatible Magnetic IP Kits

Catalog number: 90408
Immunoprecipitation is often necessary for the detection and quantitation of low-abundance proteins or rare signaling events. Mass spectrometry analysis relies on two methods for the detection of low-abundance proteins: single reaction monitoring (SRM) and parallel reaction monitoring (PRM), which enable isolation, scheduling, and quantitation of selected proteotypic peptides. These IP kits have been optimized for efficient immunoprecipitation and co-immunoprecipitation of target proteins, and are directly compatible with downstream MS sample preparation and analysis.
 
Catalog Number
90408
Unit Size
40 reactions
Description
Streptavidin Magnetic Beads
Price (EUR)
Price: 634,00
Your price:
Availability
-
Full specifications
Quantity
DescriptionStreptavidin Magnetic Beads
For Use With (Equipment)KingFisher™ Flex, Magnetic Stand
Product TypeMagnetic IP Kit
Product LinePierce™
Sufficient For40 Reactions
Starting MaterialProtein Samples, Cell Lysate
Final Product TypeProtein
Detection MethodMass Spectrometry
FormatKit
Workflow StepSample Enrichment
Quantity1 Kit
For Use With (Application)Mass Spectrometry
Unit Size40 reactions
Catalog Number
Unit Size
40 reactions
Description
Protein A/G Magnetic Beads
Price (EUR)
Price: 636,00
Your price:
Availability
-
Full specifications
Quantity
DescriptionProtein A/G Magnetic Beads
For Use With (Equipment)KingFisher™ Flex, Magnetic Stand
Product TypeMagnetic IP Kit
Product LinePierce™
Sufficient For40 Reactions
Starting MaterialProtein Samples, Cell Lysate
Final Product TypeProtein
Detection MethodMass Spectrometry
FormatKit
Workflow StepSample Enrichment
Quantity1 Kit
For Use With (Application)Mass Spectrometry
Unit Size40 reactions
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDescriptionPrice (EUR)AvailabilityQuantity
90408Full specifications
40 reactionsStreptavidin Magnetic Beads
Price: 634,00
Your price:
-
DescriptionStreptavidin Magnetic Beads
For Use With (Equipment)KingFisher™ Flex, Magnetic Stand
Product TypeMagnetic IP Kit
Product LinePierce™
Sufficient For40 Reactions
Starting MaterialProtein Samples, Cell Lysate
Final Product TypeProtein
Detection MethodMass Spectrometry
FormatKit
Workflow StepSample Enrichment
Quantity1 Kit
For Use With (Application)Mass Spectrometry
Unit Size40 reactions
90409Full specifications
40 reactionsProtein A/G Magnetic Beads
Price: 636,00
Your price:
-
DescriptionProtein A/G Magnetic Beads
For Use With (Equipment)KingFisher™ Flex, Magnetic Stand
Product TypeMagnetic IP Kit
Product LinePierce™
Sufficient For40 Reactions
Starting MaterialProtein Samples, Cell Lysate
Final Product TypeProtein
Detection MethodMass Spectrometry
FormatKit
Workflow StepSample Enrichment
Quantity1 Kit
For Use With (Application)Mass Spectrometry
Unit Size40 reactions
Showing 2 of 2
MS-compatible—reagents directly compatible with in-solution peptide digestion
Sensitive—procedure successfully enriches low-abundance proteins (low ng range)
Low background—enriched samples contain minimal detergent residuals
Reduced antibody contamination—antibody biotinylation with streptavidin enrichment reduces contamination in the eluate when compared to other IP methods
Robust—procedure and reagents have been verified with numerous targets to ensure consistent enrichment of low-abundance proteins (ng range) with at least two peptides identified per protein

The Thermo Scientific Pierce MS-Compatible Magnetic IP Kit (Protein A/G) uses high-quality Pierce Protein A/G Magnetic Beads to provide wider flexibility of antibody capture than either Protein A or G alone. The Thermo Scientific Pierce MS-Compatible Magnetic IP Kit (Streptavidin) uses high-quality Pierce Streptavidin Magnetic Beads for use with biotinylated antibodies that may be purchased commercially or labeled using the Pierce Antibody Biotinylation Kit for IP. After the immunoprecipitation procedure, the target-enriched elution fraction is ready for in-solution tryptic digestion for LC-MS analysis without the need for gel purification, detergent removal, or desalting. Additionally, the reagents and procedures have been validated using both manual and automated magnetic separation.

Applications
• Enrichment of low-abundance targets to improve MS sensitivity
• Identification of target proteins that are not detectable by western blotting
• Quantitation of target proteins by LC-MS analysis
• Screening of antibodies for IP-MS

For Research Use Only. Not for use in diagnostic procedures.

Contents & Storage

Streptavidin Magnetic Beads, 1 mL
IP-MS Cell Lysis Buffer, 100 mL
IP-MS Wash Buffer A, 75 mL
IP-MS Wash Buffer B, 40 mL
IP-MS Elution Buffer, 6 mL

Store in refrigerator (2° to 8°C).

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text