Calcéine AM, colorants vert et bleu capables de pénétrer dans les cellules
Invitrogen™

Calcéine AM, colorants vert et bleu capables de pénétrer dans les cellules

La calcéine AM est un colorant cellulaire perméant qui peut être utilisé pour déterminer la viabilité cellulaire de la plupartAfficher plus
Have Questions?
Modifier l'affichagebuttonViewtableView
RéférenceType de produitQuantitéCouleur
C34852Calcéine verte, AM20 x 50 μgGreen
C3100MPCalcéine, AM20 x 50 μgGreen
C1430Calcéine, AM1 mgGreen
C3099Calcéine AM (solution à 1 mg/ml dans du DMSO sec)1 mLGreen
C1429Calcéine bleue, AM1 mgBlue
C481Calcéine, haute pureté100 mgGreen
Référence C34852
Prix (EUR)
669,65
Online Exclusive
736,00
Économisez 66,35 (9%)
Each
Type de produit:
Calcéine verte, AM
Quantité:
20 x 50 μg
Couleur:
Green
Prix (EUR)
669,65
Online Exclusive
736,00
Économisez 66,35 (9%)
Each
La calcéine AM est un colorant cellulaire perméant qui peut être utilisé pour déterminer la viabilité cellulaire de la plupart des cellules eucaryotes. Dans les cellules vivantes, la calcéine AM non fluorescente est convertie en calcéine à fluorescence verte, après hydrolyse d’ester acétoxyméthylique par estérases intracellulaires. Ce colorant est également disponible sous forme solide à raison de 1 mg (C-1430) à remettre en suspension dans du DMSO (C-3099). Pour une version à plus grande longueur d’onde de ce colorant, testez notre nouvelle calcéine AM rouge-orangée CellTrace (C-34851).
Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
Spécifications
Perméabilité cellulairePerméable aux cellules
Type de colorantAutre(s) étiquette(s) ou colorant(s)
FormatConditionnement spécial
Quantité20 x 50 μg
Type de réactifComposés de suivi cellulaire, réactifs de marquage cellulaire
Conditions d’expéditionTempérature ambiante, Température ambiante
Enzyme cibleEstérase
CouleurGreen
Emission495 nm
Excitation Wavelength Range515 nm
À utiliser avec (application)Traçage cellulaire, Traceur cellulaire
À utiliser avec (équipement)Microscope à fluorescence
Gamme de produitsCellTrace
Type de produitCalcéine verte, AM
Unit SizeEach
Contenu et stockage
Conserver au congélateur (-5 et -30°C).

Foire aux questions (FAQ)

I would like a dye to load in live cells such that it will self-quench at a high concentration, but if the cell dies, the dye will be released and unquenched. Do you have anything like that?

Yes. This is commonly done with calcein AM or FDA (fluorescein diacetate). These dyes will not fluoresce until cleaved by esterases. After modification by esterases and at very high concentrations, they will self-quench. Upon disruption of the plasma membrane, or cell death, the dye will be released into the extracellular medium, and become unquenched. Concentration and incubation time must be optimized to obtain adequate quenching.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I want to do a cell migration study for around 4 hours and need to fluorescently label the cells with a dye. What do you recommend?

Calcein, AM and FDA (fluorescein diaceate) are examples of some dyes used for this application. Since these dyes are not incorporated or covalently attached to any cellular components, they may have a short retention time as some cell types may actively efflux the dye out of the cells. The CellTracker and CellTrace dyes include either a mild thiol-reactive chloromethyl group or amine-reactive succinnimidyl ester group to allow for covalent binding to cellular components, providing for better retention. As with any reagent, one should empirically determine retention times for the cell type used.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I need a general cytoplasmic stain that does not overlap with the GFP in my cells. What do you recommend?

Calcein AM, a green dye, is typically used as a general cytoplasmic stain, but not recommended with GFP-positive cells. For GFP-expressing cells there are other colors available: Calcein Blue AM, Calcein Violet AM, and Calcein Red-Orange AM. The retention time of these dyes in live cells is dependent upon the inherent properties of the cell.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I labeled my cells with Calcein, AM, but when I imaged the next day, there was no fluorescence from Calcein. Why?

Calcein, AM is a good choice for cell tracking and as a general cytoplasmic stain. However, it doesn't bind to anything and may be actively pumped out of the cells within a couple hours, which is likely what happened. The retention of Calcein within live cells is dependent upon the inherent properties of the cell type and culture conditions.

For long-term imaging, you may wish to consider a reactive cytoplasmic stains such as CFDA, SE or the CellTracker and CellTrace dyes.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I stained two populations of cells, one with CellTracker Green and the other with CellTracker Red, but it looks like there may be crossover of the red dye to the green cells. What is going on?

One possibility is that there is spectral bleedthrough between the dyes. Be sure to check the single-color samples by imaging the red cells in green and imaging the green cells in red, using the optimal imaging settings for the other color. If you see bleedthrough with these controls, then you will have to reduce the dye label concentration to reduce the brightness of the dyes, or choose dyes that are farther apart spectrally. If the issue isn’t bleedthrough, another possibility is that the cells were not adequately washed after staining, allowing some unincorporated dye to remain and label the other cells after they were introduced. Extending washes and wash times should help with this.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Citations et références (633)

Citations et références
Abstract
Nitric oxide mediates natural polyphenol-induced Bcl-2 down-regulation and activation of cell death in metastatic B16 melanoma.
Authors:Ferrer P,Asensi M,Priego S,Benlloch M,Mena S,Ortega A,Obrador E,Esteve JM,Estrela JM
Journal:The Journal of biological chemistry
PubMed ID:17135264
Cloning and expression of murine sister of P-glycoprotein reveals a more discriminating transporter than MDR1/P-glycoprotein.
Authors:Lecureur V,Sun D,Hargrove P,Schuetz EG,Kim RB,Lan LB,Schuetz JD
Journal:Molecular pharmacology
PubMed ID:10617675
Deposition of laminin 5 by keratinocytes regulates integrin adhesion and signaling.
Authors:Nguyen BP,Gil SG,Carter WG
Journal:The Journal of biological chemistry
PubMed ID:10926936
Modification of the cytoplasmic domain of influenza virus hemagglutinin affects enlargement of the fusion pore.
Authors:Kozerski C,Ponimaskin E,Schroth-Diez B,Schmidt MF,Herrmann A
Journal:Journal of virology
PubMed ID:10906206
The fusion activity of chimeras of influenza virus hemagglutinin (HA) (from A/fpv/Rostock/34; subtype H7) with the transmembrane domain (TM) and/or cytoplasmic tail (CT) either from the nonviral, nonfusogenic T-cell surface protein CD4 or from the fusogenic Sendai virus F-protein was studied. Wild-type or chimeric HA was expressed in CV-1 cells ... More
Authors:
Journal:
PubMed ID:10891486